  • Open Access

    Safety and Chronic Atrial Lesion Formation With a Large-Tip, Contact-Force-Sensing Multipolar Pulsed Field Ablation Catheter: Effect of Application Number in a Porcine Beating Heart Model

    by Luigi Di Biase, Jacopo Marazzato, Marco Schiavone, Fengwei Zou, Taylor Spangler, Rahul Bhardwaj, Jonathan Hsu, Assaf Govari, Andreas Altman, Kevin Okarski, et al.

    BACKGROUND: Integration of catheter–tissue contact force with pulsed field ablation (PFA) dosing is essential for achieving safe and durable lesion formation with contact force sensing catheters in ventricular models. However, data on the use of these catheters for atrial ablation remain limited. This study evaluated the procedural safety and 30-day lesion characteristics of atrial PFA delivered with the OMNYPULSE ablation catheter in a porcine model. METHODS: Twelve pigs were randomized to receive either 6 (×6 or Group A) or 12 (×12 or group B) PFA applications per ablation. Following 3-dimensional electroanatomic mapping, PFA was delivered to the right superior and inferior pulmonary veins, cavotricuspid isthmus, right atrial posterior wall, left atrial roof, and mitral annulus. Procedural safety was assessed acutely, and lesion characteristics were evaluated on 30-day histology. Maximum transmurality extent (MTE) was defined as >80% of the lesion span exhibiting continuous endocardial-to-epicardial fibrosis within representative histological sections. RESULTS: Adequate catheter–tissue contact was achieved during PFA delivery (contact force, 28±15 g). No acute procedural complications were observed. At 30 days, PVs and right atrial sites (ie, cavotricuspid isthmus and right atrial posterior wall) demonstrated near-complete MTE regardless of PFA dosing. In contrast, MTE was significantly lower at the mitral annulus and LA roof compared with other sites (44±30% and 21±26%, respectively; P <0.001). Increasing the number of PFA applications (×12) resulted in a remarkable improvement in MTE at these locations, with MTE increases of up to 68% compared with ×6 dosing at these sites. CONCLUSIONS: Atrial PFA using the OMNYPULSE catheter was feasible and safe in a porcine model. However, lesion transmurality varied by atrial location and was dose-dependent at select sites, underscoring the need for site-specific PFA dosing strategies. Further studies are warranted to define optimal PFA parameters for consistent atrial lesion formation.


  • Open Access

    Real-Time Prediction of Irreversible Lesion Size During Pulsed Field Ablation: Prospective Validation of a Novel Ablation Index Based on Contact Force and Number of Applications in a Swine Beating Heart Model

    by Hiroshi Nakagawa, Salman Farshchi-Heydari, Masafumi Sugawara, Atsushi Ikeda, Jennifer Maffre, Tushar Sharma, Philip Lam, Assaf Govari, Christopher T. Beeckler, Andres Altmann, et al.

    BACKGROUND: In a previous study, on pulsed-field ablation (PFA) in the swine ventricle, we found that lesion depth was described (±1 mm accuracy) by a logarithmic function of contact force (CF) and the number of PFA pulses (PF-ablation index). This study was designed to validate prospectively whether the novel PF-ablation index would allow PFA lesions to be created at depths of 3.5, 4.5, 5.5, and 6.5 mm with high prediction accuracy in a swine-beating heart model. METHODS: A 7.5F catheter with a 3.5 mm ablation electrode and CF sensor (ThermoCool SmartTouch SF-Dual Energy) was connected to a PFA system (TRUPULSE 2). In 6 closed-chest swine, a biphasic PFA pulse was delivered between the ablation electrode and a skin patch at 123 separate ventricular sites at 5 different levels of CF (1) low (average CF: 4–15 g; median, 12 g; n=25), (2) moderate (16–30 g; median, 23 g; n=41); 3) high (31–45 g; median, 36 g; n=27), (4) very high (46–68 g; median, 52 g; n=18); or (5) no electrode contact, 1 to 2 mm from the endocardium (n=12). PFA application was terminated when the PF-ablation index reached a predicted lesion depth of 3.5 mm (27 sites), 4.5 mm (25 sites), 5.5 mm (29 sites), and 6.5 mm (30 sites). Swine were euthanized 2 hours after ablation. Lesion size was measured using triphenyl tetrazolium chloride staining. RESULTS: Predicted lesion depth by the PF-ablation index correlated well with actual lesion depthwith ±1.0 mm accuracy in 97/106 (92%) lesions and ±1.5 mm accuracy in all 106 lesions. There were no or poor relationships between intracardiac electrogram attenuation, impedance decrease, electrode temperature, and lesion size. No detectable lesions were created without electrode contact. CONCLUSIONS: A novel PF-ablation index incorporating CF and the number of PFA pulses provides high accuracy in predicting lesion depth in real-time. Intracardiac electrogram attenuation, impedance decrease, and electrode temperature are poor predictors of PFA lesion size.


  • Open Access

    Pulsed Field Ablation Index–Guided Ablation for Lesion Formation: Impact of Contact Force and Number of Applications in the Ventricular Model

    by Luigi Di Biase, Jacopo Marazzato, Assaf Govari, Andreas Altman, Christopher Beeckler, Joe Keyes, Tushar Sharma, Vito Grupposo, Fengwei Zou, Masafumi Sugawara, et al.

    BACKGROUND: The effect of contact force (CF) on lesion formation is not clear during pulsed field ablation (PFA). The aim of this study was to evaluate the impact of CF, PFA, and their interplay through the PFA index (PF index) formula on the ventricular lesion size in swine. METHODS: PFA was delivered through the CF-sensing OMNYPULSE catheter. Predefined PFA applications (×3, ×6, ×9, and ×12) were delivered maintaining low (5–25 g), high (26–50 g), and very high (51–80 g) CFs. First, PFA lesions were evaluated on necropsy in 11 swine to investigate the impact of CF/PFA—and their integration in the PF index equation—on lesion size (study characterization). Then, 3 different PF index thresholds—300, 450, and 600—were tested in 6 swine to appraise the PF index accuracy to predict the ventricular lesion depth (study validation). RESULTS: In the study characterization data set, 111 PFA lesions were analyzed. CF was 32±17 g. The average lesion depth and width were 3.5±1.2 and 12.0±3.5 mm, respectively. More than CF and PFA dose alone, it was their combined effect to impact lesion depth through an asymptotically increasing relationship. Likewise, not only was the PF index related to lesion depth in the study validation data set (r 2 =0.66; P <0.001) but it also provided a prediction accuracy of the observed depth of ±2 mm in 69/73 lesions (95%). CONCLUSIONS: CF and PFA applications play a key role in lesion formation during PFA. Further studies are required to evaluate the best PFA ablation settings to achieve transmural lesions.


  • Open Access

    Point-by-Point Pulsed Field Ablation Using a Multimodality Generator and a Contact Force–Sensing Ablation Catheter: Comparison With Radiofrequency Ablation in a Remapped Chronic Swine Heart

    by Luigi Di Biase, Jacopo Marazzato, Fengwei Zou, Aung Lin, Vito Grupposo, Nilarun Chowdhuri, Jennifer Maffre, Salman Farshchi-Heydari, Tushar Sharma, Christopher Beeckler, et al.

    Background: Pulsed field ablation (PFA) has emerged as an alternative to radiofrequency ablation. However, data on focal point-by-point PFA are scarce. The aim of this study was to compare lesion durability and collateral damage between focally delivered unipolar/biphasic PFA versus radiofrequency in swine. Methods: Eighteen swine were randomized to low-dose PFA, high-dose PFA, and radiofrequency using a multimodality generator. Radiofrequency delivered by market-available generator served as control group. A contact force–sensing catheter was used to focally deliver PFA/radiofrequency at the pulmonary veins and other predefined sites in the atria. Animals were remapped postprocedurally and 28 days postablation to test lesion durability followed by gross necroscopy and histology. Results: All targeted sites were successfully ablated (contact force value, 13.9±4.1 g). Follow-up remapping showed persistent pulmonary vein isolation in all animals (100%) with lesion durability at nonpulmonary vein sites proven in most (98%). Regardless of the energy source used, the lesion size was similar across the study groups. Transmurality was achieved in 95% of targeted sites and 100% at pulmonary veins. On histology, PFA animals showed more mature scar formation than their radiofrequency counterpart without myocardial necrosis or inflammation. Finally, no sign of collateral damage was observed in any of the groups. Conclusions: In a randomized preclinical study, focally delivered unipolar/biphasic PFA guided by contact force values was associated with durable lesions on chronic remapping and with mature scar formation on histology without signs of collateral injury on necroscopy. Further studies are needed to investigate the long-term feasibility of this new approach to atrial fibrillation treatment.