Takayuki Yoneyama
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Takayuki Yoneyama has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- Haruto Hiraba
Department of Dental Materials, Nihon University School of Dentistry, Tokyo, Japan
6 shared publications - Hiroyasu Koizumi
Department of Dental Materials, Nihon University School of Dentistry
4 shared publications - Kosuke Takehana
Department of Dental Materials, Nihon University School of Dentistry
4 shared publications - Akihisa Kodaira
Department of Fixed Prosthodontics, Nihon University School of Dentistry, 1-8-13, Kanda-Surugadai, Chiyoda-Ku, Tokyo 101-8310, Japan
1 shared publication - Equo Kobayashi
Department of Materials Science and Engineering, Tokyo Institute of Technology, Tokyo, Japan
1 shared publication Hideo Matsumura
Department of Fixed Prosthodontics, Nihon University School of Dentistry, 1-8-13 Kanda-Surugadai, Chiyoda-ku, Tokyo 101-8310, Japan
1 shared publication
Latest Publications
- Open Access
- 1 January 2026
- Published by Nihon University School of Dentistry in Journal of Oral Science
- Vol. 68 (3) , 26-0108-183
Enhanced corrosion resistance of Ti-6Al-7Nb and Ti-6Al-4V alloys through electrochemical surface treatment for biomedical applications
Electrochemical surface treatment (ET) was applied to Ti-6Al-7Nb and Ti-6Al-4V alloys to enhance their corrosion resistance for biomedical applications. Disk-shaped specimens were treated in a water-glycerin-lactic acid electrolyte under a constant voltage of 50 V. Corrosion behavior was evaluated by anodic polarization in 0.9% saline, and the surface chemistry was analyzed using X-ray photoelectron spectroscopy (XPS). ET shifted the corrosion potential toward more noble values and reduced the passive current density for both alloys. XPS revealed a marked increase in the Ti4+ fraction, indicating the formation of a TiO2-enriched surface layer. Overall, ET enhanced the passivation of high-strength titanium alloys used in medical and dental prostheses.
- 1 January 2026
- Published by Nihon University School of Dentistry in Journal of Oral Science
- Vol. 68 (3) , 26-0108-183
Open AccessEnhanced corrosion resistance of Ti-6Al-7Nb and Ti-6Al-4V alloys through electrochemical surface treatment for biomedical applications
Electrochemical surface treatment (ET) was applied to Ti-6Al-7Nb and Ti-6Al-4V alloys to enhance their corrosion resistance for biomedical applications. Disk-shaped specimens were treated in a water-glycerin-lactic acid electrolyte under a constant voltage of 50 V. Corrosion behavior was evaluated by anodic polarization in 0.9% saline, and the surface chemistry was analyzed using X-ray photoelectron spectroscopy (XPS). ET shifted the corrosion potential toward more noble values and reduced the passive current density for both alloys. XPS revealed a marked increase in the Ti4+ fraction, indicating the formation of a TiO2-enriched surface layer. Overall, ET enhanced the passivation of high-strength titanium alloys used in medical and dental prostheses.
- 7 July 2025
- Published by Springer Nature in Odontology
- Vol. 114 (2) , 686-691
Effect of casting pressure on the castability of commercially pure titanium using a one-chamber casting machine
The purpose of this study was to investigate the effect of casting pressure on the combination of magnesia-based investment mold and one-chamber casting equipment (Symbion) for the castability of commercially pure titanium (CP Ti) and to compare the castability from this combination system with that of the centrifugal casting equipment (Selecast system). The castability of the mesh type specimen (n = 9) was evaluated in terms of the number of cast segments (castability index). The castability index was calculated as a percentage of the porous area for each mesh specimen versus the total number of complete cast segments. Kruskal–Wallis non-parametric analysis was conducted, and the castability indices of the three groups were compared using Dunn’s multiple comparison test (alpha = 0.05). The Symbion 0.13 MPa group exhibited a significantly lower castability index than the Symbion 0.20 MPa and the Selecast groups. It was concluded that when the one-chamber casting machine is used with the magnesia-based mold material and 0.2 MPa gas pressure, the CP Ti castability index could be similar to that of the Selecast system.
- 7 July 2025
- Published by Springer Nature in Odontology
- Vol. 114 (2) , 686-691
Effect of casting pressure on the castability of commercially pure titanium using a one-chamber casting machine
The purpose of this study was to investigate the effect of casting pressure on the combination of magnesia-based investment mold and one-chamber casting equipment (Symbion) for the castability of commercially pure titanium (CP Ti) and to compare the castability from this combination system with that of the centrifugal casting equipment (Selecast system). The castability of the mesh type specimen (n = 9) was evaluated in terms of the number of cast segments (castability index). The castability index was calculated as a percentage of the porous area for each mesh specimen versus the total number of complete cast segments. Kruskal–Wallis non-parametric analysis was conducted, and the castability indices of the three groups were compared using Dunn’s multiple comparison test (alpha = 0.05). The Symbion 0.13 MPa group exhibited a significantly lower castability index than the Symbion 0.20 MPa and the Selecast groups. It was concluded that when the one-chamber casting machine is used with the magnesia-based mold material and 0.2 MPa gas pressure, the CP Ti castability index could be similar to that of the Selecast system.
- Open Access
- 1 January 2024
- Published by Asian Pacific Journal of Dentistry in Asian Pacific Journal of Dentistry
- Vol. 24 (2) , 24-25
Vat photo-polymerized denture marking plate processed with a three-dimensional printer
A simple processing technique for a denture marking plate is reported. An outline of the rectangular plate was designed with a three-dimensional (3D) software. The alphanumeric size was set at approximately 2-mm in height. The current case printed telephone code number, abbreviation of university, and prefectural code, with 0.75-mm in depth. The alphanumeric groove was filled with white colored opaque resin. The plate was inserted into the denture base with an acrylic repair resin. The numbers and letters were clearly visible through the acrylic resin material. This method is applicable to varying sizes of marking plates placed on partial dentures.
- 1 January 2024
- Published by Asian Pacific Journal of Dentistry in Asian Pacific Journal of Dentistry
- Vol. 24 (2) , 24-25
Open AccessVat photo-polymerized denture marking plate processed with a three-dimensional printer
A simple processing technique for a denture marking plate is reported. An outline of the rectangular plate was designed with a three-dimensional (3D) software. The alphanumeric size was set at approximately 2-mm in height. The current case printed telephone code number, abbreviation of university, and prefectural code, with 0.75-mm in depth. The alphanumeric groove was filled with white colored opaque resin. The plate was inserted into the denture base with an acrylic repair resin. The numbers and letters were clearly visible through the acrylic resin material. This method is applicable to varying sizes of marking plates placed on partial dentures.
- Open Access
- 1 January 2024
- Published by Asian Pacific Journal of Dentistry in Asian Pacific Journal of Dentistry
- Vol. 24 (1) , 5-8
Influence of ultrasonic vibration on bond strength of luting agents joined to particle abraded base metal alloy
Purpose: The aim of the current study is to evaluate the influence of ultrasonic vibration on bond strength of four luting agents joined to particle abraded base metal alloy.Methods: Cast disc specimens made of nickel-chromium (Ni-Cr) were airborne-particle abraded with alumina and bonded with four luting agents. The specimens were stored in water, and subsequently vibrated with an ultrasonic generator for up to 5 min. Shear bond strength was determined with universal testing device.Results: Bond strength in MPa without vibration (baseline, BL) was 51.8 for composite luting agent, 25.1 for glass ionomer cement (GIC), 12.9 for zinc polycarboxylate cement (PCC), and 6.1 MPa for zinc phosphate cement (ZPC). The specimens cemented with ZPC were detached within 1 minute during application of ultrasound, whereas 1-min/BL bond strength ratio was 102 for PCC, 87 for GIC, and 88 for composite luting agent.Conclusion: Ultrasonic vibration effectively reduced bond strength to Ni-Cr alloy of ZPC. Reduction in bond strength was not apparent up to 2-min vibration for PCC, 3-min vibration for GIC, and 1-min vibration for composite luting agent. Care must be taken in the application of ultrasound for removing cast restorations seated with PCC, GIC, and composite resin luting agent.
- 1 January 2024
- Published by Asian Pacific Journal of Dentistry in Asian Pacific Journal of Dentistry
- Vol. 24 (1) , 5-8
Open AccessInfluence of ultrasonic vibration on bond strength of luting agents joined to particle abraded base metal alloy
Purpose: The aim of the current study is to evaluate the influence of ultrasonic vibration on bond strength of four luting agents joined to particle abraded base metal alloy.Methods: Cast disc specimens made of nickel-chromium (Ni-Cr) were airborne-particle abraded with alumina and bonded with four luting agents. The specimens were stored in water, and subsequently vibrated with an ultrasonic generator for up to 5 min. Shear bond strength was determined with universal testing device.Results: Bond strength in MPa without vibration (baseline, BL) was 51.8 for composite luting agent, 25.1 for glass ionomer cement (GIC), 12.9 for zinc polycarboxylate cement (PCC), and 6.1 MPa for zinc phosphate cement (ZPC). The specimens cemented with ZPC were detached within 1 minute during application of ultrasound, whereas 1-min/BL bond strength ratio was 102 for PCC, 87 for GIC, and 88 for composite luting agent.Conclusion: Ultrasonic vibration effectively reduced bond strength to Ni-Cr alloy of ZPC. Reduction in bond strength was not apparent up to 2-min vibration for PCC, 3-min vibration for GIC, and 1-min vibration for composite luting agent. Care must be taken in the application of ultrasound for removing cast restorations seated with PCC, GIC, and composite resin luting agent.
- Open Access
- 21 December 2023
- Published by Elsevier in Japanese Dental Science Review
- Vol. 60, 40-43
Current status of dental journals published by Japanese organization
- 21 December 2023
- Published by Elsevier in Japanese Dental Science Review
- Vol. 60, 40-43
Open AccessCurrent status of dental journals published by Japanese organization
- 1 March 2021
- Published by Elsevier in Dental Materials
- Vol. 37 (3) , e176-e181
Adhesive bonding of noble metals with a thiohydantoin primer
- 1 March 2021
- Published by Elsevier in Dental Materials
- Vol. 37 (3) , e176-e181
Adhesive bonding of noble metals with a thiohydantoin primer
- 1 January 2000
- Published by Walter de Gruyter GmbH in Frontiers of Medical and Biological Engineering
- Vol. 10 (2) , 97-103
Super-elastic property of Ti-Ni alloy for use in dentistry
"Super-elastic property of Ti-Ni alloy for use in dentistry" published on 01 Jan 2000 by VSP.
- 1 January 2000
- Published by Walter de Gruyter GmbH in Frontiers of Medical and Biological Engineering
- Vol. 10 (2) , 97-103
Super-elastic property of Ti-Ni alloy for use in dentistry
"Super-elastic property of Ti-Ni alloy for use in dentistry" published on 01 Jan 2000 by VSP.