Xiaojuan Li
Research Subjects
Xiaojuan Li has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
- Jianjun Cui
National Institute of Metrology, Beijing 100029, China
2 shared publications - Kai Chen
National Institute of Metrology, Beijing 100029, China
2 shared publications - Peijie Song
School of Electrical Engineering, Lanzhou Jiaotong University 1 , Lanzhou 730070, China
2 shared publications - Yandong Chu
School of Electrical Engineering, Lanzhou Jiaotong University, Lanzhou 730070, China
2 shared publications
Latest Publications
- Open Access
- 29 March 2024
- Published by MDPI AG in Applied Sciences
- Vol. 14 (7) , 2910
The Impact of the Damping Coefficient on the Dynamic Stability of the TM-AFM Microcantilever Beam System
The tapping-mode atomic force microscope (TM-AFM) is widely used today; however, improper matching between the operating medium and the sampling time may lead to inaccurate measurement results. The relationship between the damping coefficient and the steady state of the TM-AFM microcantilever is investigated in this paper using multiple stability theory. Firstly, the effects of changes in dimensionless linear damping coefficients and dimensionless piezoelectric film damping coefficients on the motion stability of the system are examined using bifurcation diagrams, phase trajectories, and domains of attraction. Subsequently, the degrees of effect of the two damping coefficients on the stability of the system are compared. Finally, the bi-parametric bifurcation characteristics of the system under a specific number of iterative cycles are investigated using the bi-parametric bifurcation diagram in conjunction with the actual working conditions, and the boundary conditions for the transition of the system’s motion from an unstable state to a stable state are obtained. The results of the study show that to ensure the accuracy and reliability of the individual measurement data in 500 iteration cycles, the dimensionless linear damping coefficient must be greater than 0.01014. Our results will provide valuable references for TM-AFM measurement media selection, improving TM-AFM imaging quality, measurement accuracy and maneuverability, and TM-AFM troubleshooting.
- 29 March 2024
- Published by MDPI AG in Applied Sciences
- Vol. 14 (7) , 2910
Open AccessThe Impact of the Damping Coefficient on the Dynamic Stability of the TM-AFM Microcantilever Beam System
The tapping-mode atomic force microscope (TM-AFM) is widely used today; however, improper matching between the operating medium and the sampling time may lead to inaccurate measurement results. The relationship between the damping coefficient and the steady state of the TM-AFM microcantilever is investigated in this paper using multiple stability theory. Firstly, the effects of changes in dimensionless linear damping coefficients and dimensionless piezoelectric film damping coefficients on the motion stability of the system are examined using bifurcation diagrams, phase trajectories, and domains of attraction. Subsequently, the degrees of effect of the two damping coefficients on the stability of the system are compared. Finally, the bi-parametric bifurcation characteristics of the system under a specific number of iterative cycles are investigated using the bi-parametric bifurcation diagram in conjunction with the actual working conditions, and the boundary conditions for the transition of the system’s motion from an unstable state to a stable state are obtained. The results of the study show that to ensure the accuracy and reliability of the individual measurement data in 500 iteration cycles, the dimensionless linear damping coefficient must be greater than 0.01014. Our results will provide valuable references for TM-AFM measurement media selection, improving TM-AFM imaging quality, measurement accuracy and maneuverability, and TM-AFM troubleshooting.
- Open Access
Investigation on the Impact of Excitation Amplitude on AFM-TM Microcantilever Beam System’s Dynamic Characteristics and Implementation of an Equivalent Circuit
Alterations in the dynamical properties of an atomic force microscope microcantilever beam system in tapping mode can appreciably impact its measurement precision. Understanding the influence mechanism of dynamic parameter changes on the system’s motion characteristics is vital to improve the accuracy of the atomic force microscope in tapping mode (AFM-TM). In this study, we categorize the mathematical model of the AFM-TM microcantilever beam system into systems 1 and 2 based on actual working conditions. Then, we analyze the alterations in the dynamic properties of both systems due to external excitation variations using bifurcation diagrams, phase trajectories, Lyapunov indices, and attraction domains. The numerical simulation results show that when the dimensionless external excitation g < 0.183, the motion state of system 2 is period 1. When g < 0.9, the motion state of system 1 is period 1 motion. Finally, we develop the equivalent circuit model of the AFM-TM microcantilever beam and perform related software simulations, along with practical circuit experiments. Our experimental results indicate that the constructed equivalent circuit can effectively analyze the dynamic characteristics of the AFM-TM microcantilever beam system in the presence of complex external environmental factors. It is observed that the practical circuit simulation attenuates high-frequency signals, resulting in a 31.4% reduction in excitation amplitude compared to numerical simulation results. This provides an essential theoretical foundation for selecting external excitation parameters for AFM-TM cantilever beams and offers a novel method for analyzing the dynamics of micro- and nanomechanical systems, as well as other nonlinear systems.
Open AccessInvestigation on the Impact of Excitation Amplitude on AFM-TM Microcantilever Beam System’s Dynamic Characteristics and Implementation of an Equivalent Circuit
Alterations in the dynamical properties of an atomic force microscope microcantilever beam system in tapping mode can appreciably impact its measurement precision. Understanding the influence mechanism of dynamic parameter changes on the system’s motion characteristics is vital to improve the accuracy of the atomic force microscope in tapping mode (AFM-TM). In this study, we categorize the mathematical model of the AFM-TM microcantilever beam system into systems 1 and 2 based on actual working conditions. Then, we analyze the alterations in the dynamic properties of both systems due to external excitation variations using bifurcation diagrams, phase trajectories, Lyapunov indices, and attraction domains. The numerical simulation results show that when the dimensionless external excitation g < 0.183, the motion state of system 2 is period 1. When g < 0.9, the motion state of system 1 is period 1 motion. Finally, we develop the equivalent circuit model of the AFM-TM microcantilever beam and perform related software simulations, along with practical circuit experiments. Our experimental results indicate that the constructed equivalent circuit can effectively analyze the dynamic characteristics of the AFM-TM microcantilever beam system in the presence of complex external environmental factors. It is observed that the practical circuit simulation attenuates high-frequency signals, resulting in a 31.4% reduction in excitation amplitude compared to numerical simulation results. This provides an essential theoretical foundation for selecting external excitation parameters for AFM-TM cantilever beams and offers a novel method for analyzing the dynamics of micro- and nanomechanical systems, as well as other nonlinear systems.