Kentaro Nishiuchi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Kentaro Nishiuchi has a total of 34 co-authors. Here are the top co-authors by number of shared publications:
- Takamichi Murakami
Department of Radiology, Kobe University Graduate School of Medicine
4 shared publications - Keitaro Sofue
Department of Radiology Kobe University Graduate School of Medicine Kobe Japan
3 shared publications - Akihiko Umeno
Department of Radiology, Kobe University Graduate School of Medicine
2 shared publications - Eisuke Ueshima
Department of Radiology, Kobe University Graduate School of Medicine
2 shared publications Izumi Imaoka
Department of Radiology, Kobe University Graduate School of Medicine
2 shared publications- Takeru Yamaguchi
Department of Radiology, Kobe University Graduate School of Medicine, 7-5-2, Kusunokicho, Chuo-ku, Kobe, Hyogo, 650-0017, Japan
2 shared publications
Latest Publications
- 23 September 2026
- Published by Wolters Kluwer Health in Journal of Computer Assisted Tomography
Super-Resolution Deep Learning Reconstruction for 3-Dimensional T1-Weighted Gradient-Echo Imaging in Contrast-Enhanced Liver MRI: Comparison With Conventional and Standard Deep Learning Reconstructions
Purpose: To evaluate the image quality of super-resolution deep learning reconstruction (SR-DLR) for 3-dimensional (3D) T1-weighted gradient-echo (GRE) imaging in contrast-enhanced MRI, compared with conventional reconstruction (Conv.) and standard deep learning reconstruction (DLR). Materials and Methods: This retrospective study included 50 patients (mean age: 71.5 y) with 76 hepatic lesions who underwent contrast-enhanced dynamic liver MRI at 3T. Portal venous phase images were reconstructed using Conv., DLR, and SR-DLR. Quantitative analyses measured liver signal-to-noise ratio (SNR), contrast ratio (CR) between liver parenchyma and lesions, edge rise distance (ERD), and edge rise slope (ERS). Qualitative assessments of image noise, sharpness, contrast, motion artifacts, overall image quality, and lesion conspicuity were performed independently by 2 radiologists using a 5-point scale. Coronal multiplanar reformatted (MPR) images were also evaluated. Statistical comparisons were performed using the Friedman test with Bonferroni correction. Results: Liver SNR was comparable between SR-DLR and DLR. SR-DLR produced sharper edges (lower ERD, higher ERS) and higher lesion-to-liver CR than Conv. and DLR ( P P <0.001). SR-DLR images exhibited slightly higher image noise and motion-related artifacts than DLR. Conclusion: SR-DLR improved spatial resolution, sharpness, and lesion conspicuity in contrast-enhanced MRI compared with Conv. and DLR, indicating potential to improve the diagnostic performance of dynamic liver MRI.
- 23 September 2026
- Published by Wolters Kluwer Health in Journal of Computer Assisted Tomography
Super-Resolution Deep Learning Reconstruction for 3-Dimensional T1-Weighted Gradient-Echo Imaging in Contrast-Enhanced Liver MRI: Comparison With Conventional and Standard Deep Learning Reconstructions
Purpose: To evaluate the image quality of super-resolution deep learning reconstruction (SR-DLR) for 3-dimensional (3D) T1-weighted gradient-echo (GRE) imaging in contrast-enhanced MRI, compared with conventional reconstruction (Conv.) and standard deep learning reconstruction (DLR). Materials and Methods: This retrospective study included 50 patients (mean age: 71.5 y) with 76 hepatic lesions who underwent contrast-enhanced dynamic liver MRI at 3T. Portal venous phase images were reconstructed using Conv., DLR, and SR-DLR. Quantitative analyses measured liver signal-to-noise ratio (SNR), contrast ratio (CR) between liver parenchyma and lesions, edge rise distance (ERD), and edge rise slope (ERS). Qualitative assessments of image noise, sharpness, contrast, motion artifacts, overall image quality, and lesion conspicuity were performed independently by 2 radiologists using a 5-point scale. Coronal multiplanar reformatted (MPR) images were also evaluated. Statistical comparisons were performed using the Friedman test with Bonferroni correction. Results: Liver SNR was comparable between SR-DLR and DLR. SR-DLR produced sharper edges (lower ERD, higher ERS) and higher lesion-to-liver CR than Conv. and DLR ( P P <0.001). SR-DLR images exhibited slightly higher image noise and motion-related artifacts than DLR. Conclusion: SR-DLR improved spatial resolution, sharpness, and lesion conspicuity in contrast-enhanced MRI compared with Conv. and DLR, indicating potential to improve the diagnostic performance of dynamic liver MRI.
- Open Access
Immunoscore Predicted by Dynamic Contrast-Enhanced Computed Tomography Can Be a Non-Invasive Biomarker for Immunotherapy Susceptibility of Hepatocellular Carcinoma
Background/Objectives: Although immunotherapy is the primary treatment option for intermediate-stage hepatocellular carcinoma (HCC), its efficacy varies. This study aimed to identify non-invasive imaging biomarkers predictive of the immunoscore linked to dynamic contrast-enhanced computed tomography (CECT). Methods: We performed immunohistochemical staining with CD3+ and CD8+ antibodies and counted the positive cells in the invasive margin (IM) and central tumor (CT), converting them to an immunoscore of 0 to 4 points. We assessed the dynamic CECT findings obtained from 96 patients who underwent hepatectomy for HCC and evaluated the relationship between dynamic CECT findings and immunoscores. For validation, we assessed the treatment effects on 81 nodules using the Response Evaluation Criteria in Solid Tumors in another cohort of 41 patients who received combined immunotherapy with atezolizumab and bevacizumab (n = 27) and durvalumab and tremelizumab (n = 14). Results: HCCs with peritumoral enhancement in the arterial phase (p < 0.001) and rim APHE (p = 0.009) were associated with the immunoscore in univariate linear regression analysis and peritumoral enhancement in the arterial phase (p = 0.004) in multivariate linear regression analysis. The time to nodular progression in HCCs with peritumoral enhancement in the arterial phase was significantly longer than that in HCCs without this feature (p < 0.001). Conclusions: We identified HCCs with peritumoral enhancement in the arterial phase as a noninvasive imaging biomarker to predict immune-inflamed HCC with a high immunoscore tendency. These HCCs were most likely to respond to combined immunotherapy.
Open AccessImmunoscore Predicted by Dynamic Contrast-Enhanced Computed Tomography Can Be a Non-Invasive Biomarker for Immunotherapy Susceptibility of Hepatocellular Carcinoma
Background/Objectives: Although immunotherapy is the primary treatment option for intermediate-stage hepatocellular carcinoma (HCC), its efficacy varies. This study aimed to identify non-invasive imaging biomarkers predictive of the immunoscore linked to dynamic contrast-enhanced computed tomography (CECT). Methods: We performed immunohistochemical staining with CD3+ and CD8+ antibodies and counted the positive cells in the invasive margin (IM) and central tumor (CT), converting them to an immunoscore of 0 to 4 points. We assessed the dynamic CECT findings obtained from 96 patients who underwent hepatectomy for HCC and evaluated the relationship between dynamic CECT findings and immunoscores. For validation, we assessed the treatment effects on 81 nodules using the Response Evaluation Criteria in Solid Tumors in another cohort of 41 patients who received combined immunotherapy with atezolizumab and bevacizumab (n = 27) and durvalumab and tremelizumab (n = 14). Results: HCCs with peritumoral enhancement in the arterial phase (p < 0.001) and rim APHE (p = 0.009) were associated with the immunoscore in univariate linear regression analysis and peritumoral enhancement in the arterial phase (p = 0.004) in multivariate linear regression analysis. The time to nodular progression in HCCs with peritumoral enhancement in the arterial phase was significantly longer than that in HCCs without this feature (p < 0.001). Conclusions: We identified HCCs with peritumoral enhancement in the arterial phase as a noninvasive imaging biomarker to predict immune-inflamed HCC with a high immunoscore tendency. These HCCs were most likely to respond to combined immunotherapy.
- Open Access
- 1 August 2024
- Published by Springer Nature in Japanese Journal of Radiology
- Vol. 42 (12) , 1469-1478
Comparison of golden-angle radial sparse parallel (GRASP) and conventional cartesian sampling in 3D dynamic contrast-enhanced mri for bladder cancer: a preliminary study
Purpose: To compare the image quality, inter-reader agreement, and diagnostic capability for muscle-invasive bladder cancer (MIBC) of the reconstructed images in sections orthogonal to the bladder tumor obtained by 3D Dynamic contrast-enhanced (DCE)-MRI using the Golden-angle Radial Sparse Parallel (GRASP) technique with the images directly captured using the Cartesian sampling. Materials and methods: This study involved 68 initial cases of bladder cancer examined with DCE-MRI (GRASP: n = 34, Cartesian: n = 34) at 3 Tesla. Four radiologists conducted qualitative evaluations (overall image quality, absence of motion artifact, absence of streak artifact, and tumor conspicuity) using a five-point Likert scale (5 = Excellent/None) and quantitative signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) measurements. The areas under the receiver-operating characteristic curves (AUCs) for the Vesical Imaging-Reporting and Data System (VI-RADS) DCE score for MIBC assessment were calculated. Inter-reader agreement was also assessed. Results: GRASP notably enhanced overall image quality (pooled score: GRASP 4 vs. Cartesian 3, P < 0.0001), tumor conspicuity (5 vs. 3, P < 0.05), SNR (Median 38.2 vs. 19.0, P < 0.0001), and CNR (7.9 vs. 6.0, P = 0.005), with fewer motion artifacts (5 vs. 3, P < 0.0001) and minor streak artifacts (5 vs. 5, P > 0.05). Although no significant differences were observed, the GRASP group tended to have higher AUCs for MIBC (pooled AUCs: 0.92 vs. 0.88) and showed a trend toward higher inter-reader agreement (pooled kappa-value: 0.70 vs. 0.63) compared to the Cartesian group. Conclusions: Using the GRASP for 3D DCE-MRI, the reconstructed images in sections orthogonal to the bladder tumor achieved higher image quality and improve the clinical work flow, compared to the images directly captured using the Cartesian. GRASP tended to have higher diagnostic ability for MIBC and showed a trend toward higher inter-reader agreement compared to the Cartesian.
- 1 August 2024
- Published by Springer Nature in Japanese Journal of Radiology
- Vol. 42 (12) , 1469-1478
Open AccessComparison of golden-angle radial sparse parallel (GRASP) and conventional cartesian sampling in 3D dynamic contrast-enhanced mri for bladder cancer: a preliminary study
Purpose: To compare the image quality, inter-reader agreement, and diagnostic capability for muscle-invasive bladder cancer (MIBC) of the reconstructed images in sections orthogonal to the bladder tumor obtained by 3D Dynamic contrast-enhanced (DCE)-MRI using the Golden-angle Radial Sparse Parallel (GRASP) technique with the images directly captured using the Cartesian sampling. Materials and methods: This study involved 68 initial cases of bladder cancer examined with DCE-MRI (GRASP: n = 34, Cartesian: n = 34) at 3 Tesla. Four radiologists conducted qualitative evaluations (overall image quality, absence of motion artifact, absence of streak artifact, and tumor conspicuity) using a five-point Likert scale (5 = Excellent/None) and quantitative signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) measurements. The areas under the receiver-operating characteristic curves (AUCs) for the Vesical Imaging-Reporting and Data System (VI-RADS) DCE score for MIBC assessment were calculated. Inter-reader agreement was also assessed. Results: GRASP notably enhanced overall image quality (pooled score: GRASP 4 vs. Cartesian 3, P < 0.0001), tumor conspicuity (5 vs. 3, P < 0.05), SNR (Median 38.2 vs. 19.0, P < 0.0001), and CNR (7.9 vs. 6.0, P = 0.005), with fewer motion artifacts (5 vs. 3, P < 0.0001) and minor streak artifacts (5 vs. 5, P > 0.05). Although no significant differences were observed, the GRASP group tended to have higher AUCs for MIBC (pooled AUCs: 0.92 vs. 0.88) and showed a trend toward higher inter-reader agreement (pooled kappa-value: 0.70 vs. 0.63) compared to the Cartesian group. Conclusions: Using the GRASP for 3D DCE-MRI, the reconstructed images in sections orthogonal to the bladder tumor achieved higher image quality and improve the clinical work flow, compared to the images directly captured using the Cartesian. GRASP tended to have higher diagnostic ability for MIBC and showed a trend toward higher inter-reader agreement compared to the Cartesian.
- Open Access
- 16 December 2023
- Published by Elsevier in Radiology Case Reports
- Vol. 19 (3) , 934-938
Uterine diverticulum mimicking endometriotic cyst of the ovary
- 16 December 2023
- Published by Elsevier in Radiology Case Reports
- Vol. 19 (3) , 934-938
Open AccessUterine diverticulum mimicking endometriotic cyst of the ovary