Mohammad Jahangir Alam
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Mohammad Jahangir Alam has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Omar Farrok
Department of Electrical and Electronic Engineering, Ahsanullah University of Science and Technology, Dhaka 1208, Bangladesh
3 shared publications - Selim Molla
Bangladesh University of Engineering and Technology
2 shared publications Adnan Kiber
Department of Applied Physics and Electronics, University of Dhaka, Dhaka, Bangladesh
1 shared publicationGa Zakaria
Gummerbeach, Cologne University Teaching Hospital, Gummerbeach, Germany
1 shared publicationKamila Afroj
Institute of Nuclear Medicine & Ultrasound, Bangladesh Atomic Energy Commission, Dhaka
1 shared publicationKs Rabbani
Department of Physics, University of Dhaka, Dhaka
1 shared publication
Latest Publications
- 16 October 2024
- Published by Elsevier in Renewable Energy
- Vol. 237
Sustainable solution to the critical challenges of an oceanic wave farm for maximizing power generation
- 16 October 2024
- Published by Elsevier in Renewable Energy
- Vol. 237
Sustainable solution to the critical challenges of an oceanic wave farm for maximizing power generation
- 15 December 2023
- Published by Elsevier in Renewable and Sustainable Energy Reviews
- Vol. 191
Electrical energy and the environment: Prospects and upcoming challenges of the World's top leading countries
- 15 December 2023
- Published by Elsevier in Renewable and Sustainable Energy Reviews
- Vol. 191
Electrical energy and the environment: Prospects and upcoming challenges of the World's top leading countries
- Open Access
Effect of Dispersion and Different Carrier Transitions on Absorption Characteristics of GaAs
One of the basic optoelectronic characteristics is the absorption of any optoelectronic device or material. We present the characteristics of pure GaAs and the deviation of ideal spectra. Due to crystal defects, vacancies, impurities, etc., energy states exist in the semiconductor other than the allowed bands (conduction and valence bands). In this research, the effect of transitions between these states on absorption spectra and how the absorption coefficients change with the density and location of those states are analyzed numerically. Among the cases of 0.07 eV, 0.12 eV, and 0.17 eV with the density of 2%, 5%, 10%, 20%, and 30%, the minimum deviation occurs for the states located 0.07 eV below the conduction band and when the energy states have the minimum density of 2% and the deviation increases for the cases of 0.12 eV and 0.17 eV with higher densities.
Open AccessEffect of Dispersion and Different Carrier Transitions on Absorption Characteristics of GaAs
One of the basic optoelectronic characteristics is the absorption of any optoelectronic device or material. We present the characteristics of pure GaAs and the deviation of ideal spectra. Due to crystal defects, vacancies, impurities, etc., energy states exist in the semiconductor other than the allowed bands (conduction and valence bands). In this research, the effect of transitions between these states on absorption spectra and how the absorption coefficients change with the density and location of those states are analyzed numerically. Among the cases of 0.07 eV, 0.12 eV, and 0.17 eV with the density of 2%, 5%, 10%, 20%, and 30%, the minimum deviation occurs for the states located 0.07 eV below the conduction band and when the energy states have the minimum density of 2% and the deviation increases for the cases of 0.12 eV and 0.17 eV with higher densities.
- Open Access
- 20 April 2013
- Published by Bangladesh Academy of Sciences in Bangladesh Journal of Medical Physics
- Vol. 4 (1) , 43-49
Quality Assurance of Dose Distribution of Photon Beam Planning by Anisotropic Analytical Algorithm (AAA)
A three dimensional treatment planning system has been installed in the Oncology Center, Bangladesh. This system is based on the Anisotropic Analytical Algorithm (AAA). The aim of this study is to verify the validity of photon dose distribution which is calculated by this treatment planning system by comparing it with measured photon beam data in real water phantom. To do this verification, a quality assurance program, consisting of six tests, was performed. In this program, both the calculated output factors and dose at different conditions were compared with the measurement. As a result of that comparison, we found that the calculated output factor was in excellent agreement with the measured factors. Doses at depths beyond the depth of maximum dose calculated on-axis or off-axis in both the fields or penumbra region were found in good agreement with the measured dose under all conditions of energy, SSD and field size, for open and wedged fields. In the build up region, calculated and measured doses only agree (with a difference 2.0%) for field sizes > 5 × 5 cm2 up to 25 × 25 cm2. For smaller fields, the difference was higher than 2.0% because of the difficulty in dosimetry in that region. Dose calculation using treatment planning system based on the Anisotropic Analytical Algorithm (AAA) is accurate enough for clinical use except when calculating dose at depths above maximum dose for small field size.DOI: http://dx.doi.org/10.3329/bjmp.v4i1.14686 Bangladesh Journal of Medical Physics Vol.4 No.1 2011 43-49
- 20 April 2013
- Published by Bangladesh Academy of Sciences in Bangladesh Journal of Medical Physics
- Vol. 4 (1) , 43-49
Open AccessQuality Assurance of Dose Distribution of Photon Beam Planning by Anisotropic Analytical Algorithm (AAA)
A three dimensional treatment planning system has been installed in the Oncology Center, Bangladesh. This system is based on the Anisotropic Analytical Algorithm (AAA). The aim of this study is to verify the validity of photon dose distribution which is calculated by this treatment planning system by comparing it with measured photon beam data in real water phantom. To do this verification, a quality assurance program, consisting of six tests, was performed. In this program, both the calculated output factors and dose at different conditions were compared with the measurement. As a result of that comparison, we found that the calculated output factor was in excellent agreement with the measured factors. Doses at depths beyond the depth of maximum dose calculated on-axis or off-axis in both the fields or penumbra region were found in good agreement with the measured dose under all conditions of energy, SSD and field size, for open and wedged fields. In the build up region, calculated and measured doses only agree (with a difference 2.0%) for field sizes > 5 × 5 cm2 up to 25 × 25 cm2. For smaller fields, the difference was higher than 2.0% because of the difficulty in dosimetry in that region. Dose calculation using treatment planning system based on the Anisotropic Analytical Algorithm (AAA) is accurate enough for clinical use except when calculating dose at depths above maximum dose for small field size.DOI: http://dx.doi.org/10.3329/bjmp.v4i1.14686 Bangladesh Journal of Medical Physics Vol.4 No.1 2011 43-49
- Open Access
- 15 September 2008
- Published by Bangladesh Academy of Sciences in Bangladesh Medical Research Council Bulletin
- Vol. 33 (3) , 92-97
A modified formula for defining tissue phantom ratio of photon beams
Tissue phantom ratio (TPR), for square fields of various dimensions has been determined at varying depths in water. The dose in water has been measured at a fixed source-to-surface distance (SSD) of 100 cm and reference depth of 5 cm for 6 MV photon beam of Siemens Linear Accelerator Primus II in German Cancer Research Center (DKFZ), Heidelberg, Germany. A modified formula has been developed to calculate the TPR value for isocentric treatment. The present article describes the conversion of the measured data values into a comprehensive and consistent data set by the modified formula, that gives the TPR from Percentage Depth Dose (PDD) with depth as a function of field sizes from 10 mm x 10 mm up to 300 mm x 300 mm) and depth (from 0 mm to 300 mm). DOI = 10.3329/bmrcb.v33i3.1140 Bangladesh Med Res Counc Bull 2007; 33: 92-97
- 15 September 2008
- Published by Bangladesh Academy of Sciences in Bangladesh Medical Research Council Bulletin
- Vol. 33 (3) , 92-97
Open AccessA modified formula for defining tissue phantom ratio of photon beams
Tissue phantom ratio (TPR), for square fields of various dimensions has been determined at varying depths in water. The dose in water has been measured at a fixed source-to-surface distance (SSD) of 100 cm and reference depth of 5 cm for 6 MV photon beam of Siemens Linear Accelerator Primus II in German Cancer Research Center (DKFZ), Heidelberg, Germany. A modified formula has been developed to calculate the TPR value for isocentric treatment. The present article describes the conversion of the measured data values into a comprehensive and consistent data set by the modified formula, that gives the TPR from Percentage Depth Dose (PDD) with depth as a function of field sizes from 10 mm x 10 mm up to 300 mm x 300 mm) and depth (from 0 mm to 300 mm). DOI = 10.3329/bmrcb.v33i3.1140 Bangladesh Med Res Counc Bull 2007; 33: 92-97