Rujie Liu
Rujie Liu has a total of 34 co-authors. Here are the top co-authors by number of shared publications:
- Tao Han
Three Gorges Electric Power Co., Ltd., Wuhan 430021, China
3 shared publications - Wei He
China Yangtze Power Co., Ltd., Beijing 100032, China
3 shared publications - Yongqiang Luo
School of Environmental Science and Engineering, Huazhong University of Science and Technology, Wuhan 430074, China
3 shared publications - Yuce Liu
China Three Gorges Corporation, Wuhan 430010, China
3 shared publications - Yue Hu
CTG Wuhan Science and Technology Innovation Park, China Three Gorges Corporation, Wuhan 430010, China
3 shared publications - Chaohui Zhou
CTG Wuhan Science and Technology Innovation Park, China Three Gorges Corporation, Wuhan 430010, China
2 shared publications
Latest Publications
- Open Access
Experimental Study on Performance of a Containerized 3 MWh High-Temperature Solid Heat Storage and Heat Supply System
Containerized high-temperature solid heat storage is a promising solution for flexible co-supply of steam and hot water. This paper conducts an experimental study on a 3 MWh containerized high-temperature solid heat storage and supply system, which can simultaneously provide saturated/superheated steam and hot water. High-density magnesia bricks are used as the thermal storage medium and heated to over 800 °C using off-peak electricity or curtailed renewable energy. Circulating air is driven through the saturated and superheated exchange sections successively by variable-frequency fans, realizing on-demand output of thermal energy. The size of the integrated equipment is 11.8 m × 2.13 m × 2.18 m. Experiments were conducted under direct electric heating mode and thermal storage mode. In direct electric heating mode, the storage is kept at 900 °C. As the circulating air flow increases, the inlet/outlet air temperature difference decreases from 600 °C to 300 °C at the saturated section, and from 350 °C to 70 °C at the superheated section, whereas the output power is increased. In thermal storage mode, an adaptive air-volume regulation strategy was used to maintain stable-power release despite the temperature drop of storage bricks. A complete 24 h storage/release cycle test shows that the effective heat storage capacity is 3.14 MWh, the electro-thermal conversion efficiency is 97.84%, and the superheated steam above 450 °C can be stably supplied.
Open AccessExperimental Study on Performance of a Containerized 3 MWh High-Temperature Solid Heat Storage and Heat Supply System
Containerized high-temperature solid heat storage is a promising solution for flexible co-supply of steam and hot water. This paper conducts an experimental study on a 3 MWh containerized high-temperature solid heat storage and supply system, which can simultaneously provide saturated/superheated steam and hot water. High-density magnesia bricks are used as the thermal storage medium and heated to over 800 °C using off-peak electricity or curtailed renewable energy. Circulating air is driven through the saturated and superheated exchange sections successively by variable-frequency fans, realizing on-demand output of thermal energy. The size of the integrated equipment is 11.8 m × 2.13 m × 2.18 m. Experiments were conducted under direct electric heating mode and thermal storage mode. In direct electric heating mode, the storage is kept at 900 °C. As the circulating air flow increases, the inlet/outlet air temperature difference decreases from 600 °C to 300 °C at the saturated section, and from 350 °C to 70 °C at the superheated section, whereas the output power is increased. In thermal storage mode, an adaptive air-volume regulation strategy was used to maintain stable-power release despite the temperature drop of storage bricks. A complete 24 h storage/release cycle test shows that the effective heat storage capacity is 3.14 MWh, the electro-thermal conversion efficiency is 97.84%, and the superheated steam above 450 °C can be stably supplied.
- Open Access
- 25 August 2026
- Published by MDPI AG in Sustainability
- Vol. 18 (17) , 8707
Shallow–Deep Mixed Ground Source Heat Pump System for Sustainable Heating and Cooling: From a Small-Size Experimental Study to Evaluation of Its Interaction with the Grid
Ground source heat pump (GSHP) systems contribute to sustainable building decarbonization while confronting two intertwined challenges: long-term ground thermal imbalance in shallow borefields and the requirement for coordinated operation between thermal systems and electrical grid dynamics. Hybrid shallow–deep borefield configurations have been proposed to mitigate thermal imbalance for sustainable geothermal resource exploitation, yet their grid-interactive demand–response potential remains unexplored. Here, we develop a coupled thermal–electrical model for a shallow–deep mixed GSHP (SDBHE) system equipped with water-tank thermal storage, validated against scaled sand-tank experiments (3.5–8.3% error), and assess its year-round performance under time-of-use electricity tariffs for a 200,000 m2 residential district in cold-climate conditions. The SDBHE system reduces the required shallow borehole count by 28% and total drilling length by 22% compared with a shallow-only baseline, saving 11% on operational electricity costs over 10 years. Integrating water-tank thermal storage with a 50% load-shifting strategy yields an additional 10.9–11% cost reduction without degrading the system’s coefficient of performance. Under higher load-shifting ratios, the combined capital and operational savings reach 19–29%, with the optimal allocation assigning the incremental high-price-period load preferentially to deep boreholes (COP 6.29 versus 5.25 for shallow). These results demonstrate that integrating shallow and deep geothermal tiers with thermal storage enables both capital-efficient borefield design and economically viable demand-side grid participation. The findings are bound by the cold-climate residential context and the rule-based control scheme; field-scale validation and lifecycle cost analysis are needed to generalize the conclusions.
- 25 August 2026
- Published by MDPI AG in Sustainability
- Vol. 18 (17) , 8707
Open AccessShallow–Deep Mixed Ground Source Heat Pump System for Sustainable Heating and Cooling: From a Small-Size Experimental Study to Evaluation of Its Interaction with the Grid
Ground source heat pump (GSHP) systems contribute to sustainable building decarbonization while confronting two intertwined challenges: long-term ground thermal imbalance in shallow borefields and the requirement for coordinated operation between thermal systems and electrical grid dynamics. Hybrid shallow–deep borefield configurations have been proposed to mitigate thermal imbalance for sustainable geothermal resource exploitation, yet their grid-interactive demand–response potential remains unexplored. Here, we develop a coupled thermal–electrical model for a shallow–deep mixed GSHP (SDBHE) system equipped with water-tank thermal storage, validated against scaled sand-tank experiments (3.5–8.3% error), and assess its year-round performance under time-of-use electricity tariffs for a 200,000 m2 residential district in cold-climate conditions. The SDBHE system reduces the required shallow borehole count by 28% and total drilling length by 22% compared with a shallow-only baseline, saving 11% on operational electricity costs over 10 years. Integrating water-tank thermal storage with a 50% load-shifting strategy yields an additional 10.9–11% cost reduction without degrading the system’s coefficient of performance. Under higher load-shifting ratios, the combined capital and operational savings reach 19–29%, with the optimal allocation assigning the incremental high-price-period load preferentially to deep boreholes (COP 6.29 versus 5.25 for shallow). These results demonstrate that integrating shallow and deep geothermal tiers with thermal storage enables both capital-efficient borefield design and economically viable demand-side grid participation. The findings are bound by the cold-climate residential context and the rule-based control scheme; field-scale validation and lifecycle cost analysis are needed to generalize the conclusions.
- Open Access
Study on Quantifying Soil Thermal Imbalance in Shallow Coaxial Borehole Heat Exchangers
The bore field in ground source heat pump (GSHP) systems usually encounters thermal accumulation in long-term operation, but there is no quantitative index evaluating this process and its magnitude. A heat accumulation evaluation metric has been proposed, based on the linear trend Slope (°C/a) of the curve of soil temperature variation. Using this metric, the influence of various factors on soil temperature has been quantitatively analyzed. The results indicate that, under constant heating durations, each 10-day extension of cooling periods leads to an increase of 0.038 °C/a in soil temperature. Extending the recovery period within an annual cycle facilitates soil self-recovery and mitigates subsurface thermal accumulation. Increasing the spacing between boreholes effectively reduces thermal interference, whereas a greater number of boreholes exacerbates thermal accumulation. Deepening vertical boreholes from 100 m to 200 m reduces the average annual soil temperature increase by 0.1076 °C. Appropriately increasing backfill thermal conductivity enhances heat exchange efficiency and suppresses thermal accumulation. Higher water flow rates result in logarithmic increases in the evaluation metric, thereby intensifying soil thermal accumulation. Intermittent operation extends recovery periods, thereby alleviating soil thermal imbalance. Under balanced cooling and heating loads, increasing the system lifespan from 10 a to 30 a reduces the evaluation metric by 47.2%.
Open AccessStudy on Quantifying Soil Thermal Imbalance in Shallow Coaxial Borehole Heat Exchangers
The bore field in ground source heat pump (GSHP) systems usually encounters thermal accumulation in long-term operation, but there is no quantitative index evaluating this process and its magnitude. A heat accumulation evaluation metric has been proposed, based on the linear trend Slope (°C/a) of the curve of soil temperature variation. Using this metric, the influence of various factors on soil temperature has been quantitatively analyzed. The results indicate that, under constant heating durations, each 10-day extension of cooling periods leads to an increase of 0.038 °C/a in soil temperature. Extending the recovery period within an annual cycle facilitates soil self-recovery and mitigates subsurface thermal accumulation. Increasing the spacing between boreholes effectively reduces thermal interference, whereas a greater number of boreholes exacerbates thermal accumulation. Deepening vertical boreholes from 100 m to 200 m reduces the average annual soil temperature increase by 0.1076 °C. Appropriately increasing backfill thermal conductivity enhances heat exchange efficiency and suppresses thermal accumulation. Higher water flow rates result in logarithmic increases in the evaluation metric, thereby intensifying soil thermal accumulation. Intermittent operation extends recovery periods, thereby alleviating soil thermal imbalance. Under balanced cooling and heating loads, increasing the system lifespan from 10 a to 30 a reduces the evaluation metric by 47.2%.
- Open Access
Multi-Time-Scale Layered Energy Management Strategy for Integrated Production, Storage, and Supply Hydrogen Refueling Stations Based on Flexible Hydrogen Load Characteristics of Ports
Aiming at resolving the problem of stable and efficient operation of integrated green hydrogen production, storage, and supply hydrogen refueling stations at different time scales, this paper proposes a multi-time-scale hierarchical energy management strategy for integrated green hydrogen production, storage, and supply hydrogen refueling station (HFS). The proposed energy management strategy is divided into two layers. The upper layer uses the hourly time scale to optimize the operating power of HFS equipment with the goal of minimizing the typical daily operating cost, and proposes a parameter adaptive particle swarm optimization (PSA-PSO) solution algorithm that introduces Gaussian disturbance and adaptively adjusts the learning factor, inertia weight, and disturbance step size of the algorithm. Compared with traditional optimization algorithms, it can effectively improve the ability to search for the optimal solution. The lower layer uses the minute-level time scale to suppress the randomness of renewable energy power generation and hydrogen load consumption in the operation of HFS. A solution algorithm based on stochastic model predictive control (SMPC) is proposed. The Latin hypercube sampling (LHS) and simultaneous backward reduction methods are used to generate and reduce scenarios to obtain a set of high-probability random variable scenarios and bring them into the MPC to suppress the disturbance of random variables on the system operation. Finally, real operation data of a HFS in southern China are used for example analysis. The results show that the proposed energy management strategy has a good control effect in different typical scenarios.
Open AccessMulti-Time-Scale Layered Energy Management Strategy for Integrated Production, Storage, and Supply Hydrogen Refueling Stations Based on Flexible Hydrogen Load Characteristics of Ports
Aiming at resolving the problem of stable and efficient operation of integrated green hydrogen production, storage, and supply hydrogen refueling stations at different time scales, this paper proposes a multi-time-scale hierarchical energy management strategy for integrated green hydrogen production, storage, and supply hydrogen refueling station (HFS). The proposed energy management strategy is divided into two layers. The upper layer uses the hourly time scale to optimize the operating power of HFS equipment with the goal of minimizing the typical daily operating cost, and proposes a parameter adaptive particle swarm optimization (PSA-PSO) solution algorithm that introduces Gaussian disturbance and adaptively adjusts the learning factor, inertia weight, and disturbance step size of the algorithm. Compared with traditional optimization algorithms, it can effectively improve the ability to search for the optimal solution. The lower layer uses the minute-level time scale to suppress the randomness of renewable energy power generation and hydrogen load consumption in the operation of HFS. A solution algorithm based on stochastic model predictive control (SMPC) is proposed. The Latin hypercube sampling (LHS) and simultaneous backward reduction methods are used to generate and reduce scenarios to obtain a set of high-probability random variable scenarios and bring them into the MPC to suppress the disturbance of random variables on the system operation. Finally, real operation data of a HFS in southern China are used for example analysis. The results show that the proposed energy management strategy has a good control effect in different typical scenarios.
- Open Access
Energy Performance Study of a Data Center Combined Cooling System Integrated with Heat Storage and Waste Heat Recovery System
The energy efficiency of data centers has become an urgent problem as it is enjoying rapid development. This study proposes an integrated energy system involving a data center with different renewable energy sources and waste heat recovery, which can consider the partial and unsteady working load of data center. A dynamic and sophisticated system simulation model is established, which can provide both reliable and fast evaluations but also allow flexible extension of additional components. It is found that the free natural resource cooling system can cover about 28% of cooling demand. Compared to the reference condition, the proposed energy system achieves significant energy-saving benefits, with an energy-saving rate of 16.4%. The system COP increases from 3.88 to 4.64, and the PUE decreases from 1.36 to 1.30, resulting in a 23.45% reduction in electricity expenses. By integrating a waste heat recovery system, the heat pump can absorb approximately 3.57 million kWh of heat from the data center, providing approximately 4.587 million kWh of heating energy for users. The rooftop PV system generates approximately 370,000 kWh of electricity annually, covering approximately 8% of the total electricity consumption of the data center. This study can offer a new channel for the energy efficiency enhancement of data centers.
Open AccessEnergy Performance Study of a Data Center Combined Cooling System Integrated with Heat Storage and Waste Heat Recovery System
The energy efficiency of data centers has become an urgent problem as it is enjoying rapid development. This study proposes an integrated energy system involving a data center with different renewable energy sources and waste heat recovery, which can consider the partial and unsteady working load of data center. A dynamic and sophisticated system simulation model is established, which can provide both reliable and fast evaluations but also allow flexible extension of additional components. It is found that the free natural resource cooling system can cover about 28% of cooling demand. Compared to the reference condition, the proposed energy system achieves significant energy-saving benefits, with an energy-saving rate of 16.4%. The system COP increases from 3.88 to 4.64, and the PUE decreases from 1.36 to 1.30, resulting in a 23.45% reduction in electricity expenses. By integrating a waste heat recovery system, the heat pump can absorb approximately 3.57 million kWh of heat from the data center, providing approximately 4.587 million kWh of heating energy for users. The rooftop PV system generates approximately 370,000 kWh of electricity annually, covering approximately 8% of the total electricity consumption of the data center. This study can offer a new channel for the energy efficiency enhancement of data centers.
- Open Access
Cooperative Construction of Renewable Energy and Energy Storage System: Research on Evolutionary Game Model Based on Continuous Strategy and Random Disturbance
As the global push toward carbon neutrality accelerates, cooperation between power generation enterprises and energy storage companies plays a crucial role in the low-carbon transition of energy systems. However, there remains a lack of research on the stochastic dynamic mechanisms of cooperation evolution. This paper develops a stochastic evolutionary game model to analyze the cooperation evolution pathways between power generation enterprises and energy storage companies under different market parameter conditions. Sensitivity analysis is conducted to reveal the impact of factors such as market prices and power capacity on cooperation willingness. The results indicate that the dispatch optimization capability of storage technology and policy incentives significantly influence the willingness to cooperate. The study suggests that governments should enhance policy support and technological innovation to promote the sustainable development of energy systems.
Open AccessCooperative Construction of Renewable Energy and Energy Storage System: Research on Evolutionary Game Model Based on Continuous Strategy and Random Disturbance
As the global push toward carbon neutrality accelerates, cooperation between power generation enterprises and energy storage companies plays a crucial role in the low-carbon transition of energy systems. However, there remains a lack of research on the stochastic dynamic mechanisms of cooperation evolution. This paper develops a stochastic evolutionary game model to analyze the cooperation evolution pathways between power generation enterprises and energy storage companies under different market parameter conditions. Sensitivity analysis is conducted to reveal the impact of factors such as market prices and power capacity on cooperation willingness. The results indicate that the dispatch optimization capability of storage technology and policy incentives significantly influence the willingness to cooperate. The study suggests that governments should enhance policy support and technological innovation to promote the sustainable development of energy systems.
- Open Access
Application of Dynamic Weight Mixture Model Based on Dual Sliding Windows in Carbon Price Forecasting
As global climate change intensifies, nations around the world are implementing policies aimed at reducing emissions, with carbon-trading mechanisms emerging as a key market-based tool. China has launched carbon-trading markets in several cities, achieving significant trading volumes. Carbon-trading mechanisms encompass cap-and-trade markets and voluntary markets, influenced by various factors, including policy changes, economic conditions, energy prices, and climate fluctuations. The complexity of these factors, coupled with the nonlinear and non-stationary nature of carbon prices, makes forecasting a substantial challenge. This paper proposes a dynamic weight hybrid forecasting model based on a dual sliding window approach, effectively integrating multiple forecasting models such as LSTM, Random Forests, and LASSO. This model facilitates a thorough analysis of the influences of policy, market dynamics, technological advancements, and climatic conditions on carbon pricing. It serves as a potent tool for predicting carbon market price fluctuations and offers valuable decision support to stakeholders in the carbon market, ultimately aiding in the global efforts towards emission reduction and achieving sustainable development goals.
Open AccessApplication of Dynamic Weight Mixture Model Based on Dual Sliding Windows in Carbon Price Forecasting
As global climate change intensifies, nations around the world are implementing policies aimed at reducing emissions, with carbon-trading mechanisms emerging as a key market-based tool. China has launched carbon-trading markets in several cities, achieving significant trading volumes. Carbon-trading mechanisms encompass cap-and-trade markets and voluntary markets, influenced by various factors, including policy changes, economic conditions, energy prices, and climate fluctuations. The complexity of these factors, coupled with the nonlinear and non-stationary nature of carbon prices, makes forecasting a substantial challenge. This paper proposes a dynamic weight hybrid forecasting model based on a dual sliding window approach, effectively integrating multiple forecasting models such as LSTM, Random Forests, and LASSO. This model facilitates a thorough analysis of the influences of policy, market dynamics, technological advancements, and climatic conditions on carbon pricing. It serves as a potent tool for predicting carbon market price fluctuations and offers valuable decision support to stakeholders in the carbon market, ultimately aiding in the global efforts towards emission reduction and achieving sustainable development goals.
- Open Access
Study on the Operation Optimization of Medium-Depth U-Type Ground Source Heat Pump Systems
Deep geothermal energy is a sustainable and renewable spacing heating source. Although many studies have discussed the design optimization of deep borehole systems, few have accomplished optimization and in-depth analysis of system operation control. In this study, an analytical model of the U-type deep borehole heat exchanger is proposed, and the average relative error between the simulated outlet temperatures and experimental data is −3.2%. Then, this paper presents an integrated model for the operation optimization study of the U-type deep-borehole ground source heat pump system. The optimal control of flow rate is adopted to match the variation in heating load. Compared with the constant-flow rate (110 m3/h) operation mode, the variable flow rate method reduces the power consumption of the heat pump and circulating pump by 22.1%, from 288,423 kW·h to 224,592 kW·h, during 2112 h of operation. In addition, the system has a larger RHS and COP when the thermal conductivity of the backfill material increases. When the borehole depth increases by 200 m from 2300 m, the energy consumption of the circulating pump will drop from 85,844 kW·h to 56,548 kW·h. The COP of the heat pump unit will decrease approximately linearly as the heating load increases, and the total power consumption will increase accordingly. This work can provide guidance for the design and optimization of U-shaped GSHP systems.
Open AccessStudy on the Operation Optimization of Medium-Depth U-Type Ground Source Heat Pump Systems
Deep geothermal energy is a sustainable and renewable spacing heating source. Although many studies have discussed the design optimization of deep borehole systems, few have accomplished optimization and in-depth analysis of system operation control. In this study, an analytical model of the U-type deep borehole heat exchanger is proposed, and the average relative error between the simulated outlet temperatures and experimental data is −3.2%. Then, this paper presents an integrated model for the operation optimization study of the U-type deep-borehole ground source heat pump system. The optimal control of flow rate is adopted to match the variation in heating load. Compared with the constant-flow rate (110 m3/h) operation mode, the variable flow rate method reduces the power consumption of the heat pump and circulating pump by 22.1%, from 288,423 kW·h to 224,592 kW·h, during 2112 h of operation. In addition, the system has a larger RHS and COP when the thermal conductivity of the backfill material increases. When the borehole depth increases by 200 m from 2300 m, the energy consumption of the circulating pump will drop from 85,844 kW·h to 56,548 kW·h. The COP of the heat pump unit will decrease approximately linearly as the heating load increases, and the total power consumption will increase accordingly. This work can provide guidance for the design and optimization of U-shaped GSHP systems.
- Open Access
Construction and Electrothermal Performance Evaluation of a Solar-Powered Emergency Shelter
Power outages and poor thermal conditions are common in emergency shelters. In light of this, a novel design for a solar-powered emergency shelter (SPES) with flexible photovoltaics is proposed and investigated in this paper. Firstly, the space and structure of SPES are designed based on ergonomic and easy open-and-close requirements. Then, considering the finishing strength of the building and the convenience and economy of the processing design, the construction of solid models using a 1:2 equal scale, and three double-top SPES were developed, in which internal roofs are canvas, polyethylene(PE), and polyvinyl chloride(PVC). Finally, measurements and ANSYS-Fluent simulations are employed for testing the dynamic fluctuation of the electrothermal performance of SPES. It is found that the maximum differences between the inner roof interior side temperature (IRIST) and the outdoor ambient environment temperature (OAET) for Sref, Dsc, Dpe, and Dpvc are 33.3 °C, 32.9 °C, 28.1 °C, and 25.9 °C, respectively, in winter conditions in China cold zone. The optimized design parameters of SPES in Poso City, Indonesia, characterized by equatorial humid climatic conditions, recommended that the air interlayer be 0.2 meters thick and the exhaust air volume be 0.3 m3/s. Mechanical ventilation coupled with evaporative conditioners can further reduce indoor temperatures effectively. This research offers a novel solution to the problems of indoor thermal environments and power outages for post-disaster resettlement.
Open AccessConstruction and Electrothermal Performance Evaluation of a Solar-Powered Emergency Shelter
Power outages and poor thermal conditions are common in emergency shelters. In light of this, a novel design for a solar-powered emergency shelter (SPES) with flexible photovoltaics is proposed and investigated in this paper. Firstly, the space and structure of SPES are designed based on ergonomic and easy open-and-close requirements. Then, considering the finishing strength of the building and the convenience and economy of the processing design, the construction of solid models using a 1:2 equal scale, and three double-top SPES were developed, in which internal roofs are canvas, polyethylene(PE), and polyvinyl chloride(PVC). Finally, measurements and ANSYS-Fluent simulations are employed for testing the dynamic fluctuation of the electrothermal performance of SPES. It is found that the maximum differences between the inner roof interior side temperature (IRIST) and the outdoor ambient environment temperature (OAET) for Sref, Dsc, Dpe, and Dpvc are 33.3 °C, 32.9 °C, 28.1 °C, and 25.9 °C, respectively, in winter conditions in China cold zone. The optimized design parameters of SPES in Poso City, Indonesia, characterized by equatorial humid climatic conditions, recommended that the air interlayer be 0.2 meters thick and the exhaust air volume be 0.3 m3/s. Mechanical ventilation coupled with evaporative conditioners can further reduce indoor temperatures effectively. This research offers a novel solution to the problems of indoor thermal environments and power outages for post-disaster resettlement.