Sarah Casalinova
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Sarah Casalinova has a total of 122 co-authors. Here are the top co-authors by number of shared publications:
Adam D. DeVore
Duke University Medical Center, Division of Cardiology, Department of Medicine, Durham, North Carolina; Duke Clinical Research Institute, Durham, North Carolina
3 shared publications- Brian Lima
Department of Cardiac Surgery, Vanderbilt University Medical Center, Nashville, Tennessee
3 shared publications - Carmelo A. Milano
Department of Cardiac Surgery, Duke University Hospital, Durham, NC (A.B., S.C., S.K., D.G., A.L., G.E., A.D., J.K., C.M., J.S.).
3 shared publications Chetan B. Patel
Duke University Medical Center, Division of Cardiology, Department of Medicine, Durham, North Carolina
3 shared publications- Anthony W. Castleberry
University of Nebraska, Medical Center, Omaha, NE, United States
2 shared publications Carmelo A. Milano
Duke University Medical Center, Division of Cardiovascular and Thoracic Surgery, Department of Surgery, Durham, North Carolina
2 shared publications
Latest Publications
- 1 October 2026
- Published by Wolters Kluwer Health in Circulation: Heart Failure
- Vol. 19 (10)
Donor Heart Preservation at 10 °C Outperforms 4–8 °C With Improved Early Graft Function in Adult Heart Transplantation: A Vanderbilt and Duke Multicenter Study
BACKGROUND: Static cold storage of cardiac allografts at 4–8 °C or 10 °C has yielded promising heart transplant outcomes compared with ice storage. However, direct comparisons between these 2 preservation temperatures are lacking. This dual-center study is the first to compare adult heart transplant outcomes using allografts preserved at 10 °C versus 4–8 °C static cold storage. METHODS: All single-organ, donation-after-brain-death adult heart transplants performed at 2 high-volume centers between January 2020 and April 2025 were retrospectively analyzed. Multiorgan, adult congenital, and donation-after-circulatory-death cases were excluded. A 3:1 nearest-neighbor propensity score matching was applied using a standardized mean difference P =0.004), greater donor-recipient sex mismatch, and more frequent donor undersizing by predicted heart mass ratio. Recipients in this cohort were older and had more re-sternotomies and higher serum creatinine levels at transplant. Patients in the 4–8 °C group were more often listed as Status 2. After matching, 10 °C preservation was associated with less primary graft dysfunction (2 [2.9%] versus 19 [14.6%]; P =0.008), less left and right ventricular dysfunction, reduced new intraaortic balloon pump use, and improved 1-year survival (95.7% versus 86.2%; P =0.02). Other outcomes, including cardiac indices and posttransplant length of stay, were not significantly different between groups. CONCLUSIONS: Preservation of cardiac allografts at 10 °C may yield superior early graft function compared with 4–8 °C static cold storage. However, further prospective studies are required to delineate the optimal donor heart preservation temperature.
- 1 October 2026
- Published by Wolters Kluwer Health in Circulation: Heart Failure
- Vol. 19 (10)
Donor Heart Preservation at 10 °C Outperforms 4–8 °C With Improved Early Graft Function in Adult Heart Transplantation: A Vanderbilt and Duke Multicenter Study
BACKGROUND: Static cold storage of cardiac allografts at 4–8 °C or 10 °C has yielded promising heart transplant outcomes compared with ice storage. However, direct comparisons between these 2 preservation temperatures are lacking. This dual-center study is the first to compare adult heart transplant outcomes using allografts preserved at 10 °C versus 4–8 °C static cold storage. METHODS: All single-organ, donation-after-brain-death adult heart transplants performed at 2 high-volume centers between January 2020 and April 2025 were retrospectively analyzed. Multiorgan, adult congenital, and donation-after-circulatory-death cases were excluded. A 3:1 nearest-neighbor propensity score matching was applied using a standardized mean difference P =0.004), greater donor-recipient sex mismatch, and more frequent donor undersizing by predicted heart mass ratio. Recipients in this cohort were older and had more re-sternotomies and higher serum creatinine levels at transplant. Patients in the 4–8 °C group were more often listed as Status 2. After matching, 10 °C preservation was associated with less primary graft dysfunction (2 [2.9%] versus 19 [14.6%]; P =0.008), less left and right ventricular dysfunction, reduced new intraaortic balloon pump use, and improved 1-year survival (95.7% versus 86.2%; P =0.02). Other outcomes, including cardiac indices and posttransplant length of stay, were not significantly different between groups. CONCLUSIONS: Preservation of cardiac allografts at 10 °C may yield superior early graft function compared with 4–8 °C static cold storage. However, further prospective studies are required to delineate the optimal donor heart preservation temperature.
- Open Access
- 16 April 2026
- Published by Elsevier in The Journal of Heart and Lung Transplantation
- Vol. 45 (9) , 1396-1406
A comparison of DCD heart transplantation in Europe and the United States: A multi-center, retrospective study
- 16 April 2026
- Published by Elsevier in The Journal of Heart and Lung Transplantation
- Vol. 45 (9) , 1396-1406
Open AccessA comparison of DCD heart transplantation in Europe and the United States: A multi-center, retrospective study
- Open Access
- 11 September 2025
- Published by Elsevier in American Journal of Transplantation
- Vol. 26 (1) , 13-19
Increasing the acceptance of thoracoabdominal normothermic regional perfusion in donation after circulatory determination of death heart donation: A case for collaborative donor research
- 11 September 2025
- Published by Elsevier in American Journal of Transplantation
- Vol. 26 (1) , 13-19
Open AccessIncreasing the acceptance of thoracoabdominal normothermic regional perfusion in donation after circulatory determination of death heart donation: A case for collaborative donor research
- 1 May 2024
- Published by Wolters Kluwer Health in Circulation: Heart Failure
- Vol. 17 (5) , e010904
Early Outcomes in Patients With LVAD Undergoing Heart Transplant via Use of the SherpaPak Cardiac Transport System
BACKGROUND: Heart transplant (HT) in recipients with left ventricular assist devices (LVADs) is associated with poor early post-HT outcomes, including primary graft dysfunction (PGD). As complicated heart explants in recipients with LVADs may produce longer ischemic times, innovations in donor heart preservation may yield improved post-HT outcomes. The SherpaPak Cardiac Transport System is an organ preservation technology that maintains donor heart temperatures between 4 °C and 8 °C, which may minimize ischemic and cold-induced graft injuries. This analysis sought to identify whether the use of SherpaPak versus traditional cold storage was associated with differential outcomes among patients with durable LVAD undergoing HT. METHODS: Global Utilization and Registry Database for Improved Heart Preservation-Heart (NCT04141605) is a multicenter registry assessing post-HT outcomes comparing 2 methods of donor heart preservation: SherpaPak versus traditional cold storage. A retrospective review of all patients with durable LVAD who underwent HT was performed. Outcomes assessed included rates of PGD, post-HT mechanical circulatory support use, and 30-day and 1-year survival. RESULTS: SherpaPak (n=149) and traditional cold storage (n=178) patients had similar baseline characteristics. SherpaPak use was associated with reduced PGD (adjusted odds ratio, 0.56 [95% CI, 0.32–0.99]; P =0.045) and severe PGD (adjusted odds ratio, 0.31 [95% CI, 0.13–0.75]; P =0.009), despite an increased total ischemic time in the SherpaPak group. Propensity matched analysis also noted a trend toward reduced intensive care unit (SherpaPak 7.5±6.4 days versus traditional cold storage 11.3±18.8 days; P =0.09) and hospital (SherpaPak 20.5±11.9 days versus traditional cold storage 28.7±37.0 days; P =0.06) lengths of stay. The 30-day and 1-year survival was similar between groups. CONCLUSIONS: SherpaPak use was associated with improved early post-HT outcomes among patients with LVAD undergoing HT. This innovation in preservation technology may be an option for HT candidates at increased risk for PGD. REGISTRATION: URL: https://www.clinicaltrials.gov ; Unique identifier: NCT04141605.
- 1 May 2024
- Published by Wolters Kluwer Health in Circulation: Heart Failure
- Vol. 17 (5) , e010904
Early Outcomes in Patients With LVAD Undergoing Heart Transplant via Use of the SherpaPak Cardiac Transport System
BACKGROUND: Heart transplant (HT) in recipients with left ventricular assist devices (LVADs) is associated with poor early post-HT outcomes, including primary graft dysfunction (PGD). As complicated heart explants in recipients with LVADs may produce longer ischemic times, innovations in donor heart preservation may yield improved post-HT outcomes. The SherpaPak Cardiac Transport System is an organ preservation technology that maintains donor heart temperatures between 4 °C and 8 °C, which may minimize ischemic and cold-induced graft injuries. This analysis sought to identify whether the use of SherpaPak versus traditional cold storage was associated with differential outcomes among patients with durable LVAD undergoing HT. METHODS: Global Utilization and Registry Database for Improved Heart Preservation-Heart (NCT04141605) is a multicenter registry assessing post-HT outcomes comparing 2 methods of donor heart preservation: SherpaPak versus traditional cold storage. A retrospective review of all patients with durable LVAD who underwent HT was performed. Outcomes assessed included rates of PGD, post-HT mechanical circulatory support use, and 30-day and 1-year survival. RESULTS: SherpaPak (n=149) and traditional cold storage (n=178) patients had similar baseline characteristics. SherpaPak use was associated with reduced PGD (adjusted odds ratio, 0.56 [95% CI, 0.32–0.99]; P =0.045) and severe PGD (adjusted odds ratio, 0.31 [95% CI, 0.13–0.75]; P =0.009), despite an increased total ischemic time in the SherpaPak group. Propensity matched analysis also noted a trend toward reduced intensive care unit (SherpaPak 7.5±6.4 days versus traditional cold storage 11.3±18.8 days; P =0.09) and hospital (SherpaPak 20.5±11.9 days versus traditional cold storage 28.7±37.0 days; P =0.06) lengths of stay. The 30-day and 1-year survival was similar between groups. CONCLUSIONS: SherpaPak use was associated with improved early post-HT outcomes among patients with LVAD undergoing HT. This innovation in preservation technology may be an option for HT candidates at increased risk for PGD. REGISTRATION: URL: https://www.clinicaltrials.gov ; Unique identifier: NCT04141605.