Lin-Thiri Toon
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Lin-Thiri Toon has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
John Paisey
Cardiac Rhythm Management Research Department, University Hospital Southampton, Southampton, UK
2 shared publications- John Paisey
University Hospital Southampton NHS Foundation Trust, Southampton, UK
2 shared publications Paul R Roberts
Cardiac Rhythm Management, University Hospital Southampton NHS Trust, Southampton, UK
2 shared publications- Alain B. Zemkoho
School of Mathematical Sciences, University of Southampton, Southampton, UK
1 shared publication - Anthony Dunn1 shared publication
Arthur Yue
Cardiac Rhythm Management Research Department, University Hospital Southampton, Southampton, UK
1 shared publication
Latest Publications
- Open Access
- 5 September 2026
- Published by JMIR Publications Inc. in JMIR Preprints
Temporal Variability of the P:R Ratio: A Machine Learning Analysis and Its Implications for EV-ICD Oversensing Risk (Preprint)
BACKGROUND The Extravascular Implantable Cardioverter-Defibrillator (EV-ICD) was developed to address the limitations associated with the Subcutaneous ICD (S-ICD), while avoiding the long-term lead-related complications inherent to transvenous ICD systems. However, inappropriate shocks remain a clinically significant limitation, predominantly attributable to p-wave oversensing, as reported in the EV-ICD Pivotal study. Current EV-ICD implantation relies on static intraoperative electrogram amplitude criteria without formal pre-implant dynamic screening. The temporal behaviour of the P:R ratio during prolonged monitoring has not been systematically characterised. OBJECTIVE The aim of this research is to quantify 24-hour P:R ratio variability across distinct patient subgroups using a validated deep learning-based analytical framework capable of continuous ratio assessment. METHODS Raw 24-hour Holter ECG data (500 Hz sampling frequency) were exported in text format and underwent structured preprocessing, including baseline drift correction via discrete wavelet transformation, targeted filtering for electrical and low-frequency noise, and ARS polarity normalisation. Recordings were segmented into 10-second intervals. Each segment was transformed into a 32x32 Phase Space Reconstruction (PSR) matrix using a 12-ms time delay and analysed using a neural network model designed to predict P:R ratios. Model performance was evaluated using 10-fold cross-validation. Subgroup analyses included heart failure, cardiomyopathy, congenital heart disease, and structurally normal cohorts. RESULTS The neural network converged stably, with no evidence of overfitting, achieving training and validation RMSE values 1:4 during 24-hour monitoring, and nearly 60% exceeded >1:3 in at least one sensing vector. Despite frequent transient elevations, 93% of individuals had at least one vector in which the P:R ratio remained consistently 1:4 threshold, median proportions ranged from 0-5.5% across the three vectors, compared with 0-5% at >1:3. Several subgroups had a median of 0%, with no significant differences between groups (all P>0.05). Wide IQRs indicated substantial inter-individual variability, with a minority showing prolonged periods of elevated P:R ratios. CONCLUSIONS Dynamic fluctuations in P:R ratio are common across both structural heart disease and normal populations; however, sustained elevation is uncommon, and at least one stable sensing vector is present in the vast majority of individuals. These findings highlight the limitations of static intraoperative amplitude assessment and support the potential role of AI-driven prolonged monitoring in refining EV-ICD candidate evaluation and programming strategies. Correlation between surface Holter-derived metrics and substernal EV-ICD sensing vectors requires prospective validation.
- 5 September 2026
- Published by JMIR Publications Inc. in JMIR Preprints
Open AccessTemporal Variability of the P:R Ratio: A Machine Learning Analysis and Its Implications for EV-ICD Oversensing Risk (Preprint)
BACKGROUND The Extravascular Implantable Cardioverter-Defibrillator (EV-ICD) was developed to address the limitations associated with the Subcutaneous ICD (S-ICD), while avoiding the long-term lead-related complications inherent to transvenous ICD systems. However, inappropriate shocks remain a clinically significant limitation, predominantly attributable to p-wave oversensing, as reported in the EV-ICD Pivotal study. Current EV-ICD implantation relies on static intraoperative electrogram amplitude criteria without formal pre-implant dynamic screening. The temporal behaviour of the P:R ratio during prolonged monitoring has not been systematically characterised. OBJECTIVE The aim of this research is to quantify 24-hour P:R ratio variability across distinct patient subgroups using a validated deep learning-based analytical framework capable of continuous ratio assessment. METHODS Raw 24-hour Holter ECG data (500 Hz sampling frequency) were exported in text format and underwent structured preprocessing, including baseline drift correction via discrete wavelet transformation, targeted filtering for electrical and low-frequency noise, and ARS polarity normalisation. Recordings were segmented into 10-second intervals. Each segment was transformed into a 32x32 Phase Space Reconstruction (PSR) matrix using a 12-ms time delay and analysed using a neural network model designed to predict P:R ratios. Model performance was evaluated using 10-fold cross-validation. Subgroup analyses included heart failure, cardiomyopathy, congenital heart disease, and structurally normal cohorts. RESULTS The neural network converged stably, with no evidence of overfitting, achieving training and validation RMSE values 1:4 during 24-hour monitoring, and nearly 60% exceeded >1:3 in at least one sensing vector. Despite frequent transient elevations, 93% of individuals had at least one vector in which the P:R ratio remained consistently 1:4 threshold, median proportions ranged from 0-5.5% across the three vectors, compared with 0-5% at >1:3. Several subgroups had a median of 0%, with no significant differences between groups (all P>0.05). Wide IQRs indicated substantial inter-individual variability, with a minority showing prolonged periods of elevated P:R ratios. CONCLUSIONS Dynamic fluctuations in P:R ratio are common across both structural heart disease and normal populations; however, sustained elevation is uncommon, and at least one stable sensing vector is present in the vast majority of individuals. These findings highlight the limitations of static intraoperative amplitude assessment and support the potential role of AI-driven prolonged monitoring in refining EV-ICD candidate evaluation and programming strategies. Correlation between surface Holter-derived metrics and substernal EV-ICD sensing vectors requires prospective validation.
- Open Access
- 30 April 2026
- Published by Radcliffe Medical Media Ltd in Arrhythmia and Electrophysiology Review
- Vol. 15
Next-generation ICDs: Individualised Selection for Improved Cardiac Outcomes
Cardiovascular disease is a major global cause of death, with sudden cardiac death accounting for up to half of cases, largely due to ventricular tachyarrhythmias. In the UK, approximately 60,000 out-of-hospital cardiac arrests occur annually, with survival rates of only 2–12%. Younger individuals are also affected, with one cardiac-related death daily in those under 35 years of age. Despite advances in care, arrhythmia recurrence remains high (40–50% within 5 years). ICDs have become pivotal in preventing sudden cardiac death, with continuous innovations in device design, implantation, and arrhythmia detection since their introduction in 1980. Transvenous single-chamber ICDs remain the standard, while dual-chamber and CRT defibrillator devices serve patients needing atrial pacing or heart failure support. Subcutaneous and extravascular ICD systems protect patients not requiring pacing while avoiding lead-related risks. Device selection must be individualised, considering clinical profile, comorbidities, lifestyle, patient preferences, and operator expertise. Ongoing advances, including leadless pacing and modular anti-tachycardia pacing systems, continue to expand personalised device strategies.
- 30 April 2026
- Published by Radcliffe Medical Media Ltd in Arrhythmia and Electrophysiology Review
- Vol. 15
Open AccessNext-generation ICDs: Individualised Selection for Improved Cardiac Outcomes
Cardiovascular disease is a major global cause of death, with sudden cardiac death accounting for up to half of cases, largely due to ventricular tachyarrhythmias. In the UK, approximately 60,000 out-of-hospital cardiac arrests occur annually, with survival rates of only 2–12%. Younger individuals are also affected, with one cardiac-related death daily in those under 35 years of age. Despite advances in care, arrhythmia recurrence remains high (40–50% within 5 years). ICDs have become pivotal in preventing sudden cardiac death, with continuous innovations in device design, implantation, and arrhythmia detection since their introduction in 1980. Transvenous single-chamber ICDs remain the standard, while dual-chamber and CRT defibrillator devices serve patients needing atrial pacing or heart failure support. Subcutaneous and extravascular ICD systems protect patients not requiring pacing while avoiding lead-related risks. Device selection must be individualised, considering clinical profile, comorbidities, lifestyle, patient preferences, and operator expertise. Ongoing advances, including leadless pacing and modular anti-tachycardia pacing systems, continue to expand personalised device strategies.
- Open Access
- 19 August 2024
- Published by Springer Nature in Journal of Interventional Cardiac Electrophysiology
- Vol. 68 (1) , 117-123
Is day-case surgical procedure safe for MICRA leadless pacemaker implantation?
Background: MICRA implantation is not commonly done as a day-case procedure. Elective leadless pacemakers are implanted routinely in our centre. Objective: To assess whether the day-case MICRA procedure is safe. Methods: We retrospectively collected data from all patients undergoing elective MICRA implantation at our centre between May 2014 and Nov 2022 (n = 81). Two patient groups were stratified: those planned to be discharged on the same day (SD, n = 52) and those planned to be observed overnight after the procedure (ON, n = 29). Patient demographics, size of the sheath used, type of MICRA device, and rate of complications were recorded. In patients with successful implants (n = 80), device function at discharge and first routine follow-up were evaluated. Results: There were 58% males in the SD group and 45% in the ON group. Median age was 49 years in the SD and 67 years in the ON. Among patients who were planned as a day case, 8 patients had to stay in the hospital but for < 48 h: 2 due to minor groin bleeding, 1 due to patient’s request despite fit to discharge, 4 due to the procedure carried out later in the day, and 1 for observation due to procedural complexity. MICRA implantation was successful in 80 patients. The rate of the major complications was 2% in the SD group and 7% in the ON group (p = 0.223), and none of the co-morbidities assessed showed an association with any complications. Device parameters at the follow-up were available in 76 patients. The rate of patients with low and stable PCT at follow-up was also 98% in the SD group and 96% in the ON group. Conclusions: Day case MICRA procedure can be performed safely in an appropriately selected patient population. Graphical
- 19 August 2024
- Published by Springer Nature in Journal of Interventional Cardiac Electrophysiology
- Vol. 68 (1) , 117-123
Open AccessIs day-case surgical procedure safe for MICRA leadless pacemaker implantation?
Background: MICRA implantation is not commonly done as a day-case procedure. Elective leadless pacemakers are implanted routinely in our centre. Objective: To assess whether the day-case MICRA procedure is safe. Methods: We retrospectively collected data from all patients undergoing elective MICRA implantation at our centre between May 2014 and Nov 2022 (n = 81). Two patient groups were stratified: those planned to be discharged on the same day (SD, n = 52) and those planned to be observed overnight after the procedure (ON, n = 29). Patient demographics, size of the sheath used, type of MICRA device, and rate of complications were recorded. In patients with successful implants (n = 80), device function at discharge and first routine follow-up were evaluated. Results: There were 58% males in the SD group and 45% in the ON group. Median age was 49 years in the SD and 67 years in the ON. Among patients who were planned as a day case, 8 patients had to stay in the hospital but for < 48 h: 2 due to minor groin bleeding, 1 due to patient’s request despite fit to discharge, 4 due to the procedure carried out later in the day, and 1 for observation due to procedural complexity. MICRA implantation was successful in 80 patients. The rate of the major complications was 2% in the SD group and 7% in the ON group (p = 0.223), and none of the co-morbidities assessed showed an association with any complications. Device parameters at the follow-up were available in 76 patients. The rate of patients with low and stable PCT at follow-up was also 98% in the SD group and 96% in the ON group. Conclusions: Day case MICRA procedure can be performed safely in an appropriately selected patient population. Graphical
- 2 July 2024
- Published by Taylor & Francis in Expert Review of Cardiovascular Therapy
- Vol. 22 (7) , 285-288
The dual chamber leadless pacemaker: a game changer for bradycardia management?
- 2 July 2024
- Published by Taylor & Francis in Expert Review of Cardiovascular Therapy
- Vol. 22 (7) , 285-288
The dual chamber leadless pacemaker: a game changer for bradycardia management?
- 1 December 2023
- Published by Taylor & Francis in Future Cardiology
- Vol. 19 (15) , 735-746
The Micra Transcatheter Pacing System: past, present and the future
Leadless permanent pacemakers represent an important innovation in cardiac device developments. Although transvenous permanent pacemakers have become indispensable in managing bradyarrhythmia and s... Plain language summary What is Micra? Micra is a type of leadless pacemaker. Leadless pacemakers are a relatively recent breakthrough in medical science. Regular pacemakers have wires that run into... Tweetable abstract Leadless pacemaker: the future of bradyarrhythmia therapy? Promising clinical efficacy and safety parameters. MicraTM AV system providing AV synchronous pacing. Leadless atrial p...
- 1 December 2023
- Published by Taylor & Francis in Future Cardiology
- Vol. 19 (15) , 735-746
The Micra Transcatheter Pacing System: past, present and the future
Leadless permanent pacemakers represent an important innovation in cardiac device developments. Although transvenous permanent pacemakers have become indispensable in managing bradyarrhythmia and s... Plain language summary What is Micra? Micra is a type of leadless pacemaker. Leadless pacemakers are a relatively recent breakthrough in medical science. Regular pacemakers have wires that run into... Tweetable abstract Leadless pacemaker: the future of bradyarrhythmia therapy? Promising clinical efficacy and safety parameters. MicraTM AV system providing AV synchronous pacing. Leadless atrial p...