ZYZhijun Yao

Zhijun Yao

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Zhijun Yao has a total of 23 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Power flow models for high frequency vibration analysis of plates on elastic foundations

    by Chenxi Xiong, Jian Yang, Zhijun Yao, Vu Ngoc Viet Hoang, Xiang Zhu, Marian Wiercigroch

  • Simultaneous Nondestructive Thickness and Acoustic Parameter Determination of Sandwiched Thermal Interface Material Using Ultrasonic Reflection Coefficient Spectroscopy

    by Zhijun Yao, Huanqing Cao, Qimin Zhu, Xiaoliang Zeng, Zhoucheng Su, Nai Yeen Gavin Lai, Jian Yang, Shifeng Guo

    Thermal interface material (TIM) is crucial for heat dissipation of microchips, and their mechanical performance evolution is a key factor for thermal performance and reliability degradation in long-term service. Conventional mechanical characterization methods for TIM are destructive or conducted on standalone bulk samples, thus inefficient or cannot provide a clear understanding of mechanical performance degradation process. This work presents a non-destructive characterization method for TIM in sandwiched structure of Si-TIM-Cu using a flat ultrasonic transducer based on the ultrasonic reflection coefficient spectroscopy. The bond line thickness and acoustic parameters, including longitudinal wave speed, mass density and attenuation of TIM that are related to mechanical properties, are simultaneously determined by minimizing the difference between theoretically calculated and experimentally measured reflection coefficient spectra using the particle swarm optimization algorithm. The acquired thickness, longitudinal wave speed and mass density of the TIM are in good agreement with the reference values measured on bulk samples, with maximum relative errors less than 7.25% and averaged errors less than 5.42%. This ultrasonic method can be further combined with the scanning acoustic microscopy to reveal the relation between mechanical and morphological degradation for better understanding of failure mechanism during material development of TIM.

  • In Situ Measurement of Elastic Constants and Thickness of Silicon–Underfill–Silicon Sandwiched Electronic Package Using Noncontact Laser Ultrasound Array

    by Huanqing Cao, Zhijun Yao, Qimin Zhu, Ruoyu Zhang, Gaolong Lv, Pengli Zhu, Jian Yang, Xinyu Wu, Shifeng Guo

    Quantifying Young’s modulus and Poisson’s ratio of underfill is critical in clarifying material failure mechanism for better optimizing their performance in reducing thermal stresses on solder joints in flip-chip devices. Conventional mechanical methods are generally developed for pure underfill block, and cannot directly measure thin underfill layers sandwiched in heterogeneous multilayered flip-chip devices during service. Non-destructive ultrasonic methods are more promising but are challenged by complex wave propagation induced by multilayered, anisotropic acoustic properties. This work presents a non-contact laser ultrasound (LU) method for in-situ and simultaneous measurement of elastic constants and thickness of thin underfill layer in silicon-underfill-silicon sandwich structure. Longitudinal and transverse waves in divergent propagation directions are acquired by using a line-scan point laser transmitter and fixed point receiver on opposite surfaces. Young’s modulus, Poisson’s ratio, and thickness of sandwiched underfill layer are inversely determined by iteratively matching experimental LU travel times with theoretical predictions considering interface reflection, refraction and mode conversion effects, with relative errors to ultrasonic measured reference values <3.722%. The in-situ LU method is advantageous in continuously monitoring mechanical property evolution during various cyclic tests, advancing reliability assessment and fabrication optimization of underfill materials in real-life electronic packaging applications.


  • Complex-Shaped Surface Reconstruction and Internal Defect Imaging With Omnidirectional Ultrasound Virtually Synthesized by Rotating Probe

    by Qimin Zhu, Peihan Zhao, Zhijun Yao, Mingyu Wang, Junling Fan, Huanqing Cao, Wei Zhang, Xinyu Wu, Shifeng Guo

    Curved structures are quite common in many industrial fields, and are more defect-prone than the planar parts. Ultrasonic imaging of internal defects typically requires multi-degree-of-freedom robotic arms to perform surface-conformal raster scanning with focused ultrasonic probes, maintaining beam-surface orthogonality using pre-known surface contours. In this paper, a simpler inspection strategy is developed for internal defect imaging using only single-element focused ultrasonic probe. The ultrasonic signals rotationally captured at the same linear scan steps are summed to synthesize a virtual ultrasonic beam with nearly omni-directional directivity pattern, aiming to cover specimen in much wider direction. Inverse boundary scattering transform and nearest neighbor search algorithm are introduced to reconstruct curved surface contour. An adaptative virtual source synthetic aperture focusing technique imaging method is proposed to generate a fully focused image by performing delay-and-sum post-processing of the synthesized ultrasonic signals using reconstructed surface contour without requiring prerequisite for a spatial calibration between virtual source and inspected object surface. The above strategy is verified on a plexiglass block with a 21.21-mm curvature radius wavy surface and twelve 3-mm-diameter Side Drilled Holes (SDHs) in staggered depths and spacings. The average absolute position error of surface reconstruction is lower than 0.14 mm, and all SDHs are distinctly visualized with average absolute errors below 0.18 mm in positions. This work provides a promising alternative to ultrasonic imaging of curved structures because it eliminates the need of prior knowledge of surface contour, and surface conformal scanning configuration, simply using a common single-element focused probe.


  • Open Access

    Deep-subwavelength ultrasonic imaging by MHz column-structured metalens: First evidence of quantitative visualization of subsurface defects

    by Shuxiao Zhang, Shifeng Guo, Yehai Li, Huanqing Cao, Min Su, Zhijun Yao, Wei Feng

    High-resolution ultrasonic imaging, which is highly demanded in nondestructive evaluation, is inherently limited by the detection wavelength. Acoustic metamaterial is an emerging technique to achieve subwavelength-resolution ultrasonic imaging beyond the diffraction limit due to its unprecedented acoustic properties. However, existing reports focus on metalenses for manipulating acoustic waves propagating in fluids like air and water, typically at a low-frequency range below 10 kHz. In this paper, a 0.5 MHz periodic column-structured metalens is designed and fabricated to realize deep-subwavelength ultrasonic imaging for quantitive visualization of subsurface defects in solid structures. The silicon-based metalens is designed based on Fabry–Pérot resonance theory. It consists of silicon columns arranged periodically with a lattice constant of 0.2 mm. The Fabry–Pérot resonance frequency is analyzed theoretically and the wave fields of the metalens at resonance mode are verified numerically. The subwavelength ultrasonic imaging performance of the proposed metalens is numerically proved and experimentally demonstrated. As a result, super-resolution ultrasonic imaging (λ/30, with λ being the wavelength) with a high resolving contrast is realized to identify two separated subsurface defects in a stainless-steel structure experimentally with the designed column-structured metalens. This work demonstrates a valuable deep-subwavelength imaging method that beyond traditional diffraction limits and paves the way for enhanced applications in nondestructive evaluation and biomedical diagnosis.