ZYZhilu Ye

Zhilu Ye

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Zhilu Ye has a total of 26 co-authors. Here are the top co-authors by number of shared publications:

  • Xiaohui Zhang

    Xi’an Jiaotong University

    3 shared publications
  • Cuiling Zhang

    State Key Laboratory For Manufacturing Systems Engineering Center for Mitochondrial Biology and Medicine School of Life Science and Technology International Joint Laboratory for Micro/Nano Manufacturing and Measurement Technology Key Laboratory of Biomedical Information Engineering of Ministry of Education Xi'an Key Laboratory For Biomedical Testing and High‐end Equipment Xi'an Jiaotong University Xi'an Shaanxi China

    2 shared publications
  • Yijing Wang

    State Key Laboratory For Manufacturing Systems Engineering Center for Mitochondrial Biology and Medicine School of Life Science and Technology International Joint Laboratory for Micro/Nano Manufacturing and Measurement Technology Key Laboratory of Biomedical Information Engineering of Ministry of Education Xi'an Key Laboratory For Biomedical Testing and High‐end Equipment Xi'an Jiaotong University Xi'an Shaanxi China

    2 shared publications
  • Bin Peng

    State Key Laboratory for Manufacturing Systems Engineering, Electronic Materials Research Laboratory, Key Laboratory of the Ministry of Education, School of Electronic Science and Engineering, Xi'an Jiaotong University , Xi'an 710049

    1 shared publication
  • Jingen Wu

    State Key Laboratory for Manufacturing Systems Engineering Electronic Materials Research Laboratory Engineering Research Center of Spin Quantum Sensor Chips Key Laboratory of the Ministry of Education Universities of Shaanxi Province School of Electronic Science and Engineering Xi'an Jiaotong University Xi'an China

    1 shared publication
  • Jingyu Tian

    State Key Laboratory For Manufacturing Systems Engineering Center for Mitochondrial Biology and Medicine School of Life Science and Technology International Joint Laboratory for Micro/Nano Manufacturing and Measurement Technology Key Laboratory of Biomedical Information Engineering of Ministry of Education Xi'an Key Laboratory For Biomedical Testing and High‐end Equipment Xi'an Jiaotong University Xi'an Shaanxi China

    1 shared publication

Latest Publications

  • Open Access

    A Millimeter‐Scale Implantable Magneto–Mechano–Electric Transducer Based on BTO Piezoelectric Ceramics for Remote Wireless Electrical Stimulation of Injured Sciatic Nerves

    by Yijing Wang, Jingyu Tian, Zhe Xu, Cuiling Zhang, Jingen Wu, Ming Liu, Zhilu Ye, Xiaohui Zhang

    Electrical stimulation is widely recognized as an effective strategy for promoting functional recovery after peripheral nerve injury. However, conventional stimulators rely on wired connections or implanted batteries, severely limiting implantability, biosafety, and clinical translation. Recent wireless, battery‐free piezoelectric systems, primarily based on ultrasound or pressure‐driven transduction, remain constrained by auxiliary equipment, working distance, and external control. Here, we report a fully wireless, circuit‐free neural stimulator built on a millimetric magneto‐mechano‐electric (MME) cantilever transducer (3 × 10 × 5 mm) with a barium titanate (BTO) piezoelectric ceramic core. Under low‐frequency alternating magnetic fields, the MME cantilever mechanically oscillates, inducing stress on the BTO element and thereby converting magnetic energy into therapeutic electrical pulses. The use of BTO minimizes potential biosafety risks. Moreover, the device operates stably at 16 cm from the magnetic source, outperforming most existing wireless stimulators. In vitro, MME‐mediated stimulation doubles PC12 neurite outgrowth and neuronal differentiation. In a rat sciatic nerve injury model, the implanted stimulator exhibits excellent biosafety and significantly enhances nerve regeneration and motor recovery, achieving a ∼1.5‐fold improvement in the sciatic functional index.


  • Open Access

    Advances in wearable and implantable devices for wireless electrical stimulation therapy

    by Yue Zhang, Yijing Wang, Kun Zhao, Minye Yang, Zhilu Ye, Xiaohui Zhang


  • A flexible silk film based on synergy of hydrogen bonds and a cross-linking network for magnetic sensitive skin

    by Cuiling Zhang, Qi Zhang, Xinran Li, Wang Zhan, Yongliang Han, Zeying Zhang, Wei Su, Li Xue, Wei Zhang, Ke Zhou, et al.

    Magnetoresistive (MR) sensors with the ability to detect external magnetic fields have attracted increasing attention in interactive human–machine interfaces and biomedical devices. However, existing MR sensors are typically constructed from rigid and bulky materials, failing to satisfy the flexibility and biocompatibility requirements for on-skin electronics. In this study, a flexible and biocompatible anisotropic magnetoresistance (AMR) film with a cross-linked silk substrate and a NiCo functional layer is reported for on-skin monitoring applications. The synergy of hydrogen bonds and the cross-linking network enhances the flexibility and mechanical stability of the silk film by forming an amorphous entanglement network with a reduced presence of large and compact β-sheet crystals. The developed AMR film exhibits a high AMR ratio of 1.03%, comparable to those obtained with rigid AMR sensors. Under external magnetic fields, the silk-based AMR film demonstrates the ability to monitor its rotation (0–90°), bending (radius 10–60 mm), and distance (0–10 cm) to the magnet. Furthermore, we practically implement the flexible AMR film for skin-interfaced applications, including the detection of joint motions (e.g. wrist, ankle, and finger movements) and the control of turning pages. The proposed flexible magnetic film paves the way for the development of magnetosensitive electronic skins and wearable sensors.


  • Open Access

    Materials, Designs, and Implementations of Wearable Antennas and Circuits for Biomedical Applications: A Review

    by Minye Yang, Zhilu Ye, Yichong Ren, Mohamed Farhat, Pai-Yen Chen

    The intersection of biomedicine and radio frequency (RF) engineering has fundamentally transformed self-health monitoring by leveraging soft and wearable electronic devices. This paradigm shift presents a critical challenge, requiring these devices and systems to possess exceptional flexibility, biocompatibility, and functionality. To meet these requirements, traditional electronic systems, such as sensors and antennas made from rigid and bulky materials, must be adapted through material science and schematic design. Notably, in recent years, extensive research efforts have focused on this field, and this review article will concentrate on recent advancements. We will explore the traditional/emerging materials for highly flexible and electrically efficient wearable electronics, followed by systematic designs for improved functionality and performance. Additionally, we will briefly overview several remarkable applications of wearable electronics in biomedical sensing. Finally, we provide an outlook on potential future directions in this developing area.