ZWZhao Wang

Zhao Wang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Zhao Wang has a total of 20 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Marker points 3D matching based on Delaunay triangfulation structure and error dispersion

    by Ruidi Jin, Zhao Wang, Junhui Huang, Zijun Li, Qiongqiong Duan, Miaowei Qi, Wei Wang, Qiang Dong

    Point cloud registration techniques based on marker points are widely used in optical 3D industrial measurements. However, in this process, marker points 3D matching methods are often haunted by low efficiency and accuracy. To improve the performance of marker points 3D matching, we propose a two-step method of ‘matching-verification’. In the matching process, Delaunay triangulation is introduced to extract the 3D structure of the marker points set, and then the 3D structure is deconstructed into 2D units for matching, which simplifies complexity and improves the efficiency of the algorithm. In the verification process, the mismatched pairs of points are located and removed by the method that is based on the error dispersion of initial matched results, and the initial transformation results are iteratively verified to obtain the optimal transformation matrix. The experimental results show that our method takes an average of 2.2 s for each matching, the average error of coarse registration point cloud is 0.075 mm and the root mean square is 0.219 mm, which effectively solves the problem of the low efficiency and accuracy of marker points 3D matching methods.


  • A deep-learning based high-accuracy camera calibration method for large-scale scene

    by Qiongqiong Duan, Zhao Wang, Junhui Huang, Chao Xing, Zijun Li, Miaowei Qi, Jianmin Gao, Song Ai


  • Blade profile extraction and edge completion method based on structured light measurement point cloud

    by Zijun Li, Zhao Wang, Junhui Huang, Qiongqiong Duan, Miaowei Qi, Jianmin Gao, Wei Wang, Qiang Dong, Qiyuan Li, Song Ai


  • High precision measurement for the chamfered hole radius and spacing of a large-size workpiece based on binocular vision combined with plane dynamic adjustment

    by Junhui Huang, Miaowei Qi, Zhao Wang, Chao Xing, Jianmin Gao

    A novel, to the best of our knowledge, hole radius and spacing measurement method is presented based on binocular vision combined with dynamic local plane for the large-size workpiece with plane feature. The novel method overcomes the problem of the ariable working distance and large location error of an abrupt edge for conventional methods. Its measurement principle and model are introduced. Then, a chamfered inner edge extraction method based on the shrinkage of an elliptical band and an adaptive weight optimal calculation based on redundant measurement data are presented to improve the measurement accuracy. Experiments are carried out to validate the presented method, and a high measurement accuracy with a standard deviation of 0.017 mm in the hole radius and 0.021 mm in hole spacing have eventually been achieved for the actual measurement workpieces, respectively. Compared with the common method, the measurement accuracy is improved by at least 77% and 53% in radius and spacing, respectively.


  • Resolution-enhanced heterodyne laser interferometer with differential configuration for roll angle measurement

    by Jingya Qi, Zhao Wang, Junhui Huang, Jianmin Gao

    A high resolution roll measurement heterodyne interferometer with differential configurations is proposed in this paper. The proposed interferometer is composed of a pair of measurement beams providing environmental noise immunity. The structure is designed and the mathematic model based on Jones’ matrix for measuring the roll angle is established. Sensitivity is enhanced dramatically because of the opposite phase shift directions of two signals. An experimental setup is built and an amplification factor of 270 is obtained. Correspondingly, a roll angle resolution of 0.13 arcsec is attained using a phase meter with detecting resolution of 0.01°.


  • Error of image saturation in the structured-light method

    by Zhaoshuai Qi, Zhao Wang, Junhui Huang, Chao Xing, Jianmin Gao

    In the phase-measuring structured-light method, image saturation will induce large phase errors. Usually, by selecting proper system parameters (such as the phase-shift number, exposure time, projection intensity, etc.), the phase error can be reduced. However, due to lack of a complete theory of phase error, there is no rational principle or basis for the selection of the optimal system parameters. For this reason, the phase error due to image saturation is analyzed completely, and the effects of the two main factors, including the phase-shift number and saturation degree, on the phase error are studied in depth. In addition, the selection of optimal system parameters is discussed, including the proper range and the selection principle of the system parameters. The error analysis and the conclusion are verified by simulation and experiment results, and the conclusion can be used for optimal parameter selection in practice.


  • Open Access

    High-Precision Registration of Point Clouds Based on Sphere Feature Constraints

    by Junhui Huang, Zhao Wang, Jianmin Gao, Youping Huang, David Peter Towers

    Point cloud registration is a key process in multi-view 3D measurements. Its precision affects the measurement precision directly. However, in the case of the point clouds with non-overlapping areas or curvature invariant surface, it is difficult to achieve a high precision. A high precision registration method based on sphere feature constraint is presented to overcome the difficulty in the paper. Some known sphere features with constraints are used to construct virtual overlapping areas. The virtual overlapping areas provide more accurate corresponding point pairs and reduce the influence of noise. Then the transformation parameters between the registered point clouds are solved by an optimization method with weight function. In that case, the impact of large noise in point clouds can be reduced and a high precision registration is achieved. Simulation and experiments validate the proposed method.


  • Open Access

    Analysis and Compensation for Lateral Chromatic Aberration in a Color Coding Structured Light 3D Measurement System

    by Junhui Huang, Qi Xue, Zhao Wang, Jianmin Gao

    While color-coding methods have improved the measuring efficiency of a structured light three-dimensional (3D) measurement system, they decreased the measuring accuracy significantly due to lateral chromatic aberration (LCA). In this study, the LCA in a structured light measurement system is analyzed, and a method is proposed to compensate the error caused by the LCA. Firstly, based on the projective transformation, a 3D error map of LCA is constructed in the projector images by using a flat board and comparing the image coordinates of red, green and blue circles with the coordinates of white circles at preselected sample points within the measurement volume. The 3D map consists of the errors, which are the equivalent errors caused by LCA of the camera and projector. Then in measurements, error values of LCA are calculated and compensated to correct the projector image coordinates through the 3D error map and a tri-linear interpolation method. Eventually, 3D coordinates with higher accuracy are re-calculated according to the compensated image coordinates. The effectiveness of the proposed method is verified in the following experiments.


  • Open Access

    Modeling and Analysis of Phase Fluctuation in a High-Precision Roll Angle Measurement Based on a Heterodyne Interferometer

    by Junhui Huang, Zhao Wang, Jianmin Gao, Bao Yu

    Heterodyne interferometry is a high-precision method applied in roll angle measurements. Phase metering is essential for high precision. During a high-precision measurement, a phase fluctuation appears even when the roll angle does not vary, which has never been analyzed before. Herein, the reason for the phase fluctuation is revealed, which results from the frequency-difference fluctuation and time difference between measurement and reference beams. A mathematical model of that phase-fluctuation mechanism is established, and that model provides a theoretical basis for analyzing and reducing the phase fluctuation. The impact that the main factors have on the phase metering is analyzed quantitatively, and experiments are carried out to validate the model. Finally, the phase fluctuation decreases to 0.02° by frequency reduction, which conversely verifies the theoretical model.