Andrea Para
Andrea Para has a total of 26 co-authors. Here are the top co-authors by number of shared publications:
- Julien Poublanc
Joint Department of Medical Imaging and the Functional Neuroimaging Lab University Health Network Toronto Ontario Canada
3 shared publications - David John Mikulis
Joint Department of Medical Imaging and the Functional Neuroimaging Lab, University Health Network, Toronto, Ontario, Canada (J.P., D.J.M., O.S.).
2 shared publications - Ece Su Sayin
Department of Physiology, University of Toronto
2 shared publications - James Duffin
Department of Physiology University of Toronto Toronto Ontario Canada
2 shared publications - Joseph Arnold Fisher
University of Toronto
2 shared publications - Olivia Sobczyk
Department of Anaesthesia and Pain Management, University Health Network, University of Toronto, Toronto, ON, Canada
2 shared publications
Latest Publications
- 19 November 2025
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 47 (5) , 1367-1372
Persistent Steal Physiology during a Ramp Cerebrovascular Reactivity Assessment Correlates with Severe Cortical Thinning in Steno-Occlusive Disease
BACKGROUND AND PURPOSE: Steal physiology, a marker of severe cerebrovascular impairment, is associated with cortical thinning, a morphological phenomenon seen in patients with chronic supply artery steno-occlusive disease. This link has been previously established only with a sudden “step” hypercapnic stimulus. The significance of steal patterns derived from a gradual “ramp” stimulus, and their association with structural brain injury, is unclear. We investigated how steal patterns derived from both step and ramp stimuli compare and relate to the severity of cortical thinning in patients with steno-occlusive disease. MATERIALS AND METHODS: Thirty-two patients with unilateral cortical steal, characterized by an asymmetric paradoxical reduction in blood flow during vasodilatory stimuli due to impaired vascular reserve in one hemisphere, were retrospectively identified from a prospectively maintained database. Cerebrovascular reactivity (CVR) was mapped using BOLD MRI during sequential step and ramp CO2 stimuli from a sequential gas delivery system. The spatial extent of cortical steal (volume with negative CVR) was quantified and correlated with inter-hemispheric cortical thickness differences for each stimulus type. RESULTS: The spatial extent of cortical steal physiology derived from the ramp stimulus was consistently smaller, averaging 81% of that seen with the step stimulus (p=0.004). Both stimulus approaches demonstrated significant correlations with cortical thinning (step: r=0.56, p<0.001; ramp: r=0.49, p=0.004). Patients exhibiting steal during both stimulus types showed more pronounced cortical thinning compared to those demonstrating steal only during step stimuli, suggesting that persistent steal across both protocols indicates more severe cerebrovascular impairment. CONCLUSIONS: The persistence of steal physiology seen during a gradual ramp stimulus reveals a more serious hemodynamic impairment than steal observed only during a sudden step challenge in patients with steno-occlusive disease. While the step stimulus is highly sensitive, its greater spatial extent of steal includes all hemodynamically vulnerable tissues, even those with slower but potentially effective collateral responses. The ramp stimulus gives these tissues more time for vascular response to evolve fully, thereby isolating persistent steal that represents complete failure of collateral circulation. This failed adaptation is associated with more severe structural brain injury. Therefore, multi-stimulus CVR protocols may offer a more nuanced approach to risk stratification. ABBREVIATIONS: BOLD=blood-oxygen-level-dependent; CVR=cerebrovascular reactivity.
- 19 November 2025
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 47 (5) , 1367-1372
Persistent Steal Physiology during a Ramp Cerebrovascular Reactivity Assessment Correlates with Severe Cortical Thinning in Steno-Occlusive Disease
BACKGROUND AND PURPOSE: Steal physiology, a marker of severe cerebrovascular impairment, is associated with cortical thinning, a morphological phenomenon seen in patients with chronic supply artery steno-occlusive disease. This link has been previously established only with a sudden “step” hypercapnic stimulus. The significance of steal patterns derived from a gradual “ramp” stimulus, and their association with structural brain injury, is unclear. We investigated how steal patterns derived from both step and ramp stimuli compare and relate to the severity of cortical thinning in patients with steno-occlusive disease. MATERIALS AND METHODS: Thirty-two patients with unilateral cortical steal, characterized by an asymmetric paradoxical reduction in blood flow during vasodilatory stimuli due to impaired vascular reserve in one hemisphere, were retrospectively identified from a prospectively maintained database. Cerebrovascular reactivity (CVR) was mapped using BOLD MRI during sequential step and ramp CO2 stimuli from a sequential gas delivery system. The spatial extent of cortical steal (volume with negative CVR) was quantified and correlated with inter-hemispheric cortical thickness differences for each stimulus type. RESULTS: The spatial extent of cortical steal physiology derived from the ramp stimulus was consistently smaller, averaging 81% of that seen with the step stimulus (p=0.004). Both stimulus approaches demonstrated significant correlations with cortical thinning (step: r=0.56, p<0.001; ramp: r=0.49, p=0.004). Patients exhibiting steal during both stimulus types showed more pronounced cortical thinning compared to those demonstrating steal only during step stimuli, suggesting that persistent steal across both protocols indicates more severe cerebrovascular impairment. CONCLUSIONS: The persistence of steal physiology seen during a gradual ramp stimulus reveals a more serious hemodynamic impairment than steal observed only during a sudden step challenge in patients with steno-occlusive disease. While the step stimulus is highly sensitive, its greater spatial extent of steal includes all hemodynamically vulnerable tissues, even those with slower but potentially effective collateral responses. The ramp stimulus gives these tissues more time for vascular response to evolve fully, thereby isolating persistent steal that represents complete failure of collateral circulation. This failed adaptation is associated with more severe structural brain injury. Therefore, multi-stimulus CVR protocols may offer a more nuanced approach to risk stratification. ABBREVIATIONS: BOLD=blood-oxygen-level-dependent; CVR=cerebrovascular reactivity.
- 12 June 2025
- Published by Wiley in Dermatological Reviews
- Vol. 6 (3)
Examining Periocular Aging: A Narrative Review of its Causes and Aesthetic Interventions
Importance: The periocular area is crucial for facial aesthetics and communication, significantly impacting perceptions of youth and vitality. Understanding its aging mechanisms and refining intervention strategies are essential for optimal outcomes. This review integrates clinical insights from multidisciplinary practice to address gaps in personalized decision‐making.Observations: Contemporary literature and clinical experience identify key periocular aging factors, including sequenced fat compartment deflation, bony resorption, and skin quality decline. Novel findings include a structured algorithm for injectable sequencing, emphasizing deep medial cheek volumization before tear trough correction to mitigate complications. Clinical pearls highlight hybrid techniques (e.g., microdroplet botulinum toxin with HA fillers) for dynamic wrinkles. While hyaluronic acid fillers remain central, case examples demonstrate synergistic outcomes when combined with surgical referrals (e.g., ptosis repair). Emerging ultrasound‐guided approaches enhance precision in high‐risk zones.Conclusions and Relevance: Periocular rejuvenation demands a holistic, individualized strategy. The proposed algorithm, supported by complication management protocols and a surgery‐injectables decision framework, optimizes outcomes. Clinicians must balance volume restoration with anatomical stability, leveraging multidisciplinary insights to address both aesthetic and functional decline.
- 12 June 2025
- Published by Wiley in Dermatological Reviews
- Vol. 6 (3)
Examining Periocular Aging: A Narrative Review of its Causes and Aesthetic Interventions
Importance: The periocular area is crucial for facial aesthetics and communication, significantly impacting perceptions of youth and vitality. Understanding its aging mechanisms and refining intervention strategies are essential for optimal outcomes. This review integrates clinical insights from multidisciplinary practice to address gaps in personalized decision‐making.Observations: Contemporary literature and clinical experience identify key periocular aging factors, including sequenced fat compartment deflation, bony resorption, and skin quality decline. Novel findings include a structured algorithm for injectable sequencing, emphasizing deep medial cheek volumization before tear trough correction to mitigate complications. Clinical pearls highlight hybrid techniques (e.g., microdroplet botulinum toxin with HA fillers) for dynamic wrinkles. While hyaluronic acid fillers remain central, case examples demonstrate synergistic outcomes when combined with surgical referrals (e.g., ptosis repair). Emerging ultrasound‐guided approaches enhance precision in high‐risk zones.Conclusions and Relevance: Periocular rejuvenation demands a holistic, individualized strategy. The proposed algorithm, supported by complication management protocols and a surgery‐injectables decision framework, optimizes outcomes. Clinicians must balance volume restoration with anatomical stability, leveraging multidisciplinary insights to address both aesthetic and functional decline.
- Open Access
- 28 December 2023
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 45 (1) , 44-50
The Choroid Plexus as an Alternative Locus for the Identification of the Arterial Input Function for Calculating Cerebral Perfusion Metrics Using MRI
BACKGROUND AND PURPOSE: MR imaging–based cerebral perfusion metrics can be obtained by tracing the passage of a bolus of contrast through the microvasculature of the brain parenchyma. Thus, the temporal signal pattern of the contrast agent is typically measured over a large artery such as the MCA to generate the arterial input function. The largest intracranial arteries in the brain may not always be suitable for selecting the arterial input function due to skull base susceptibility artifacts or reduced size from steno-occlusive disease. Therefore, a suitable alternative arterial input function window would be useful. The choroid plexus is a highly vascular tissue composed essentially of arterialized blood vessels and acellular stroma with low metabolic requirements relative to its blood flow and may be a suitable alternative to identify the arterial input function. MATERIALS AND METHODS: We studied 8 healthy participants and 7 patients with gliomas who were administered a bolus of gadolinium. We selected an arterial input function from both the left and right M1 segments of the MCA and both lateral ventricles of the choroid plexus for each participant. We compared the changes in the T2* signal and the calculated resting perfusion metrics using the arterial input functions selected from the MCA and choroid plexus. RESULTS: We found no systematic difference between resting perfusion metrics in GM and WM when calculated using an arterial input function from the MCA or choroid plexus in the same participant. CONCLUSIONS: The choroid plexus provides an alternative location from which an arterial input function may be sampled when a suitable measure over an MCA is not available.
- 28 December 2023
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 45 (1) , 44-50
Open AccessThe Choroid Plexus as an Alternative Locus for the Identification of the Arterial Input Function for Calculating Cerebral Perfusion Metrics Using MRI
BACKGROUND AND PURPOSE: MR imaging–based cerebral perfusion metrics can be obtained by tracing the passage of a bolus of contrast through the microvasculature of the brain parenchyma. Thus, the temporal signal pattern of the contrast agent is typically measured over a large artery such as the MCA to generate the arterial input function. The largest intracranial arteries in the brain may not always be suitable for selecting the arterial input function due to skull base susceptibility artifacts or reduced size from steno-occlusive disease. Therefore, a suitable alternative arterial input function window would be useful. The choroid plexus is a highly vascular tissue composed essentially of arterialized blood vessels and acellular stroma with low metabolic requirements relative to its blood flow and may be a suitable alternative to identify the arterial input function. MATERIALS AND METHODS: We studied 8 healthy participants and 7 patients with gliomas who were administered a bolus of gadolinium. We selected an arterial input function from both the left and right M1 segments of the MCA and both lateral ventricles of the choroid plexus for each participant. We compared the changes in the T2* signal and the calculated resting perfusion metrics using the arterial input functions selected from the MCA and choroid plexus. RESULTS: We found no systematic difference between resting perfusion metrics in GM and WM when calculated using an arterial input function from the MCA or choroid plexus in the same participant. CONCLUSIONS: The choroid plexus provides an alternative location from which an arterial input function may be sampled when a suitable measure over an MCA is not available.
- Open Access
- 21 December 2023
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 45 (1) , 37-43
Assessing Perfusion in Steno-Occlusive Cerebrovascular Disease Using Transient Hypoxia-Induced Deoxyhemoglobin as a Dynamic Susceptibility Contrast Agent
BACKGROUND AND PURPOSE: Resting brain tissue perfusion in cerebral steno-occlusive vascular disease can be assessed by MR imaging using gadolinium-based susceptibility contrast agents. Recently, transient hypoxia-induced deoxyhemoglobin has been investigated as a noninvasive MR imaging contrast agent. Here we present a comparison of resting perfusion metrics using transient hypoxia-induced deoxyhemoglobin and gadolinium-based contrast agents in patients with known cerebrovascular steno-occlusive disease. MATERIALS AND METHODS: Twelve patients with steno-occlusive disease underwent DSC MR imaging using a standard bolus of gadolinium-based contrast agent compared with transient hypoxia-induced deoxyhemoglobin generated in the lungs using an automated gas blender. A conventional multi-slice 2D gradient echo sequence was used to acquire the perfusion data and analyzed using a standard tracer kinetic model. MTT, relative CBF, and relative CBV maps were generated and compared between contrast agents. RESULTS: The spatial distributions of the perfusion metrics generated with both contrast agents were consistent. Perfusion metrics in GM and WM were not statistically different except for WM MTT. CONCLUSIONS: Cerebral perfusion metrics generated with noninvasive transient hypoxia-induced changes in deoxyhemoglobin are very similar to those generated using a gadolinium-based contrast agent in patients with cerebrovascular steno-occlusive disease.
- 21 December 2023
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 45 (1) , 37-43
Open AccessAssessing Perfusion in Steno-Occlusive Cerebrovascular Disease Using Transient Hypoxia-Induced Deoxyhemoglobin as a Dynamic Susceptibility Contrast Agent
BACKGROUND AND PURPOSE: Resting brain tissue perfusion in cerebral steno-occlusive vascular disease can be assessed by MR imaging using gadolinium-based susceptibility contrast agents. Recently, transient hypoxia-induced deoxyhemoglobin has been investigated as a noninvasive MR imaging contrast agent. Here we present a comparison of resting perfusion metrics using transient hypoxia-induced deoxyhemoglobin and gadolinium-based contrast agents in patients with known cerebrovascular steno-occlusive disease. MATERIALS AND METHODS: Twelve patients with steno-occlusive disease underwent DSC MR imaging using a standard bolus of gadolinium-based contrast agent compared with transient hypoxia-induced deoxyhemoglobin generated in the lungs using an automated gas blender. A conventional multi-slice 2D gradient echo sequence was used to acquire the perfusion data and analyzed using a standard tracer kinetic model. MTT, relative CBF, and relative CBV maps were generated and compared between contrast agents. RESULTS: The spatial distributions of the perfusion metrics generated with both contrast agents were consistent. Perfusion metrics in GM and WM were not statistically different except for WM MTT. CONCLUSIONS: Cerebral perfusion metrics generated with noninvasive transient hypoxia-induced changes in deoxyhemoglobin are very similar to those generated using a gadolinium-based contrast agent in patients with cerebrovascular steno-occlusive disease.