Jiuqing Cai
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Jiuqing Cai has a total of 25 co-authors. Here are the top co-authors by number of shared publications:
- Changsong Chen
State Key Laboratory of Advanced Electromagnetic Technology, School of Electrical and Electronic Engineering, Huazhong University of Science and Technology, Wuhan, China
3 shared publications - Shanxu Duan
State Key Laboratory of Advanced Electromagnetic Technology, School of Electrical and Electronic Engineering, Huazhong University of Science and Technology, Wuhan, China
3 shared publications - Jing Chen
Wuhan Second Ship Design and Research Institute, Wuhan, China
2 shared publications - Rui Li
Hubei Key Laboratory of Marine Electromagnetic Detection and Control, Wuhan 430205, China
2 shared publications - Shuai Yu
Wuhan Second Ship Design and Research Institute, Wuhan, China
2 shared publications - Weilong Zhang
Hubei Key Laboratory of Marine Electromagnetic Detection and Control, Wuhan 430205, China
2 shared publications
Latest Publications
- 14 August 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 39 (12) , 16187-16200
A Calculation Method of IGBT Insulation Voltages Based on Submodule Stray Capacitors in MMC
In practical modular multilevel converter (MMC) engineering, the dc voltage can be as high as tens to hundreds of kV, while the insulated gate bipolar transistors (IGBTs) isolation voltage is only several kV. The extreme high voltage of MMC can easily destroy the ceramic layers of the IGBT. To assess the IGBT insulation voltages and help design insulation protection measures in the early design stage of MMC, this article proposes a submodule stray capacitor based calculation method for IGBT insulation voltages. First, the switching-states and the stray capacitor model of submodules are introduced. Then, the IGBT insulation voltages are derived in detail, and the voltage characteristics under normal and fault conditions are analyzed. After that, the effect of the heatsink-to-ground capacitance on the maximum IGBT insulation voltages is discussed. The proposed method has a good accuracy with most relative errors less than 5% (calculation versus simulation) and 20% (calculation versus experiment). To protect the insulation safety of IGBTs, this article also gives a design example of the maximum heatsink-to-ground stray capacitance. The proposed method can not only guide the IGBT insulation protection design, but also provide the model reference and the heatsink-to-ground voltage estimation for the EMI researches of MMC.
- 14 August 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 39 (12) , 16187-16200
A Calculation Method of IGBT Insulation Voltages Based on Submodule Stray Capacitors in MMC
In practical modular multilevel converter (MMC) engineering, the dc voltage can be as high as tens to hundreds of kV, while the insulated gate bipolar transistors (IGBTs) isolation voltage is only several kV. The extreme high voltage of MMC can easily destroy the ceramic layers of the IGBT. To assess the IGBT insulation voltages and help design insulation protection measures in the early design stage of MMC, this article proposes a submodule stray capacitor based calculation method for IGBT insulation voltages. First, the switching-states and the stray capacitor model of submodules are introduced. Then, the IGBT insulation voltages are derived in detail, and the voltage characteristics under normal and fault conditions are analyzed. After that, the effect of the heatsink-to-ground capacitance on the maximum IGBT insulation voltages is discussed. The proposed method has a good accuracy with most relative errors less than 5% (calculation versus simulation) and 20% (calculation versus experiment). To protect the insulation safety of IGBTs, this article also gives a design example of the maximum heatsink-to-ground stray capacitance. The proposed method can not only guide the IGBT insulation protection design, but also provide the model reference and the heatsink-to-ground voltage estimation for the EMI researches of MMC.
- 28 November 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 39 (2) , 2226-2236
Multiobjective Optimization Considering PET's Vibration Suppression of Dual Active Bridge Converter Based on BP-NSGA-II
The article proposes a multiobjective optimization procedure for a dual active bridge (DAB) converter based on nondominated sorting genetic algorithm with back propagation (BP) neural network embedded in back propagation nondominated sorting genetic algorithm (BP-NSGA-II), where the BP neural network was used to predict the vibration of power electronic transformer (PET). Experimental results demonstrate the high accuracy of this neural network in vibration fitting of PET. Based on the offline trained neural network, the phase-shift angles corresponding to minimum vibration is found in the triple phase-shift mode of DAB. Compared with common phase-shift modes at the same transmission power level, the optimized method could effectively reduce the vibration amplitude of PET at the key frequency with more than 20 dB. Meanwhile, the vibration amplitude at the concerned frequency of the optimized method is smaller than that of all the training sets. Furthermore, in BP-NSGA-II, the current stress, reflow power, and vibration of PET are used as objective functions to optimize the operating state of DAB further. The experimental results show that the proposed multiobjective optimization method, based on BP-NSGA-II, can improve the performance of the DAB converter by reducing its current stress and reflow power while suppressing the vibration amplitude of PET.
- 28 November 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 39 (2) , 2226-2236
Multiobjective Optimization Considering PET's Vibration Suppression of Dual Active Bridge Converter Based on BP-NSGA-II
The article proposes a multiobjective optimization procedure for a dual active bridge (DAB) converter based on nondominated sorting genetic algorithm with back propagation (BP) neural network embedded in back propagation nondominated sorting genetic algorithm (BP-NSGA-II), where the BP neural network was used to predict the vibration of power electronic transformer (PET). Experimental results demonstrate the high accuracy of this neural network in vibration fitting of PET. Based on the offline trained neural network, the phase-shift angles corresponding to minimum vibration is found in the triple phase-shift mode of DAB. Compared with common phase-shift modes at the same transmission power level, the optimized method could effectively reduce the vibration amplitude of PET at the key frequency with more than 20 dB. Meanwhile, the vibration amplitude at the concerned frequency of the optimized method is smaller than that of all the training sets. Furthermore, in BP-NSGA-II, the current stress, reflow power, and vibration of PET are used as objective functions to optimize the operating state of DAB further. The experimental results show that the proposed multiobjective optimization method, based on BP-NSGA-II, can improve the performance of the DAB converter by reducing its current stress and reflow power while suppressing the vibration amplitude of PET.
- Open Access
- 12 May 2023
- Published by MDPI AG in Electronics
- Vol. 12 (10) , 2209
Modeling and Centralized-ZVS Control for Wireless Charging Electric Vehicles Supplied by Parallel Modular Multi-Inverters
In this paper, a parallel modular multi-inverter (PMMI) topology is proposed to supply high power for wireless charging electric vehicles (EVs). A major challenge in the implementation of PMMI topology is zero-voltage switching (ZVS) for all inverters to avoid high-frequency switching losses. Therefore, a centralized-ZVS control and master–slave frequency following (MSFF) strategy are presented to realize ZVS for all PMMIs by a single controller structure without extra controllers needed on the slave inverters. Meanwhile, a modeling method directly related to the ZVS angle and operating frequency for an arbitrary number of PMMIs is proposed and linearized to analyze the system dynamic characteristics at the operating point. Additionally, to obtain the desired dynamic performance, an optimal controller coefficient (OCC) configuration method is proposed for the design of controller parameters. Finally, a laboratory wireless power transfer (WPT) prototype supplied by three PMMIs is designed, built, and tested to verify the correctness of the theoretical analysis. Experimental results show that the ZVS angle of all PMMIs can maintain at the preset value with the desired settling time under designed the PI controller parameters. The measured whole system power transmission efficiency is at a 10 load.- 12 May 2023
- Published by MDPI AG in Electronics
- Vol. 12 (10) , 2209
Open AccessModeling and Centralized-ZVS Control for Wireless Charging Electric Vehicles Supplied by Parallel Modular Multi-Inverters
In this paper, a parallel modular multi-inverter (PMMI) topology is proposed to supply high power for wireless charging electric vehicles (EVs). A major challenge in the implementation of PMMI topology is zero-voltage switching (ZVS) for all inverters to avoid high-frequency switching losses. Therefore, a centralized-ZVS control and master–slave frequency following (MSFF) strategy are presented to realize ZVS for all PMMIs by a single controller structure without extra controllers needed on the slave inverters. Meanwhile, a modeling method directly related to the ZVS angle and operating frequency for an arbitrary number of PMMIs is proposed and linearized to analyze the system dynamic characteristics at the operating point. Additionally, to obtain the desired dynamic performance, an optimal controller coefficient (OCC) configuration method is proposed for the design of controller parameters. Finally, a laboratory wireless power transfer (WPT) prototype supplied by three PMMIs is designed, built, and tested to verify the correctness of the theoretical analysis. Experimental results show that the ZVS angle of all PMMIs can maintain at the preset value with the desired settling time under designed the PI controller parameters. The measured whole system power transmission efficiency is at a 10 load. - Open Access
- 17 April 2023
- Published by MDPI AG in Electronics
- Vol. 12 (8) , 1898
Anti-Offset High-Voltage Wireless Power Transfer System Based on Many-to-One Topology
Aiming at the problems of limited semiconductor performance and positioning difficulties in the wireless power transfer (WPT) system of electric vehicles, the paper proposes a many-to-one high-voltage wireless charging anti-offset system. In order to be adapted to high-voltage applications, the system is designed with a series input inverter. At the same time, a multi-winding transformer is used to realize the equivalent parallel output of inverters and the function of transmitting power to primary loops. The many-to-one topology aims to expand the positioning range of electric vehicles to realize the anti-offset of wireless charging. In order to analyze the working mechanism of the multi-winding transformer and study the power transmission characteristics of the many-to-one topology, the equivalent circuit analysis and Matlab simulation are carried out, and a laboratory prototype for experimental verification is made. Based on the experimental and simulation results, the paper proposes a hybrid operating mode based on many-to-one WPT topology, which can effectively expand the positioning range of electric vehicles during wireless charging. Both the analytical and experimental results show that the topology proposed in the paper can effectively increase the input voltage of the system for high-voltage scenarios, and effectively expand the positioning range of the WPT system.
- 17 April 2023
- Published by MDPI AG in Electronics
- Vol. 12 (8) , 1898
Open AccessAnti-Offset High-Voltage Wireless Power Transfer System Based on Many-to-One Topology
Aiming at the problems of limited semiconductor performance and positioning difficulties in the wireless power transfer (WPT) system of electric vehicles, the paper proposes a many-to-one high-voltage wireless charging anti-offset system. In order to be adapted to high-voltage applications, the system is designed with a series input inverter. At the same time, a multi-winding transformer is used to realize the equivalent parallel output of inverters and the function of transmitting power to primary loops. The many-to-one topology aims to expand the positioning range of electric vehicles to realize the anti-offset of wireless charging. In order to analyze the working mechanism of the multi-winding transformer and study the power transmission characteristics of the many-to-one topology, the equivalent circuit analysis and Matlab simulation are carried out, and a laboratory prototype for experimental verification is made. Based on the experimental and simulation results, the paper proposes a hybrid operating mode based on many-to-one WPT topology, which can effectively expand the positioning range of electric vehicles during wireless charging. Both the analytical and experimental results show that the topology proposed in the paper can effectively increase the input voltage of the system for high-voltage scenarios, and effectively expand the positioning range of the WPT system.
- 1 September 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 18 (23293721) , 1238-1242
Stability analysis of instantaneous average current sharing control strategy for parallel operation of UPS modules
This paper discusses and analyzes the parallel operation of uninterruptible power supplies (UPS) with instantaneous average current sharing control strategy. The analysis demonstrate that the control method introduces a virtual impedance between the inverters. If the impedance configured as resistive, it will simplify the control strategy, the paper analyzes the stability of the control system by changing the control diagram from voltage-source mode to current-source mode, precise stable condition has been obtained considering the varying line inductance. Simulation models and several experimental 220V/2kVA inverters are built and paralleled to verify the theoretical predictions.
- 1 September 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 18 (23293721) , 1238-1242
Stability analysis of instantaneous average current sharing control strategy for parallel operation of UPS modules
This paper discusses and analyzes the parallel operation of uninterruptible power supplies (UPS) with instantaneous average current sharing control strategy. The analysis demonstrate that the control method introduces a virtual impedance between the inverters. If the impedance configured as resistive, it will simplify the control strategy, the paper analyzes the stability of the control system by changing the control diagram from voltage-source mode to current-source mode, precise stable condition has been obtained considering the varying line inductance. Simulation models and several experimental 220V/2kVA inverters are built and paralleled to verify the theoretical predictions.
- Open Access
- 7 May 2015
- Published by Springer Nature in Journal of Modern Power Systems and Clean Energy
- Vol. 3 (2) , 269-276
Centralized control of parallel connected power conditioning system in electric vehicle charge–discharge and storage integration station
- 7 May 2015
- Published by Springer Nature in Journal of Modern Power Systems and Clean Energy
- Vol. 3 (2) , 269-276
Open AccessCentralized control of parallel connected power conditioning system in electric vehicle charge–discharge and storage integration station
- 1 September 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 26 (23293721) , 409-413
Centralized control of large capacity parallel connected power conditioning system for battery energy storage system in microgrid
This paper presents a centralized control scheme that coordinates parallel operations of large capacity power conditioning system (PCS) for battery energy storage system (BESS) in Micro-grid (MG). The theoretical analysis of the different operation modes are studied, including grid-connected mode, islanded mode and transfer mode. To improve the power sharing accuracy during the islanded operation, a parallel control strategy based on communication network is applied in large-capacity system. Moreover, a novel seamless transfer method is proposed to implement three-phase PCS transition between grid-connected mode and islanded mode. Simulation and experimental results are provided to validate the feasibility of the proposed control strategy.
- 1 September 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 26 (23293721) , 409-413
Centralized control of large capacity parallel connected power conditioning system for battery energy storage system in microgrid
This paper presents a centralized control scheme that coordinates parallel operations of large capacity power conditioning system (PCS) for battery energy storage system (BESS) in Micro-grid (MG). The theoretical analysis of the different operation modes are studied, including grid-connected mode, islanded mode and transfer mode. To improve the power sharing accuracy during the islanded operation, a parallel control strategy based on communication network is applied in large-capacity system. Moreover, a novel seamless transfer method is proposed to implement three-phase PCS transition between grid-connected mode and islanded mode. Simulation and experimental results are provided to validate the feasibility of the proposed control strategy.