SZSarah Zeriouh

Sarah Zeriouh

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Sarah Zeriouh has a total of 105 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Temperature-controlled Ablation Versus Conventional Ablation for Pulmonary Vein Isolation in the Treatment of AF: A Systematic Review and Meta-Analysis

    by Benjamin Clay, Balamrit S Sokhal, Sarah Zeriouh, Neil T Srinivasan, Parag R Gajendragadkar, Claire A Martin

    Background: This study compared the efficacy and safety of temperature-controlled and conventional contact-force-sensing radiofrequency ablation catheters for pulmonary vein isolation (PVI) in AF. Methods: Seven studies (1,138 patients) were included. Randomised controlled trials and observational (single-arm and two-arm) studies that reported freedom from AF ≥3 months after PVI with temperature-controlled radiofrequency ablation catheters (Biosense Webster QDOT MICRO operating in QMODE or Medtronic DiamondTemp) were included. Results: Freedom from AF at a mean (± SD) follow-up of 9.0 ± 3.6 months did not differ significantly between temperature-controlled and conventional ablation (OR 1.22; 95% CI [−0.79, 1.64]; p=0.24). Total procedure duration (−13.5 minutes; 95% CI [−17.1, −10.0 minutes]; p<0.001) and total ablation duration (−8.9 min; 95% CI [−10.3, −7.5 min]; p<0.01) were significantly shorter for temperature-controlled ablation. There were no significant differences between temperature-controlled and conventional ablation in either the aggregated rates of procedural complications (OR 0.69; 95% CI [−0.15, 1.54]; p=0.11) or in the rate of any individual complication. Conclusion: Temperature-controlled ablation was found to be at least non-inferior to conventional ablation in all measures of efficacy and safety. Further randomised controlled trials are warranted to evaluate long-term rates of freedom from AF and patient comfort.


  • Open Access

    Pulsed-field ablation of atrial fibrillation with a pentaspline catheter across National Health Service England centres

    by Mark T Mills, Saket Trivedi, Matthew J Lovell, Francis Murgatroyd, Peter Calvert, Vishal Luther, Dhiraj Gupta, Claire Martin, Sarah Zeriouh, Greg Mellor, et al.

    Introduction: Pulsed-field ablation (PFA) is a novel modality for pulmonary vein isolation in patients with atrial fibrillation (AF). We describe the initial uptake and experience of PFA using a pentaspline catheter across selected National Health Service England (NHSE) centres. Methods: Data collected by NHSE Specialised Services Development Programme regarding AF ablation procedures using a single-shot, pentaspline, multielectrode PFA catheter (FARAWAVE, Boston Scientific) between June 2022 and August 2024 were aggregated and analysed to examine procedural metrics, acute efficacy and safety outcomes over 3-month follow-up. Results: 1034 procedures were submitted. The patients were 32.1% female, mean age 63.8±10.7 years, 53.1% paroxysmal AF and 89.7% first-time AF ablation. Procedures were performed by 48 consultant operators at nine NHSE centres, with a mean of 115 procedures per centre (range 25–264). 93.7% of procedures were performed under general anaesthesia. Median skin-to-skin procedure time was 74 min (IQR 55–96 min) and fluoroscopy time 20 min (IQR 15–27 min). Electroanatomical mapping was used in 15.3%. In first-time ablation cases, acute isolation of all pulmonary veins was achieved in 99.5% of patients. Left atrial (LA) posterior wall ablation using the PFA catheter was performed in 11.0% of cases; additional LA radiofrequency ablation was performed in 0.6%. The major and minor acute procedural complication rates were, respectively, 1.3% and 3.1%, with no reports of periprocedural death or atrio-oesophageal fistula. 63.8% of patients were discharged on the day of procedure. Follow-up data were available for 870 procedures (84.1%). In the 3 months following ablation, hospitalisation for arrhythmia occurred in 3.2%, with 0.9% rehospitalised for procedural-related complications. Conclusion: In this real-world, nationwide registry of a pentaspline PFA catheter, efficacy, safety and efficiency outcomes were comparable to those from previous PFA studies in patients with AF.


  • Open Access

    Feasibility and procedural safety of the pentaspline pulsed field ablation catheter for atrial lesions beyond pulmonary vein isolation

    by V Sousonis, F Saitta, S Combes, Q Voglimacci-Stephanopoli, R Mene, M Benadel, S Zeriouh, A Betancur, C Cardin, N Combes, et al.

    Background: The pentaspline multi-electrode pulsed-field ablation (PFA) catheter is widely used for the ablation of atrial fibrillation (AF). Given the favorable safety profile of PFA, lesions beyond pulmonary vein isolation (PVI) are increasingly performed. Purpose: We aimed to assess the feasibility and safety of PFA beyond PVI with the pentaspline PFA catheter. Methods: We retrospectively studied all patients who underwent PFA for atrial arrhythmias in our center between January and October 2023. Procedural characteristics and complications were compared between patients undergoing only PVI (PVI-only group) and those receiving extra-venous applications (extra-PVI group). Results: We analysed 202 PFA cases. Indications for ablation included paroxysmal AF (34.7%), persistent AF (57.4%), long-standing persistent AF (5.9%) and atypical atrial flutter (2%). Redo procedures accounted for 18.8% of the total cases. PFA beyond PVI was performed in 142 (70.3%) patients. Patients in the extra-PVI group had a higher incidence of persistent AF (76.8% vs 11.7%, p<0.001), a higher BMI (29±5 vs 26±5 kg/m2, p=0.001) and a more dilated left atrium (LAVI: 73±24 vs 52±20 ml/m2, p<0.001, Table 1). PFA in this group consisted of PVI (98.6%), posterior wall isolation (PWI) (93%), mitral isthmus (MI) ablation (56.3%), a roof line (2.1%), ablation of dispersion electrograms (10.6%) and cavotricuspid isthmus (CTI) ablation (0.7%). In 22 (15.5%) patients, additional CTI ablation with radiofrequency (RF) was performed, while alcohol ablation of the vein of Marshall and RF ablation in the coronary sinus were required in 9 (6.3%) and 2 (1.4%) patients, respectively, to achieve MI block. Compared to the PVI-only group, PFA beyond PVI required a mean of 43 additional applications, a longer procedural (84±29 vs 65±22 min, p<0.001) and fluoroscopy time (25±10 vs 18±6 min, p<0.001) and had a higher fluoroscopy dose (24±35 vs 16.4±28.5 Gy.cm2, p=0.001). A three-dimensional electroanatomic map was used in 12% of cases. Acute success rates were 99% for PVI and PWI, 89% for MI ablation and 100% for roof lines and CTI ablation. Overall complication rates were similar in both groups (16.2% vs 13.3%, p=0.68, Table 2). One cardiac tamponade was observed in the extra-PVI group (0.7%) compared to 4 in the PVI-only group (6.7%, p=0.03). Among the latter, 2 incidents occurred during PVI in patients with long-standing persistent AF, precluding further extra-venous ablation. A small pericardial effusion (without hemodynamic compromise) and/or pericarditis were seen in 9.2% of patients in the extra-PVI group compared to 6.7% in the PVI-only group (p=0.78). No deaths occurred in either group. Conclusions: Ablation beyond PVI with the pentaspline PFA catheter is feasible with high success rates and no apparent increase in procedural complications. However, it increases procedural duration and fluoroscopy. Notably, the majority of cardiac tamponades in this cohort occurred during PVI.

  • Open Access

    Permanent epicardial pacing : a first line strategy in children

    by S Zeriouh, L Koutbi, J Mancini, B Maille, J Hourdain, F Franceschi, J C Deharo

    Background: Permanent cardiac pacing in paediatric patients remains a challenge. According to the European Paediatric and Congenital Society (AEPC) recommendations, below 20 kg epicardial implantation is preferred, while above 20 kg endocardial implantation is given priority unless specific contraindication. In the literature, a weight at 15 kg is also found to be the minimal weight above which an endovascular implantation is considered. However, endovascular systems have been reported to be associated with a high risk of complications. Recent improvements in epicardial leads technology have significantly improved pacing thresholds (1-3), battery life and reduced the risk of re-intervention for epicardial lead dysfunction (4,5). Purpose: The aim of the study is to evaluate the long-term results and efficacy of epicardial pacing in children and to investigate risk factors for epicardial lead dysfunction. Method: We performed a retrospective, single-centre analysis of consecutive patients aged ˂18 years implanted with an epicardial PM between 2004 and 2020. The data collection included initial pacing parameters, at 1 month, 1 year, 2 years, and at last follow-up, as well as occurrence of early and late complications. Results: A total of 101 patients (93 atrial and 131 ventricular epicardial) were analysed. The mean follow-up time was 6.2 years (range 2 days to 16.9 years). Median age at implantation was 4.2 years (IQ 0.3-8.8 years), median weight was 15.2 kg (IQ 5.2-28.0 kg). Congenital heart disease (CHD) was recorded in 59,4% of patients. Reasons for implantation were postoperative complete atrioventricular block (AVB) (40.6%), congenital AVB (37.6%), sinus dysfunction (7.9%), complete AVB with heart disease without surgery (7.9%), others (4%). Four patients had a system infection resulting in device extraction and reimplantation. The mortality rate was 15.8%, but no deaths was directly related to PM implantation or dysfunction. Detection values, impedances were stable over time, and the and average pacing thresholds remained ˂0,98±0,81 volt in the atrium and ˂ 1.57±0,89 volt in the ventricle. Lead survival was 96,7%, 90,7%, 82,3%, 74,5% at 1, 5, 8 and 10 years. The presence of CHD, weight ˂15kg, dual chamber implantation, implantation for postoperative BAV were not significant risk factors for lead dysfunction. In the group of patients implanted above 15kg the presence of a CHD significantly increased the risk of lead dysfunction (p=0.037) and all-cause reimplantation (p=0.010). In the group implanted above 15kg without any cardiopathy, the survival rate without lead dysfunction at 5 and 10 years was 100% and 90.9% respectively. Conclusion: Epicardial pacing in children with steroid-eluting leads shows good long-term results with stable pacing parameters and good survival from lead dysfunction. For children implanted at a weight above 15 kg and without cardiopathy results with epicardial stimulation were excellent.Epicardial lead survival


  • Open Access

    Same-day discharge strategy in a heart rhythm management clinic - what about patients' reported experience?

    by S Zeriouh, V Sousonis, J P Albenque, S Jacob, R Mene, C Cardin, Q Voglimacci-Stepganopoli, N Combes, S Combes, J C Deharo, et al.

    Background and aims: Same-day discharge (SDD) has been adopted for many interventional cardiology procedures, however data on patients’ experience are scarce. The aim of this study was to investigate patient-reported experience of a SDD strategy following electrophysiology procedures (EP) in a Heart Rhythm Management Department. Methods: Consecutive patients undergoing EP procedures in our centre, who fulfilled pre-defined eligibility criteria for SDD, were asked to complete the study questionnaire, right before hospital discharge. Procedures suitable for SDD ranged from non-invasive (electric cardioversion, tilt test) to invasive ones (EP studies, device replacement, rhythm recorders implantation, ablation of supraventricular tachycardias including atrial fibrillation). The questionnaire aimed to assess patients’ experience before and during the procedure, their satisfaction with the quality of the provided information and their comprehension of the given instructions regarding the post-discharge period and their medication. Results: The study questionnaire was completed by 501 patients. The majority of participants described SDD as a good or a quite good experience (n=440, 87,8%), while 94,6% of them (n=474) would not hesitate to undergo a second SDD procedure, if necessary. A direct interview with a healthcare team member was viewed as the preferred method of obtaining information on the procedure. At discharge, 1 out of 10 patients were still unsure of the instructions given by the healthcare team, including their anticoagulation treatment. Patient reported satisfaction rates did not differ between invasive and non-invasive procedures. However, after an invasive procedure, patients seemed to significantly have a better understanding of post-discharge instructions. Conclusion: Patients reported a high level of satisfaction with SDD EP procedures. However, significant efforts need to be made in order to ensure their understanding of post-discharge instructions.Figure : Patients' reported experience

  • Prospective 1-year results of atrial fibrillation ablation using the pentaspline pulsed field ablation catheter: The initial French experience

    by Corentin Chaumont, Emily McDonnell, Serge Boveda, Arnaud Savoure, Anne Rollin, Stephane Combes, Raphael Al Hamoud, Franck Mandel, Sarah Zeriouh, Helene Eltchaninoff, et al.


  • Open Access

    Pulsed field ablation of spatiotemporal electrogram dispersion following pulmonary vein isolation and left atrial linear lesions for persistent atrial fibrillation: a case report

    by Vasileios Sousonis, Quentin Voglimacci-Stephanopoli, Sarah Zeriouh, Serge Boveda, Jean Paul Albenque

    Background: Ablation of persistent atrial fibrillation (AF) remains challenging, with atrial substrate modification often being performed as an adjunct to pulmonary vein isolation (PVI). Pulsed field ablation (PFA) is a novel ablation modality that carries a favourable safety profile, which could facilitate complex procedures. Case summary: We present the case of a 60-year-old male undergoing catheter ablation for symptomatic persistent AF. The procedure was performed with the Farapulse™ PFA system in a stepwise manner, including PVI and linear lesions for the isolation of the posterior left atrial wall and the ablation of the mitral isthmus. The final step of the procedure included the ablation of areas exhibiting spatiotemporal electrogram dispersion, identified with the help of artificial intelligence–based software (VX1, Volta Medical) in both atria. Sinus rhythm was restored after the abolition of an electrogram dispersion zone in the right atrium. The procedure was carried out without any complications. Discussion: Complex ablation procedures for persistent AF can be successfully performed with PFA. In the context of such extensive ablation strategies, PFA is an attractive energy source, given its non-thermal nature that is known to prevent damage to surrounding tissue and result in less chronic fibrosis. However, caution should be exercised to avoid excessive ablation when using the currently available multispline PFA catheter, as it may inadvertently target adjacent areas of healthy myocardium.


  • Open Access

    Efficacy of Intravenous Nitrates for the Prevention of Coronary Artery Spasm During Pulsed Field Ablation of the Mitral Isthmus

    by Roberto Menè, Serge Boveda, Domenico Giovanni Della Rocca, Vasileios Sousonis, Giampaolo Vetta, Sarah Zeriouh, Ioannis Doundoulakis, Andres Betancur, Mohamed Benadel, Nicolas Combes, et al.


  • Top Cited Papers
    Open Access

    Pulsed electric field, cryoballoon, and radiofrequency for paroxysmal atrial fibrillation ablation: a propensity score-matched comparison

    by Domenico G Della Rocca, Lorenzo Marcon, Michele Magnocavallo, Roberto Menè, Luigi Pannone, Sanghamitra Mohanty, Vasileios Sousonis, Antonio Sorgente, Alexandre Almorad, Antonio Bisignani, et al.

    Pulsed field ablation (PFA) has emerged as a novel, non-thermal energy source to selectively ablate cardiac tissue. We describe a multicentre experience on pulmonary vein isolation (PVI) via the pentaspline Farapulse™ PFA system vs. thermal-based technologies in a propensity score-matched population of paroxysmal atrial fibrillation (PAF) patients. Propensity score matching was adopted to compare PVI-only ablation outcomes via the Farawave™ system (Group PFA), cryoballoon (Group CRYO), or focal radiofrequency (Group RF) (PFA:CRYO:RF ratio = 1:2:2). Among 1572 (mean age: 62.4 ± 11.3 years; 42.5% females) PAF patients undergoing first time PVI with either PFA (n = 174), CRYO (n = 655), or RF (n = 743), propensity score matching yielded 174 PFA, 348 CRYO, and 348 RF patients. First-pass isolation was achieved in 98.8% of pulmonary veins (PVs) with PFA, 81.5% with CRYO, and 73.1% with RF (P < 0.001). Procedural and dwell times were significantly shorter with PFA, whereas the availability of a 3D mapping system led to a significant reduction in X-ray exposure with RF. Overall complication rates were 3.4% (n = 6) with PFA, 8.6% (n = 30) with CRYO, and 5.5% (n = 19) with RF (P = 0.052). The 1-year Kaplan–Meier estimated freedom from any atrial tachyarrhythmia was 79.3% with PFA, 74.7% with CRYO, and 72.4% with RF (log-rank P-value: 0.24). Among 145 repeat ablation procedures, PV reconnection rate was 19.1% after PFA, 27.5% after CRYO, and 34.8% after RF (P = 0.01). Pulsed field ablation contributed to significantly shorter procedural times. Follow-up data showed a similar arrhythmia freedom, although a higher rate of PV reconnection was documented in post-CRYO and post-RF redo procedures.