Chuxuan Guo
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Chuxuan Guo has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
- Jiajie Guo
Huazhong University of Science and Technology
9 shared publications - Yuchao Liu
Institute of Medical Equipment Science and Engineering, School of Mechanical Science and Engineering, State Key Laboratory of Intelligent Manufacturing Equipment and Technology, Huazhong University of Science and Technology, Wuhan, China
9 shared publications - Zijie Liu
Institute of Medical Equipment Science and Engineering, School of Mechanical Science and Engineering, State Key Laboratory of Intelligent Manufacturing Equipment and Technology, Huazhong University of Science and Technology, Wuhan, China
9 shared publications - Qining Wang
College of Engineering, Peking University, Beijing, China
6 shared publications - Xuan Wu
Robotics Laboratory, China Nanhu Academy of Electronics and Information Technology, Jiaxing, China
6 shared publications - Caihua Xiong
School of Medical Equipment Science and Engineering, Huazhong University of Science and Technology, Wuhan, China
5 shared publications
Latest Publications
- 1 September 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 73 (9) , 3225-3234
Longitudinal Monitoring of Full-Course Gait Rehabilitation Using Musculoskeletal Modeling and Muscle Coordination Analysis
Muscle coordination pattern can be disrupted by neural disorders and perceptual disturbance, leading to abnormal gaits. However, it is still unclear how neuro-muscular control regulates walking gaits through training and exercising due to lengthy rehabilitation periods and complicated musculoskeletal redundancies. This paper proposes a gait rehabilitation monitoring method based on muscle deformation to elucidate the evolution of muscle coordination during the full-course vertigo-gait rehabilitation. The proposed method is verified by musculoskeletal dynamics simulation and experimentally validated through immediate applications to five healthy subjects and five vertigo patients. The vertigo gaits were assessed by comparing with the normal gait of healthy subjects. For the first time, this paper reports experimental results and muscle coordination analysis throughout the full course of vertigo-gait rehabilitation. The findings reveal that the vertigo patient adjusts phase difference between the rectus femoris (RF) and medial gastrocnemius (MG) at toe-off, driving the knee and ankle joints to regulate foot-to-ground angle, thereby enhancing gait stability and walking efficiency. These results indicate that muscle deformations serve as an alternative quantity besides traditionally employed kinematic features, and the proposed wearable sensing method is expected to provide an effective tool for clinical gait assessment.
- 1 September 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 73 (9) , 3225-3234
Longitudinal Monitoring of Full-Course Gait Rehabilitation Using Musculoskeletal Modeling and Muscle Coordination Analysis
Muscle coordination pattern can be disrupted by neural disorders and perceptual disturbance, leading to abnormal gaits. However, it is still unclear how neuro-muscular control regulates walking gaits through training and exercising due to lengthy rehabilitation periods and complicated musculoskeletal redundancies. This paper proposes a gait rehabilitation monitoring method based on muscle deformation to elucidate the evolution of muscle coordination during the full-course vertigo-gait rehabilitation. The proposed method is verified by musculoskeletal dynamics simulation and experimentally validated through immediate applications to five healthy subjects and five vertigo patients. The vertigo gaits were assessed by comparing with the normal gait of healthy subjects. For the first time, this paper reports experimental results and muscle coordination analysis throughout the full course of vertigo-gait rehabilitation. The findings reveal that the vertigo patient adjusts phase difference between the rectus femoris (RF) and medial gastrocnemius (MG) at toe-off, driving the knee and ankle joints to regulate foot-to-ground angle, thereby enhancing gait stability and walking efficiency. These results indicate that muscle deformations serve as an alternative quantity besides traditionally employed kinematic features, and the proposed wearable sensing method is expected to provide an effective tool for clinical gait assessment.
- 29 May 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE/ASME Transactions on Mechatronics
- Vol. PP (10834435) , 1-8
Stretchable and Bendable Design of Pressure Sensor for Lower-Limb Motion Monitoring
Flexible pressure sensors provide exceptional compliance and portability, making them essential for soft robotics, wearable devices, and human–machine interaction. However, their performance is frequently compromised by multidimensional mechanical disturbances, particularly tensile and bending strains during installation and operation, which degrade sensing stability and measurement accuracy. To address this challenge, this paper introduces a capacitive flexible sensor incorporating a tailored wrinkle structure. Based on a strain-release mechanism, the design achieves high insensitivity to both stretching and bending while delivering a consistent and stable response to normal pressure. Experiments verify that the sensor maintains robust output unaffected by tensile strains up to 80% over curved surfaces (< 21.3 m-1), and preserves pressure sensitivity (< 5% deviation) under stretching up to 40%. Leveraging this mechanical decoupling capability, the proposed sensor captures plantar pressure and muscle deformations during lower-limb motions, where muscle deformation sensing was calibrated with ultrasound imaging. The sensor demonstrates excellent stability for plantar pressure sensing in dynamic motion environments and sensitively captures asymmetrical movement patterns through muscle deformation monitoring. This work provides a sensing strategy that ensures reliable quantitative measurement under multidimensionally coupled loads, offering a practical approach for applications ranging from rehabilitation assessment, medical treatment to human motor function enhancement.
- 29 May 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE/ASME Transactions on Mechatronics
- Vol. PP (10834435) , 1-8
Stretchable and Bendable Design of Pressure Sensor for Lower-Limb Motion Monitoring
Flexible pressure sensors provide exceptional compliance and portability, making them essential for soft robotics, wearable devices, and human–machine interaction. However, their performance is frequently compromised by multidimensional mechanical disturbances, particularly tensile and bending strains during installation and operation, which degrade sensing stability and measurement accuracy. To address this challenge, this paper introduces a capacitive flexible sensor incorporating a tailored wrinkle structure. Based on a strain-release mechanism, the design achieves high insensitivity to both stretching and bending while delivering a consistent and stable response to normal pressure. Experiments verify that the sensor maintains robust output unaffected by tensile strains up to 80% over curved surfaces (< 21.3 m-1), and preserves pressure sensitivity (< 5% deviation) under stretching up to 40%. Leveraging this mechanical decoupling capability, the proposed sensor captures plantar pressure and muscle deformations during lower-limb motions, where muscle deformation sensing was calibrated with ultrasound imaging. The sensor demonstrates excellent stability for plantar pressure sensing in dynamic motion environments and sensitively captures asymmetrical movement patterns through muscle deformation monitoring. This work provides a sensing strategy that ensures reliable quantitative measurement under multidimensionally coupled loads, offering a practical approach for applications ranging from rehabilitation assessment, medical treatment to human motor function enhancement.
- Open Access
- 1 October 2025
- Published by Wiley in Advanced Intelligent Systems
- Vol. 8 (2)
Soft Magnetic Sensor Array for Amphibious Measurement of 3D Muscle Deformation Distribution for Human Motion Recognition
Skeletal muscles are the primary power source for voluntary limb joint motions, thus muscle deformation (MD) is vital to reflect human motions. However, most sensors can capture only 1D MD features, and are suitable only for on‐land scenarios, leading to the under evaluation and under exploitation of MD sensing. This article develops a 4 × 4 soft magnetic sensor array (SMSA) to capture 3D MD distribution. Compared to solid structures, the used porous elastomer mitigates hydraulic pressure disturbances by half within 0–100‐m water depth, while sensitivity increases by 10 times. The SMSA has consistent amphibious measurements and about 200 ms faster response than inertial measurement units (IMUs). Mapping between 3D magnetic flux densities and deformations of elastomers is justified by calibration errors within 1% of full ranges. Experiments justify the proposed method in multiple environments, muscles, motions, and subjects. Average gait classification accuracy is 98.73%, and phase estimation error is 2.85% when using only one SMSA, which is better than existing commercial sensors (with 82.40% and 10.39% for one IMU, and 89.06% and 6.33% for one flexible resistive sensor array). The proposed method can contribute to muscle state monitoring for human–machine interaction, rehabilitation engineering, and sports science.
- 1 October 2025
- Published by Wiley in Advanced Intelligent Systems
- Vol. 8 (2)
Open AccessSoft Magnetic Sensor Array for Amphibious Measurement of 3D Muscle Deformation Distribution for Human Motion Recognition
Skeletal muscles are the primary power source for voluntary limb joint motions, thus muscle deformation (MD) is vital to reflect human motions. However, most sensors can capture only 1D MD features, and are suitable only for on‐land scenarios, leading to the under evaluation and under exploitation of MD sensing. This article develops a 4 × 4 soft magnetic sensor array (SMSA) to capture 3D MD distribution. Compared to solid structures, the used porous elastomer mitigates hydraulic pressure disturbances by half within 0–100‐m water depth, while sensitivity increases by 10 times. The SMSA has consistent amphibious measurements and about 200 ms faster response than inertial measurement units (IMUs). Mapping between 3D magnetic flux densities and deformations of elastomers is justified by calibration errors within 1% of full ranges. Experiments justify the proposed method in multiple environments, muscles, motions, and subjects. Average gait classification accuracy is 98.73%, and phase estimation error is 2.85% when using only one SMSA, which is better than existing commercial sensors (with 82.40% and 10.39% for one IMU, and 89.06% and 6.33% for one flexible resistive sensor array). The proposed method can contribute to muscle state monitoring for human–machine interaction, rehabilitation engineering, and sports science.
- 18 June 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-14
Muscle Deformation Sensing for Swimming Mode Identification and Continuous Phase Estimation With Two-Stage Network
Accurate recognition of human motion modes and continuous phases is crucial to exoskeleton control to provide proper assistance. However, harsh underwater environments severely restrict the study on swimming motion monitoring, where existing researches either focus on a single swimming mode or discrete phases, limiting underwater exoskeleton control. To address this limitation, this paper develops a two-stage network consisting of one mode classifier (1st stage) and four phase regressors (2nd stage), where muscle deformation features are used instead of traditional joint kinematics. Swimming tests are conducted on nine subjects with four modes at three frequencies. Effectiveness of the proposed method is justified by mode identification accuracy of 99.72% and phase estimation error of 3.92%, where the error is 52.89% smaller than that in the traditional time-based estimation method. This paper is the first to simultaneously recognize the swimming mode and the continuous phase, which is valuable to adapt the smooth exoskeleton assistance to harsh underwater environment and multimodal motion scenarios.
- 18 June 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-14
Muscle Deformation Sensing for Swimming Mode Identification and Continuous Phase Estimation With Two-Stage Network
Accurate recognition of human motion modes and continuous phases is crucial to exoskeleton control to provide proper assistance. However, harsh underwater environments severely restrict the study on swimming motion monitoring, where existing researches either focus on a single swimming mode or discrete phases, limiting underwater exoskeleton control. To address this limitation, this paper develops a two-stage network consisting of one mode classifier (1st stage) and four phase regressors (2nd stage), where muscle deformation features are used instead of traditional joint kinematics. Swimming tests are conducted on nine subjects with four modes at three frequencies. Effectiveness of the proposed method is justified by mode identification accuracy of 99.72% and phase estimation error of 3.92%, where the error is 52.89% smaller than that in the traditional time-based estimation method. This paper is the first to simultaneously recognize the swimming mode and the continuous phase, which is valuable to adapt the smooth exoskeleton assistance to harsh underwater environment and multimodal motion scenarios.
- 17 June 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE/ASME Transactions on Mechatronics
- Vol. 30 (6) , 7346-7358
Durable and Flexible Magnetoelastic Sensing for Plantar Distributions of Normal and Shear Loads
Tri-axial reaction forces (TRF), which support body mass and provide dynamic propulsion, are critical to improve motion stability, gait transitions, and energy efficiency in legged motions of both humans and robots. The accurate and robust sensing of TRF presents significant challenges due to the cyclic and high-impact loads. Existing commercial sensors with rigid encapsulation have a heavy weight and poor wearability, while flexible sensors with conformal capability are susceptible to damage under cyclic impacts due to complex structure and stress concentration between flexible and hard interfaces. This article proposes a flexible magnetoelastic sensing method that couples three-dimensional elastomer deformations with magnetic flux intensities to capture tri-axial load distributions. The locally-stiffened design mitigates stress concentration at the interfaces among soft elastomer, flexible substrate, and rigid chips. The plantar load sensing array is developed to measure loads up to 116, 113, and 433 kPa in the x-, y-, and z-axes, respectively, with durability validated by the 150 000-cycle compression test and 9-month clinical gait monitoring. The proposed method is illustrated with an immediate application to gait pattern identification, and it is anticipated to contribute to tri-axial force sensing in various scenarios, including but not limited to rehabilitation gait monitoring, legged robot navigation, and human–robot interaction.
- 17 June 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE/ASME Transactions on Mechatronics
- Vol. 30 (6) , 7346-7358
Durable and Flexible Magnetoelastic Sensing for Plantar Distributions of Normal and Shear Loads
Tri-axial reaction forces (TRF), which support body mass and provide dynamic propulsion, are critical to improve motion stability, gait transitions, and energy efficiency in legged motions of both humans and robots. The accurate and robust sensing of TRF presents significant challenges due to the cyclic and high-impact loads. Existing commercial sensors with rigid encapsulation have a heavy weight and poor wearability, while flexible sensors with conformal capability are susceptible to damage under cyclic impacts due to complex structure and stress concentration between flexible and hard interfaces. This article proposes a flexible magnetoelastic sensing method that couples three-dimensional elastomer deformations with magnetic flux intensities to capture tri-axial load distributions. The locally-stiffened design mitigates stress concentration at the interfaces among soft elastomer, flexible substrate, and rigid chips. The plantar load sensing array is developed to measure loads up to 116, 113, and 433 kPa in the x-, y-, and z-axes, respectively, with durability validated by the 150 000-cycle compression test and 9-month clinical gait monitoring. The proposed method is illustrated with an immediate application to gait pattern identification, and it is anticipated to contribute to tri-axial force sensing in various scenarios, including but not limited to rehabilitation gait monitoring, legged robot navigation, and human–robot interaction.
- 5 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-10
Muscle-Joint Feature Fusion for Swimming Pattern Recognition With 1D-CNN Classifier
Swimming pattern recognition plays an important role in underwater wearable robot control and competitive sports training. However, serious disturbances of harsh underwater environments result in few available sensing methods, and existing single–mode sensing inherently limits the efficiency of swimming monitoring. This paper combines muscle deformations measured by flexible capacitive sensors with limb joint rotations by inertial measurement units. Heatmaps and polar coordinate systems are used to exhibit differences of cyclic features in four strokes. The t–SNE method is used to convert high–dimensional fusion features to a 2D plane for visualization. Using 1D–CNN classifier for swimming pattern recognition at three kicking frequencies, effectiveness of the method was experimentally validated by nine subjects with the average accuracy of 97.9%, while that in single sensing modality is 82.6% with muscle deformations and 85.9% with limb rotations. To the best of our knowledge, this paper is the first to use multimodal fusion for swimming motion monitoring, and is expected to enhance underwater wearable sensing devices for human-centered robotics and sports science.
- 5 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-10
Muscle-Joint Feature Fusion for Swimming Pattern Recognition With 1D-CNN Classifier
Swimming pattern recognition plays an important role in underwater wearable robot control and competitive sports training. However, serious disturbances of harsh underwater environments result in few available sensing methods, and existing single–mode sensing inherently limits the efficiency of swimming monitoring. This paper combines muscle deformations measured by flexible capacitive sensors with limb joint rotations by inertial measurement units. Heatmaps and polar coordinate systems are used to exhibit differences of cyclic features in four strokes. The t–SNE method is used to convert high–dimensional fusion features to a 2D plane for visualization. Using 1D–CNN classifier for swimming pattern recognition at three kicking frequencies, effectiveness of the method was experimentally validated by nine subjects with the average accuracy of 97.9%, while that in single sensing modality is 82.6% with muscle deformations and 85.9% with limb rotations. To the best of our knowledge, this paper is the first to use multimodal fusion for swimming motion monitoring, and is expected to enhance underwater wearable sensing devices for human-centered robotics and sports science.
- 4 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-11
Human Walking Gait Transition Monitoring Using a Muscle Deformation Synergy Method
Gait pattern transition is important for wearable robot control to assist human walking on various terrains. The mismatch between human and machine motions during gait transitions poses challenges to human-robot interaction, leading to undesirable robotic assistance and high impacts or even damages to the human body. This paper proposes a gait transition monitoring method based on wearable sensing of muscle deformation synergy during multi-pattern natural motions. The cyclic features of different gaits, as depicted in the polar coordinate diagrams, facilitate the use of neural networks for pattern identification and phase estimation during gait transition. The proposed method has demonstrated adaptability to multiple natural gaits, as validated by the consistent transition phase (standard deviation ± 3.8%) and duration (standard deviation ± 3.5%) of nine subjects observed by four transition modes across normal walking and stair ascent / decent motions. This research is expected to provide valuable guidelines to develop robotic assistance control and improve human-machine coordination during gait transition.
- 4 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-11
Human Walking Gait Transition Monitoring Using a Muscle Deformation Synergy Method
Gait pattern transition is important for wearable robot control to assist human walking on various terrains. The mismatch between human and machine motions during gait transitions poses challenges to human-robot interaction, leading to undesirable robotic assistance and high impacts or even damages to the human body. This paper proposes a gait transition monitoring method based on wearable sensing of muscle deformation synergy during multi-pattern natural motions. The cyclic features of different gaits, as depicted in the polar coordinate diagrams, facilitate the use of neural networks for pattern identification and phase estimation during gait transition. The proposed method has demonstrated adaptability to multiple natural gaits, as validated by the consistent transition phase (standard deviation ± 3.8%) and duration (standard deviation ± 3.5%) of nine subjects observed by four transition modes across normal walking and stair ascent / decent motions. This research is expected to provide valuable guidelines to develop robotic assistance control and improve human-machine coordination during gait transition.
- 30 May 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 24 (14) , 23173-23182
Continuous Gait Phase Estimation by Muscle Deformations With Speed and Ramp Adaptability
Accurate estimation of gait phases is crucial in controlling wearable robots designed to restore or enhance human walking capabilities. Asynchronous human-machine motions can lead to reduced efficiency, increased interaction loads, and potential harm to the human body. Variations in walking speeds and terrain ramps pose additional challenges to continuous phase estimation. This paper presents a novel synergy method based on muscle deformations measured by flexible wearable sensors to dynamically monitor gait phases while adapting to changes in speed and terrain ramp. Polar coordinate diagrams are used to elucidate the cyclic features of joint angles and muscle deformations during walking. The consistency of muscle deformation synergy is studied to build a phase estimation model, with parameters being determined by neural network algorithms. The average root-mean-square error for the estimated phase is less than 4.4% within a speed range of 3 to 6 km/h and less than 8.8% in a ramp range of 0 to 10°. Muscle deformation presents a viable alternative in scenarios involving changes in speed, outperforming joint kinematics in gait phase estimation amidst variations in ramp inclinations. The proposed unified muscle synergy model, adaptable across a wide spectrum of walking speeds and ramp inclinations, holds promise for enhancing human-machine coordination for robotic assistance and rehabilitation.
- 30 May 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 24 (14) , 23173-23182
Continuous Gait Phase Estimation by Muscle Deformations With Speed and Ramp Adaptability
Accurate estimation of gait phases is crucial in controlling wearable robots designed to restore or enhance human walking capabilities. Asynchronous human-machine motions can lead to reduced efficiency, increased interaction loads, and potential harm to the human body. Variations in walking speeds and terrain ramps pose additional challenges to continuous phase estimation. This paper presents a novel synergy method based on muscle deformations measured by flexible wearable sensors to dynamically monitor gait phases while adapting to changes in speed and terrain ramp. Polar coordinate diagrams are used to elucidate the cyclic features of joint angles and muscle deformations during walking. The consistency of muscle deformation synergy is studied to build a phase estimation model, with parameters being determined by neural network algorithms. The average root-mean-square error for the estimated phase is less than 4.4% within a speed range of 3 to 6 km/h and less than 8.8% in a ramp range of 0 to 10°. Muscle deformation presents a viable alternative in scenarios involving changes in speed, outperforming joint kinematics in gait phase estimation amidst variations in ramp inclinations. The proposed unified muscle synergy model, adaptable across a wide spectrum of walking speeds and ramp inclinations, holds promise for enhancing human-machine coordination for robotic assistance and rehabilitation.
- 18 December 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-12
Wearable Sensing for Breaststroke Phase Monitoring With Lower Limb Muscle-Joint Synergy
Motivated by the need for underwater exoskeleton control, swimming phase monitoring is critical to adjust robotic assistance to human motions. However, harsh underwater environments bring in challenges of poor robustness and serious disturbances to the few available sensing methods leading to coarse phase segmentation. Given skeletal muscle activation for limb joint motions, this paper proposes a muscle-joint synergy method to combine muscle mechanics captured by a novel capacitive sensor with joint kinematics by traditional inertial measurements. Development of the wearable sensing system is provided with details on design, fabrication and assembly. The muscle-joint synergy model is rigorously formulated and experimentally validated with breaststroke data for the first time. Immediate applications are illustrated with discrete mode identification and continuous phase monitoring, justifying the robustness of the proposed method to various artificial intelligent algorithms and different tested subjects. This work is anticipated to be valuable to unveil the mechanism of human natural motions for human-centered robotics, sport science and rehabilitation engineering in the future.
- 18 December 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-12
Wearable Sensing for Breaststroke Phase Monitoring With Lower Limb Muscle-Joint Synergy
Motivated by the need for underwater exoskeleton control, swimming phase monitoring is critical to adjust robotic assistance to human motions. However, harsh underwater environments bring in challenges of poor robustness and serious disturbances to the few available sensing methods leading to coarse phase segmentation. Given skeletal muscle activation for limb joint motions, this paper proposes a muscle-joint synergy method to combine muscle mechanics captured by a novel capacitive sensor with joint kinematics by traditional inertial measurements. Development of the wearable sensing system is provided with details on design, fabrication and assembly. The muscle-joint synergy model is rigorously formulated and experimentally validated with breaststroke data for the first time. Immediate applications are illustrated with discrete mode identification and continuous phase monitoring, justifying the robustness of the proposed method to various artificial intelligent algorithms and different tested subjects. This work is anticipated to be valuable to unveil the mechanism of human natural motions for human-centered robotics, sport science and rehabilitation engineering in the future.