Qinyun Tang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Qinyun Tang has a total of 25 co-authors. Here are the top co-authors by number of shared publications:
- Liquan Wang
College of Mechanical and Electrical Engineering, Harbin Engineering University, Harbin, China
4 shared publications - Mingxuan Ding
College of Mechanical and Electrical Engineering, Harbin Engineering University, Harbin, China
4 shared publications - Gang Wang
National Key Laboratory of Autonomous Marine Vehicle Technology, Harbin Engineering University, Harbin, China
3 shared publications - Kaixin Liu
College of Shipbuilding Engineering, Harbin Engineering University, Harbin 150001, China
3 shared publications - Xi Chen
College of Mechanical and Electrical Engineering, Heilongjiang Institute of Technology, Harbin 150050, China
3 shared publications - Yingxuan Li
Harbin Engn Univ, Coll Mech & Elect Engn, Harbin 150001, Peoples R China
3 shared publications
Latest Publications
- 22 October 2024
- Published by Elsevier in Robotics and Autonomous Systems
- Vol. 183
Advancements in amphibious robot navigation through wheeled odometer uncertainty extension and distributed information fusion
- 22 October 2024
- Published by Elsevier in Robotics and Autonomous Systems
- Vol. 183
Advancements in amphibious robot navigation through wheeled odometer uncertainty extension and distributed information fusion
- Open Access
- 17 April 2024
- Published by MDPI AG in Journal of Marine Science and Engineering
- Vol. 12 (4) , 662
Study on the Adsorption Performance of a Vortex Suction Cup under Varying Diameters of Underwater Structure Tubes
In certain precision work scenarios, underwater robots require the ability to adhere to surfaces in order to perform tasks effectively. An efficient and stable suction device plays a pivotal role in the functionality of such underwater robots. The vortex suction cup, distinguished by its uncomplicated design, high suction efficiency, and capability for non-contact adhesion, holds significant promise for integration into underwater robotic systems. This paper presents a novel design for a vortex suction cup and investigates its suction force and torque when encountering surfaces with varying curvature radii using Computational Fluid Dynamics (CFD) simulations and experimental testing. These findings offer valuable insights for the development of robots capable of adapting to underwater structures of different dimensions. Results from both experiments and simulations indicate that reducing the curvature radius of the adhered surface results in a decrease in suction force and an increase in torque exerted on the suction cup. As the adhered surface transitions from flat to a curvature radius of 150 mm, the adhesion force of our proposed vortex suction cup decreases by approximately 10%, while the torque increases by approximately 20% to 30%. Consequently, the adhesion efficiency of the suction cup decreases by about 25% to 30%.
- 17 April 2024
- Published by MDPI AG in Journal of Marine Science and Engineering
- Vol. 12 (4) , 662
Open AccessStudy on the Adsorption Performance of a Vortex Suction Cup under Varying Diameters of Underwater Structure Tubes
In certain precision work scenarios, underwater robots require the ability to adhere to surfaces in order to perform tasks effectively. An efficient and stable suction device plays a pivotal role in the functionality of such underwater robots. The vortex suction cup, distinguished by its uncomplicated design, high suction efficiency, and capability for non-contact adhesion, holds significant promise for integration into underwater robotic systems. This paper presents a novel design for a vortex suction cup and investigates its suction force and torque when encountering surfaces with varying curvature radii using Computational Fluid Dynamics (CFD) simulations and experimental testing. These findings offer valuable insights for the development of robots capable of adapting to underwater structures of different dimensions. Results from both experiments and simulations indicate that reducing the curvature radius of the adhered surface results in a decrease in suction force and an increase in torque exerted on the suction cup. As the adhered surface transitions from flat to a curvature radius of 150 mm, the adhesion force of our proposed vortex suction cup decreases by approximately 10%, while the torque increases by approximately 20% to 30%. Consequently, the adhesion efficiency of the suction cup decreases by about 25% to 30%.
- 15 March 2024
- Published by Elsevier in Ocean Engineering
- Vol. 300
Study on the performance of vortex suction cup for an underwater inspection robot
- 15 March 2024
- Published by Elsevier in Ocean Engineering
- Vol. 300
Study on the performance of vortex suction cup for an underwater inspection robot
- Open Access
- 29 January 2024
- Published by MDPI AG in Biomimetics
- Vol. 9 (2) , 81
Effect of Bionic Crab Shell Attitude Parameters on Lift and Drag in a Flow Field
Underwater bionic-legged robots encounter significant challenges in attitude, velocity, and positional control due to lift and drag in water current environments, making it difficult to balance operational efficiency with motion stability. This study delves into the hydrodynamic properties of a bionic crab robot’s shell, drawing inspiration from the sea crab’s motion postures. It further refines the robot’s underwater locomotion strategy based on these insights. Initially, the research involved collecting attitude data from crabs during underwater movement through biological observation. Subsequently, hydrodynamic simulations and experimental validations of the bionic shell were conducted, examining the impact of attitude parameters on hydrodynamic performance. The findings reveal that the transverse angle predominantly influences lift and drag. Experiments in a test pool with a crab-like robot, altering transverse angles, demonstrated that increased transverse angles enhance the robot’s underwater walking efficiency, stability, and overall performance.
- 29 January 2024
- Published by MDPI AG in Biomimetics
- Vol. 9 (2) , 81
Open AccessEffect of Bionic Crab Shell Attitude Parameters on Lift and Drag in a Flow Field
Underwater bionic-legged robots encounter significant challenges in attitude, velocity, and positional control due to lift and drag in water current environments, making it difficult to balance operational efficiency with motion stability. This study delves into the hydrodynamic properties of a bionic crab robot’s shell, drawing inspiration from the sea crab’s motion postures. It further refines the robot’s underwater locomotion strategy based on these insights. Initially, the research involved collecting attitude data from crabs during underwater movement through biological observation. Subsequently, hydrodynamic simulations and experimental validations of the bionic shell were conducted, examining the impact of attitude parameters on hydrodynamic performance. The findings reveal that the transverse angle predominantly influences lift and drag. Experiments in a test pool with a crab-like robot, altering transverse angles, demonstrated that increased transverse angles enhance the robot’s underwater walking efficiency, stability, and overall performance.
- Open Access
- 19 December 2023
- Published by MDPI AG in Journal of Marine Science and Engineering
- Vol. 12 (1) , 10
Leg Mechanism Design and Motion Performance Analysis for an Amphibious Crab-like Robot
Bionic-legged robots draw inspiration from animal locomotion methods and structures, demonstrating the potential to traverse irregular and unstructured environments. The ability of Portunus trituberculatus (Portunus) to run flexibly and quickly in amphibious environments inspires the design of systems and locomotion methods for amphibious robots. This research describes an amphibious crab-like robot based on Portunus and designs a parallel leg mechanism for the robot based on biological observations. The research creates the group and sequential gait commonly used in multiped robots combined with the form of the robot’s leg mechanism arrangement. This research designed the parallel leg mechanism and modeled its dynamics. Utilizing the outcomes of the dynamics modeling, we calculate the force and torque exerted on each joint of the leg mechanism during group gait and sequential gait when the robot is moving with a load. This analysis aims to assess the performance of the robot’s motion. Finally, a series of performance evaluation experiments are conducted on land and underwater, which show that the amphibious crab-like robot has good walking performance. The crab-like robot can perform forward, backward, left, and right walking well using group and sequential gaits. Simultaneously, the crab-like robot showcases faster movement in group gaits and a more substantial load capacity in sequential gaits.
- 19 December 2023
- Published by MDPI AG in Journal of Marine Science and Engineering
- Vol. 12 (1) , 10
Open AccessLeg Mechanism Design and Motion Performance Analysis for an Amphibious Crab-like Robot
Bionic-legged robots draw inspiration from animal locomotion methods and structures, demonstrating the potential to traverse irregular and unstructured environments. The ability of Portunus trituberculatus (Portunus) to run flexibly and quickly in amphibious environments inspires the design of systems and locomotion methods for amphibious robots. This research describes an amphibious crab-like robot based on Portunus and designs a parallel leg mechanism for the robot based on biological observations. The research creates the group and sequential gait commonly used in multiped robots combined with the form of the robot’s leg mechanism arrangement. This research designed the parallel leg mechanism and modeled its dynamics. Utilizing the outcomes of the dynamics modeling, we calculate the force and torque exerted on each joint of the leg mechanism during group gait and sequential gait when the robot is moving with a load. This analysis aims to assess the performance of the robot’s motion. Finally, a series of performance evaluation experiments are conducted on land and underwater, which show that the amphibious crab-like robot has good walking performance. The crab-like robot can perform forward, backward, left, and right walking well using group and sequential gaits. Simultaneously, the crab-like robot showcases faster movement in group gaits and a more substantial load capacity in sequential gaits.