Gabriela Knippelberg Bifano Manea
Gabriela Knippelberg Bifano Manea has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
- Elcio Cruz de Oliveira
Postgraduate Programme in Metrology, Pontifical Catholic University of Rio de Janeiro
3 shared publications - Mauro Alves Correa de Camargo
Measurement and Quality Management, Petrobras Transporte S.A., Rio de Janeiro 20090-901, Brazil
2 shared publications - Rainerio Escalfoni Junior
Research Center, Petrobras S.A., Rio de Janeiro 21941-915, Brazil
1 shared publication - Vanusa Bueno Freire
Logistics, Logistics Operations, Product Quality Management, Petrobras S.A., Rio de Janeiro 20231-030, Brazil
1 shared publication
Latest Publications
- Open Access
Analytical Compatibility between Various Techniques for Determining Dissolved Manganese in Produced Water
Petroleum-produced water is the primary effluent generated during the oil extraction process, presenting high flow rates, and containing a series of chemical components that are harmful to the environment, such as dissolved manganese. The proof of metrological compatibility between laboratories and different test methods or techniques is an analytical challenge when complying with environmental laws and regulations, which is the aim of this study. The first step of this study was to compare the results of manganese content in real test samples of produced water between some laboratories that used different test methods, that is, flame atomic absorption spectrophotometry, inductively coupled plasma optical emission spectroscopy, and inductively coupled plasma mass spectrometry. Based on one-way analysis of variance, systematic errors were found. The following step was to visit a specific lab, where one could confirm the relevance of the wavelength parameters, operating conditions for the view configuration, and effects of the saline matrices. Finally, a compatibility assessment between the reference laboratory and a new laboratory, which implemented and validated its analytical methodology based on these analytical adjustments, and the experiences and lessons learned in the previous step, was undertaken by a paired t-test.
Open AccessAnalytical Compatibility between Various Techniques for Determining Dissolved Manganese in Produced Water
Petroleum-produced water is the primary effluent generated during the oil extraction process, presenting high flow rates, and containing a series of chemical components that are harmful to the environment, such as dissolved manganese. The proof of metrological compatibility between laboratories and different test methods or techniques is an analytical challenge when complying with environmental laws and regulations, which is the aim of this study. The first step of this study was to compare the results of manganese content in real test samples of produced water between some laboratories that used different test methods, that is, flame atomic absorption spectrophotometry, inductively coupled plasma optical emission spectroscopy, and inductively coupled plasma mass spectrometry. Based on one-way analysis of variance, systematic errors were found. The following step was to visit a specific lab, where one could confirm the relevance of the wavelength parameters, operating conditions for the view configuration, and effects of the saline matrices. Finally, a compatibility assessment between the reference laboratory and a new laboratory, which implemented and validated its analytical methodology based on these analytical adjustments, and the experiences and lessons learned in the previous step, was undertaken by a paired t-test.
- Open Access
Design of Experiments for Evaluating the Relevance of Change in Test Method for Kinematic Viscosity of Opaque Oils
Viscosity is a physicochemical property that evaluates the resistance that fuel offers to flow, influencing the engine’s operation and combustion process. Its control is aimed at good fuel atomization and the preservation of lubricating characteristics. Changes in viscosity can lead to wear on various parts of the engine. Viscometers typically measure the viscosity of fuels in the oil and gas industry. These instruments can measure the time it takes for a fluid to move a given distance through a pipe or the time it takes for an object of a given size and density to pass through the liquid. The traditional test method, ASTM D445, differentiates the procedure for opaque liquids from transparent ones; that is, it requires a warm-up of the sample between 60 °C and 65 °C for 1 h. This additional step can overload laboratory routines, although it is not guaranteed to have a metrologically significant effect on the final result. Thus, this study evaluated the relevance of complying with this step in the test method for the kinematic viscosity of opaque liquids using a 32 factorial experimental design. Based on the F test, p-value, confidence intervals, and percentage contribution of the sum of squares approaches concerning the regression analysis, one concluded that the warm-up time was not a relevant factor in the kinematic viscosity, specifically of very low sulphur fuel oil, Brazilian fuel oil, and atmospheric residue diluted with diesel oil, which are fluids at room temperature.
Open AccessDesign of Experiments for Evaluating the Relevance of Change in Test Method for Kinematic Viscosity of Opaque Oils
Viscosity is a physicochemical property that evaluates the resistance that fuel offers to flow, influencing the engine’s operation and combustion process. Its control is aimed at good fuel atomization and the preservation of lubricating characteristics. Changes in viscosity can lead to wear on various parts of the engine. Viscometers typically measure the viscosity of fuels in the oil and gas industry. These instruments can measure the time it takes for a fluid to move a given distance through a pipe or the time it takes for an object of a given size and density to pass through the liquid. The traditional test method, ASTM D445, differentiates the procedure for opaque liquids from transparent ones; that is, it requires a warm-up of the sample between 60 °C and 65 °C for 1 h. This additional step can overload laboratory routines, although it is not guaranteed to have a metrologically significant effect on the final result. Thus, this study evaluated the relevance of complying with this step in the test method for the kinematic viscosity of opaque liquids using a 32 factorial experimental design. Based on the F test, p-value, confidence intervals, and percentage contribution of the sum of squares approaches concerning the regression analysis, one concluded that the warm-up time was not a relevant factor in the kinematic viscosity, specifically of very low sulphur fuel oil, Brazilian fuel oil, and atmospheric residue diluted with diesel oil, which are fluids at room temperature.
- Open Access
A Comparative Study of Fuel Density Precision Data Using Digital Densimeter Meters at Two Different Temperatures
The widespread use of liquid fuels can be monitored by their density and light fractions, which affect storage, combustion, handling, and contractual issues. The quantitative measurement of fuel density is carried out using an analytical procedure whose test method presents precision data (repeatability and reproducibility) at 15 °C, whereas Brazilian commercial legislation uses a base temperature of 20 °C. Therefore, the scope of this study was to evaluate whether there are statistically significant differences between these two temperatures. An interlaboratory study, considering homogeneity and stability checks, was carried out, and the data were treated using a one-way analysis of variance in a single-stage nested design for calculating the density precision data (under repeatability and reproducibility conditions). After using an F test to compare the variances at 15 °C and 20 °C, one concluded that these precision data are not always metrologically comparable.
Open AccessA Comparative Study of Fuel Density Precision Data Using Digital Densimeter Meters at Two Different Temperatures
The widespread use of liquid fuels can be monitored by their density and light fractions, which affect storage, combustion, handling, and contractual issues. The quantitative measurement of fuel density is carried out using an analytical procedure whose test method presents precision data (repeatability and reproducibility) at 15 °C, whereas Brazilian commercial legislation uses a base temperature of 20 °C. Therefore, the scope of this study was to evaluate whether there are statistically significant differences between these two temperatures. An interlaboratory study, considering homogeneity and stability checks, was carried out, and the data were treated using a one-way analysis of variance in a single-stage nested design for calculating the density precision data (under repeatability and reproducibility conditions). After using an F test to compare the variances at 15 °C and 20 °C, one concluded that these precision data are not always metrologically comparable.