Josh G. Nowlan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Josh G. Nowlan has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Phillip J. Wallace
Brock University
2 shared publications - Stephen S. Cheung
Environmental Ergonomics Laboratory, Department of Kinesiology, Brock University, St. Catharines, ON, Canada
2 shared publications - Christopher James Tyler
University of Roehampton
1 shared publication - Dominique D. Gagnon
Laboratory of Environmental Exercise Physiology, School of Human Kinetics, Laurentian University, Sudbury, ON, Canada
1 shared publication - Geoffrey L. Hartley
Nipissing University
1 shared publication Johnathan Ljubanovich
Environmental Ergonomics Laboratory, Department of Kinesiology, Brock University, St. Catharines, Ontario, Canada
1 shared publication
Latest Publications
- 1 January 2026
- Published by Human Kinetics in International Journal of Sports Physiology and Performance
- Vol. -1 (aop) , 1-7
Hand and Forearm Cooling Alters Perceptual Comfort but Not Self-Paced Cycling Performance in the Heat
Purpose : We tested the effectiveness of hand and forearm per-cooling on self-paced cycling performance in the heat. We hypothesized that continuous, localized cooling would attenuate thermal strain and improve thermal perception, thereby enhancing performance. Methods : Ten trained cyclists (7 males and 3 females; 34 [12] y, 174.4 [8.2] cm, 75.5 [10.6] kg, 55.3 [10.7] mL·kg −1 ·min −1 ) completed 3 randomized 20-km cycling time trials in the heat (35 °C, 50% relative humidity) while immersing their forearms and hands in a circulating water bath at 10 °C, 20 °C, or 32 °C (control) throughout. Results : Whole-body thermal comfort was significantly reduced in the 10 °C and 20 °C trials compared with the 32 °C trial (both P ≤ .005). However, time to completion did not improve with either 10 °C (36.6 [2.1] min) or 20 °C (36.8 [2.2] min) compared with control (37.0 [1.9] min, P = .476), nor did power output (10 °C: 202 [39] W, 20 °C: 201 [42] W, 32 °C: 202 [37] W; P = .988) or pacing strategy. Physiological strain was also not different across conditions for both mean heart rate ( P = .535) and rectal temperature change (10 °C: +1.3 [0.7] °C, 20 °C: +1.3 [0.5] °C, 32 °C: +1.5 [0.4] °C; P = .153). Conclusion : Despite perceptual benefits, passive water immersion of the extremities did not improve time-trial performance and appears insufficient to lower the physiological strain experienced during a self-paced 20-km time trial in the heat.
- 1 January 2026
- Published by Human Kinetics in International Journal of Sports Physiology and Performance
- Vol. -1 (aop) , 1-7
Hand and Forearm Cooling Alters Perceptual Comfort but Not Self-Paced Cycling Performance in the Heat
Purpose : We tested the effectiveness of hand and forearm per-cooling on self-paced cycling performance in the heat. We hypothesized that continuous, localized cooling would attenuate thermal strain and improve thermal perception, thereby enhancing performance. Methods : Ten trained cyclists (7 males and 3 females; 34 [12] y, 174.4 [8.2] cm, 75.5 [10.6] kg, 55.3 [10.7] mL·kg −1 ·min −1 ) completed 3 randomized 20-km cycling time trials in the heat (35 °C, 50% relative humidity) while immersing their forearms and hands in a circulating water bath at 10 °C, 20 °C, or 32 °C (control) throughout. Results : Whole-body thermal comfort was significantly reduced in the 10 °C and 20 °C trials compared with the 32 °C trial (both P ≤ .005). However, time to completion did not improve with either 10 °C (36.6 [2.1] min) or 20 °C (36.8 [2.2] min) compared with control (37.0 [1.9] min, P = .476), nor did power output (10 °C: 202 [39] W, 20 °C: 201 [42] W, 32 °C: 202 [37] W; P = .988) or pacing strategy. Physiological strain was also not different across conditions for both mean heart rate ( P = .535) and rectal temperature change (10 °C: +1.3 [0.7] °C, 20 °C: +1.3 [0.5] °C, 32 °C: +1.5 [0.4] °C; P = .153). Conclusion : Despite perceptual benefits, passive water immersion of the extremities did not improve time-trial performance and appears insufficient to lower the physiological strain experienced during a self-paced 20-km time trial in the heat.
- 1 January 2024
- Published by American Physiological Society in Journal of Applied Physiology
- Vol. 136 (1) , 58-69
Endurance capacity impairment in cold air ranging from skin cooling to mild hypothermia
We developed a novel protocol that cooled skin temperature, or skin plus core temperature (Δ−0.5°C or Δ−1.0 °C), to determine a dose-response of cold exposure on endurance capacity at 70% peak power output. Skin cooling significantly impaired exercise tolerance time by ∼31%, whereas core cooling led to a further reduction of 30%–40% with no difference between Δ−0.5°C and Δ−1.0°C. Overall, simply cooling the skin impaired endurance capacity, but this impairment is further magnified by core cooling.
- 1 January 2024
- Published by American Physiological Society in Journal of Applied Physiology
- Vol. 136 (1) , 58-69
Endurance capacity impairment in cold air ranging from skin cooling to mild hypothermia
We developed a novel protocol that cooled skin temperature, or skin plus core temperature (Δ−0.5°C or Δ−1.0 °C), to determine a dose-response of cold exposure on endurance capacity at 70% peak power output. Skin cooling significantly impaired exercise tolerance time by ∼31%, whereas core cooling led to a further reduction of 30%–40% with no difference between Δ−0.5°C and Δ−1.0°C. Overall, simply cooling the skin impaired endurance capacity, but this impairment is further magnified by core cooling.