Stefano Brattoli
Research Subjects
Stefano Brattoli has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Anna Tolomeo
Radiopharma Division, ITEL Telecomunicazioni s.r.l., 70037 Ruvo di Puglia, BA, Italy
2 shared publications - Giuseppe Capasso
Radiopharmaceutical Division, Itel Telecomunicazioni srl
2 shared publications - Giuseppe Tesse
Radiopharma Division, ITEL Telecomunicazioni s.r.l., 70037 Ruvo di Puglia, BA, Italy
2 shared publications - Marco Spartà
Bioduct s.r.l., Via Di Collodi, 6/C, 50141 Firenze, Italy
2 shared publications - Vincenzo Dimiccoli
ITEL Telecomunicazioni S.r.l., Ruvo di Puglia 70037, Bari, Italy
2 shared publications - Anna Giannelli
Farmacia Ospedaliera, Ospedale Monsignor Raffaele Dimiccoli, 70051 Barletta, BT, Italy
1 shared publication
Latest Publications
- Open Access
- 22 January 2025
- Published by MDPI AG in Pharmaceuticals
- Vol. 18 (2) , 140
Use of Ozone for Disinfection of PHARMODUCT® Automatic System for Antineoplastic Compounding
Background: The purpose of this work was to demonstrate the ozone efficacy for disinfection of the PHARMODUCT® automatic dispensing system for antineoplastic preparation, as a guarantee of a higher grade of cleanliness. While the use of ozone gas disinfection is almost consolidated in food and water treatment, there is a lack of scientific data in the pharmaceutical field. The scope of this study was to demonstrate the ozone efficacy for disinfection of the PHARMODUCT® automatic dispensing system, before starting the antineoplastic preparation, in order to ensure a high degree of cleanliness and, at the same time, to define a biodecontamination procedure that could also be translatable to other automated compounding systems on the market. Methods: Ozone efficacy was determined by calculating the difference (pre-exposure–post-exposure) in CFU counts on the plate. A group of four different ATCC-selected microbial strains were tested using two distinct cycles. The first one was evaluated with an ozone gas concentration of 40 ppm for 40 min; the second cycle increased the concentration to 60 ppm for the same duration. Results: Results showed that exposure to 40 ppm ozone gas led to a 4-log reduction of all tested ATCC strains. In contrast, exposure to 60 ppm ensured a 6-log reduction. Conclusions: The ozone disinfection process, applied to the PHARMODUCT® system, provides a superior grade of cleanliness compared to the manual disinfection procedure, thus offering insight beyond the current anti-inflammatory and analgesic application of ozone therapy in the medical field.
- 22 January 2025
- Published by MDPI AG in Pharmaceuticals
- Vol. 18 (2) , 140
Open AccessUse of Ozone for Disinfection of PHARMODUCT® Automatic System for Antineoplastic Compounding
Background: The purpose of this work was to demonstrate the ozone efficacy for disinfection of the PHARMODUCT® automatic dispensing system for antineoplastic preparation, as a guarantee of a higher grade of cleanliness. While the use of ozone gas disinfection is almost consolidated in food and water treatment, there is a lack of scientific data in the pharmaceutical field. The scope of this study was to demonstrate the ozone efficacy for disinfection of the PHARMODUCT® automatic dispensing system, before starting the antineoplastic preparation, in order to ensure a high degree of cleanliness and, at the same time, to define a biodecontamination procedure that could also be translatable to other automated compounding systems on the market. Methods: Ozone efficacy was determined by calculating the difference (pre-exposure–post-exposure) in CFU counts on the plate. A group of four different ATCC-selected microbial strains were tested using two distinct cycles. The first one was evaluated with an ozone gas concentration of 40 ppm for 40 min; the second cycle increased the concentration to 60 ppm for the same duration. Results: Results showed that exposure to 40 ppm ozone gas led to a 4-log reduction of all tested ATCC strains. In contrast, exposure to 60 ppm ensured a 6-log reduction. Conclusions: The ozone disinfection process, applied to the PHARMODUCT® system, provides a superior grade of cleanliness compared to the manual disinfection procedure, thus offering insight beyond the current anti-inflammatory and analgesic application of ozone therapy in the medical field.
- Open Access
- 21 December 2023
- Published by MDPI AG in Applied Sciences
- Vol. 14 (1) , 106
Performance Qualification of Automatic System for Antineoplastic Preparation
The preparation of antiblastic and parental drugs should be carried out by ensuring an aseptic condition and minimizing exposure to toxic drugs. The aim of this study is to evaluate the quality and qualification of these features of an automated dispensing system, called PHARMODUCT®, built by Bioduct s.r.l, part of the Dedalus group. Three antiblastic drugs (cyclophosphamide (powder), 5-fluorouracil and paclitaxel) were used and three preparation and dispensing sessions were carried out for each drug, using PHARMODUCT®. Some of the infusion bags, prepared for each type of antiblastic, were sent to an external laboratory to perform the quantitative dosage analysis and compare it with the quantitative concentration, set on the automatic dispensing equipment, which was found to meet the acceptance criteria of 10%. In addition, to assess the safety of the process for operator exposure to toxic drugs, the differential pressure value between the main chamber and the clean room was measured to be ˂0 Pa, with an hourly leakage rate of ˂2.5 × 10−3 h−1. Media fill tests showed no microbiological growth after a 14-day incubation period. The PHARMODUCT® system meets the requirements of safety and repeatability for the dispensation of parenteral antiblastic drugs.
- 21 December 2023
- Published by MDPI AG in Applied Sciences
- Vol. 14 (1) , 106
Open AccessPerformance Qualification of Automatic System for Antineoplastic Preparation
The preparation of antiblastic and parental drugs should be carried out by ensuring an aseptic condition and minimizing exposure to toxic drugs. The aim of this study is to evaluate the quality and qualification of these features of an automated dispensing system, called PHARMODUCT®, built by Bioduct s.r.l, part of the Dedalus group. Three antiblastic drugs (cyclophosphamide (powder), 5-fluorouracil and paclitaxel) were used and three preparation and dispensing sessions were carried out for each drug, using PHARMODUCT®. Some of the infusion bags, prepared for each type of antiblastic, were sent to an external laboratory to perform the quantitative dosage analysis and compare it with the quantitative concentration, set on the automatic dispensing equipment, which was found to meet the acceptance criteria of 10%. In addition, to assess the safety of the process for operator exposure to toxic drugs, the differential pressure value between the main chamber and the clean room was measured to be ˂0 Pa, with an hourly leakage rate of ˂2.5 × 10−3 h−1. Media fill tests showed no microbiological growth after a 14-day incubation period. The PHARMODUCT® system meets the requirements of safety and repeatability for the dispensation of parenteral antiblastic drugs.