Patrick Herron
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Patrick Herron has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Kiril A. Streletzky
Department of Physics, Cleveland State University, Cleveland, Ohio 44115, United States
2 shared publications - Amber R. Titus
Cleveland Diagnostics, 3615 Superior Ave., Cleveland, OH 44114, USA
1 shared publication - Boris Y. Zaslavsky
Cleveland Diagnostics
1 shared publication - Pedro P. Madeira
Centro de Investigacao em Materiais Ceramicos e Compositos, Department of Chemistry, 3810-193 Aveiro, Portugal
1 shared publication - Vladimir Nikolaevich Uversky
Department of Molecular Medicine, University of South Florida, Tampa, United States, USA
1 shared publication
Latest Publications
- Open Access
- 12 March 2024
- Published by Royal Society of Chemistry (RSC) in Physical Chemistry Chemical Physics
- Vol. 26 (14) , 10546-10556
Effect of trimethylamine- N -oxide on the phase separation of aqueous polyethylene glycol-600-Dextran-75 two-phase systems
Trimethylamine- N -oxide enhances or suppresses phase separation in aqueous two-phase systems depending on the composition and concentration of phase forming components.
- 12 March 2024
- Published by Royal Society of Chemistry (RSC) in Physical Chemistry Chemical Physics
- Vol. 26 (14) , 10546-10556
Open AccessEffect of trimethylamine- N -oxide on the phase separation of aqueous polyethylene glycol-600-Dextran-75 two-phase systems
Trimethylamine- N -oxide enhances or suppresses phase separation in aqueous two-phase systems depending on the composition and concentration of phase forming components.
- Open Access
- 1 January 2023
- Published by AIP Publishing in Journal of Undergraduate Reports in Physics
- Vol. 33 (1)
Measuring dn/dc for Polysaccharide Microgels of Varying Crosslinking Density
Static light scattering (SLS) is a powerful, noninvasive experimental method that yields the molecular weight (average molecular weight, Mw), the size (radius of gyration, Rg), and the interactions between the scatters (the second virial coefficient, A2). However, proper SLS measurements require determination of the specific refractive index increment (dn/dc) for the samples studied. While tables of dn/dc values are available for various substances, they are not generally available for microgel particles, which in our case are crosslinked chains of an amphiphilic polymer. This paper is focused on measuring dn/dc for microgel samples of varying crosslinking concentrations. Microgel dn/dc values were found to be different from the value of the parent polymer given in literature and found to have a temperature dependence as well as a crosslinker concentration dependence at higher crosslinker concentrations. Using the measured values of microgel dn/dc instead of tabulated parent polymer values on estimates of microgel Mw, Rg, and A2 highlights the importance of direct dn/dc measurements for samples studied by SLS.
- 1 January 2023
- Published by AIP Publishing in Journal of Undergraduate Reports in Physics
- Vol. 33 (1)
Open AccessMeasuring dn/dc for Polysaccharide Microgels of Varying Crosslinking Density
Static light scattering (SLS) is a powerful, noninvasive experimental method that yields the molecular weight (average molecular weight, Mw), the size (radius of gyration, Rg), and the interactions between the scatters (the second virial coefficient, A2). However, proper SLS measurements require determination of the specific refractive index increment (dn/dc) for the samples studied. While tables of dn/dc values are available for various substances, they are not generally available for microgel particles, which in our case are crosslinked chains of an amphiphilic polymer. This paper is focused on measuring dn/dc for microgel samples of varying crosslinking concentrations. Microgel dn/dc values were found to be different from the value of the parent polymer given in literature and found to have a temperature dependence as well as a crosslinker concentration dependence at higher crosslinker concentrations. Using the measured values of microgel dn/dc instead of tabulated parent polymer values on estimates of microgel Mw, Rg, and A2 highlights the importance of direct dn/dc measurements for samples studied by SLS.