Oleksii Bodnaruk
Research Subjects
Oleksii Bodnaruk has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Alla Bosak
National Technical University of Ukraine Igor Sikorsky Kyiv Polytechnic Institute, 37, Beresteiskyi Ave., Kyiv, 03056, Ukraine
4 shared publications - Volodymyr Dubovyk
Igor Sikorsky KPI,Department of automation of electrotechnical and mechatronic complexes,Kyiv,Ukraine
2 shared publications - Anton Toropov
Національний технічний університет України «Київський політехнічний інститут імені Ігоря Сікорського
1 shared publication - Leonid Kulakovskyi
National Technical University of Ukraine “Igor Sikorsky Kyiv Polytechnic Institute
1 shared publication В. Г. Дубовик
1 shared publicationЛ. Я. Кулаковський
1 shared publication
Latest Publications
- Open Access
- 31 October 2025
- Published by Igor Sikorsky Kyiv Polytechnic Institute in POWER ENGINEERING: economics, technique, ecology
- No. 3
ENHANCING THE DYNAMIC STABILITY AND EFFICIENCY OF HYBRID PUMPING SYSTEMS THROUGH MPPT ALGORITHMS
The presented study analyzes the dynamic behavior of a hybrid power system designed to power critical loads, including pumping units. The system integrates a photovoltaic (PV) array, a battery energy storage system (BESS), and a connection to a centralized power grid. The focus is on assessing the robustness and efficiency of the energy management system under conditions of sharp changes in the level of solar insolation, simulating key operational scenarios: daytime generation, night mode (full shading), and hybrid operation with grid support. The methodology is based on dynamic modeling that reproduces the operation of the main system components. The results demonstrate exceptional stability of the DC bus voltage (within 620–640 V) in all operating modes. The system provides a seamless transition between power from the PV array and the BESS, confirming the key role of the battery as an effective energy buffer. Connection to the grid significantly increases the reliability of the system and allows them to accelerate the BESS charging process. The study confirms the viability and high operational reliability of the proposed hybrid topology for applications requiring guaranteed uninterrupted power supply.
- 31 October 2025
- Published by Igor Sikorsky Kyiv Polytechnic Institute in POWER ENGINEERING: economics, technique, ecology
- No. 3
Open AccessENHANCING THE DYNAMIC STABILITY AND EFFICIENCY OF HYBRID PUMPING SYSTEMS THROUGH MPPT ALGORITHMS
The presented study analyzes the dynamic behavior of a hybrid power system designed to power critical loads, including pumping units. The system integrates a photovoltaic (PV) array, a battery energy storage system (BESS), and a connection to a centralized power grid. The focus is on assessing the robustness and efficiency of the energy management system under conditions of sharp changes in the level of solar insolation, simulating key operational scenarios: daytime generation, night mode (full shading), and hybrid operation with grid support. The methodology is based on dynamic modeling that reproduces the operation of the main system components. The results demonstrate exceptional stability of the DC bus voltage (within 620–640 V) in all operating modes. The system provides a seamless transition between power from the PV array and the BESS, confirming the key role of the battery as an effective energy buffer. Connection to the grid significantly increases the reliability of the system and allows them to accelerate the BESS charging process. The study confirms the viability and high operational reliability of the proposed hybrid topology for applications requiring guaranteed uninterrupted power supply.
- Open Access
- 30 June 2025
- Published by Vidnovluvana energetika in Vidnovluvana energetika
- No. 2(81),p. 114-125
ГІБРИДНИЙ ПІДХІД ДО ВІДСТЕЖЕННЯ МАКСИМАЛЬНОЇ ТОЧКИ ПОТУЖНОСТІ У ФОТОЕЛЕКТРИЧНИХ СИСТЕМАХ
Стаття досліджує гібридний підхід до відстеження максимальної точки потужності (MPPT) у фотоелектричних системах, зосереджуючись на підвищенні ефективності та стабільності методів. Обговорюються різноманітні алгоритми MPPT, як-от Perturb and Observe (P&O), Incremental Conductance (INC) і Double Increment (DM), у поєднанні зі штучними нейронними мережами (ANN) та алгоритмом оптимізації рою частинок (PSO). Використання реальних даних сонячної електростанції дозволило провести комп’ютерне моделювання для оптимізації параметрів системи. Результати аналізу демонструють, що кожен метод має свої особливості, що дозволяє вибрати оптимальний підхід залежно від критеріїв, таких як продуктивність, стабільність та швидкість реакції. Отримані висновки можуть бути корисними для проєктування та налаштування PV-систем в умовах реальної експлуатації, особливо у змінних погодних умовах.
- 30 June 2025
- Published by Vidnovluvana energetika in Vidnovluvana energetika
- No. 2(81),p. 114-125
Open AccessГІБРИДНИЙ ПІДХІД ДО ВІДСТЕЖЕННЯ МАКСИМАЛЬНОЇ ТОЧКИ ПОТУЖНОСТІ У ФОТОЕЛЕКТРИЧНИХ СИСТЕМАХ
Стаття досліджує гібридний підхід до відстеження максимальної точки потужності (MPPT) у фотоелектричних системах, зосереджуючись на підвищенні ефективності та стабільності методів. Обговорюються різноманітні алгоритми MPPT, як-от Perturb and Observe (P&O), Incremental Conductance (INC) і Double Increment (DM), у поєднанні зі штучними нейронними мережами (ANN) та алгоритмом оптимізації рою частинок (PSO). Використання реальних даних сонячної електростанції дозволило провести комп’ютерне моделювання для оптимізації параметрів системи. Результати аналізу демонструють, що кожен метод має свої особливості, що дозволяє вибрати оптимальний підхід залежно від критеріїв, таких як продуктивність, стабільність та швидкість реакції. Отримані висновки можуть бути корисними для проєктування та налаштування PV-систем в умовах реальної експлуатації, особливо у змінних погодних умовах.
- Open Access
- 7 May 2025
- Published by National Academy of Sciences of Ukraine (Co. LTD Ukrinformnauka) (Publications) in System Research in Energy
- Vol. 2025 (2) , 77-90
COMPREHENSIVE ASSESSMENT OF THE USE OF PHOTOVOLTAIC STATIONS FOR POWERING PUMPS IN MULTI-STOREY BUILDINGS
In modern conditions, characterized by the destruction of critical infrastructure and instability of energy supply, ensuring a reliable water supply in multi-storey buildings is becoming especially relevant. This article is devoted to the study of the possibilities and problems of using photovoltaic power plants (PV) to power water supply pumps as an alternative energy source. The main goal of the study is to identify key factors that affect the efficiency and reliability of the PV power supply system for water supply pumps, as well as to develop recommendations for their optimization. The influence of weather conditions, in particular solar insolation and air temperature, on the performance of PV plants is analyzed in detail. Seasonal and daily fluctuations in insolation are considered, as well as their dependence on geographical location and atmospheric conditions. The influence of cloudiness, precipitation and fog on the intensity of solar radiation reaching the surface of PV panels is assessed. To analyze the efficiency of the system, a mathematical model has been developed that considers the dependence of the PV output power on solar insolation and panel temperature, the pump power on the required head and volume of water, as well as the operation of the maximum power point tracking (MPPT) algorithm and energy storage. The role of MPPT algorithms in increasing the efficiency of solar energy use is assessed. Ishikawa diagram is used to systematize key constraints. The developed mathematical model allows for a multiple assessment of the impact of various factors on system performance and the development of optimal control strategies. Keywords: photovoltaic station, pump power supply, renewable energy sources, optimization.
- 7 May 2025
- Published by National Academy of Sciences of Ukraine (Co. LTD Ukrinformnauka) (Publications) in System Research in Energy
- Vol. 2025 (2) , 77-90
Open AccessCOMPREHENSIVE ASSESSMENT OF THE USE OF PHOTOVOLTAIC STATIONS FOR POWERING PUMPS IN MULTI-STOREY BUILDINGS
In modern conditions, characterized by the destruction of critical infrastructure and instability of energy supply, ensuring a reliable water supply in multi-storey buildings is becoming especially relevant. This article is devoted to the study of the possibilities and problems of using photovoltaic power plants (PV) to power water supply pumps as an alternative energy source. The main goal of the study is to identify key factors that affect the efficiency and reliability of the PV power supply system for water supply pumps, as well as to develop recommendations for their optimization. The influence of weather conditions, in particular solar insolation and air temperature, on the performance of PV plants is analyzed in detail. Seasonal and daily fluctuations in insolation are considered, as well as their dependence on geographical location and atmospheric conditions. The influence of cloudiness, precipitation and fog on the intensity of solar radiation reaching the surface of PV panels is assessed. To analyze the efficiency of the system, a mathematical model has been developed that considers the dependence of the PV output power on solar insolation and panel temperature, the pump power on the required head and volume of water, as well as the operation of the maximum power point tracking (MPPT) algorithm and energy storage. The role of MPPT algorithms in increasing the efficiency of solar energy use is assessed. Ishikawa diagram is used to systematize key constraints. The developed mathematical model allows for a multiple assessment of the impact of various factors on system performance and the development of optimal control strategies. Keywords: photovoltaic station, pump power supply, renewable energy sources, optimization.
- Open Access
- 20 December 2023
- Published by National Technical University Kharkiv Polytechnic Institute in Bulletin of the National Technical University "KhPI". Series: Energy: Reliability and Energy Efficiency
- No. 2 (7),p. 9-15
Cascade control of electrical drives of a pumping station based on an astatic fuzzy regulator
The article discusses the main features of cascade pressure control in a water supply system with a controlled and additional uncontrolled pumps. The disadvantages of the existing control systems are formulated and it is proposed to control the pump station electric drives using correction of speed of the controlled pump depending on the mode of operation of the uncontrolled pump. A simplified mathematical model of the pressure control loop was developed, with the representation of the switching on of the additional pump as a disturbance effect of an aperiodic behavior. At the same time, the control algorithm of the additional pump is described in the form of unequivocal nonlinearities based on single step and signature functions, which allows to significantly simplify its implementation in the case of using microprocessor devices. To reduce the impact of disturbances in transient operating modes, namely when the additional pump is switched on, it is proposed to use the speed correction component for the main pump in the control algorithm. To avoid the formation of a static error, it is suggested to use a pressure regulator with integral component. Next, a refined mathematical model in the MATLAB environment was developed and an investigation of system operation using proportional-integral-derivative controller of pressure main pump speed control was carried out. It was determined that using of correction component allows to increase the accuracy of pressure control, but does not allow to compensate the presence of transport delay and nonlinearities of the system. Therefore, as a pressure regulator of the hydraulic system output, a combined astatic fuzzy regulator based on a proportional-integral control algorithm is used. The main difference of such a regulator is the automatic change of the gain factor when the error changes, which prevents the occurrence of unstable modes with large coefficients of the open system. The developed fuzzy control system provides a lot of benefits, such as increasing the reliability of the water supply network, improving the performance of the water supply system for consumers, reducing the wear and tear of pumping equipment, and reducing electricity consumption, which is confirmed by the results of numerical modeling. В статті розглянуті основні особливості каскадного керування тиском в системі водопостачання із регульованим і додатковим нерегульованим насосом. Сформульовані недоліки існуючих систем керування і запропоновано здійснювати керування електроприводами насосної станції із корекцією швидкості обертання регульованого насосу в залежності від режиму роботи нерегульованого. Розроблена спрощена математична модель контуру регулювання тиску із представленням вмикання додаткового насосу у вигляді збурюючого впливу аперіодичного характеру. При цьому закон керування додатковим насосом, описується у вигляді однозначних нелінійностей на основі одиничної ступінчастої і сигнатурної функцій, що дозволяє значно спростити його реалізацію у випадку використання мікропроцесорних пристроїв керування. Для зменшення впливу збурень в перехідних режимах роботи, а саме при вмиканні додаткового насосу, запропоновано використовувати в алгоритмі керування складову корекції швидкості для основного насосу. Для уникнення формування статичної похибки в роботі запропоновано використовувати регулятор тиску і інтегральною складовою. Далі розроблена уточнена математична модель в середовищі MATLAB і проведено дослідження роботи системи із пропорціонально-інтегрально-диференціальним регулятором тиску для регулювання швидкості основного насосу. Визначено, що використання складової корекції дозволяє підвищити точність регулювання тиску, однак не дозволяє скомпенсувати наявність транспортного запізнювання і нелінійностей системи. Тому, в якості регулятора тиску на виході гідравлічної системи використовується комбінований астатичний нечіткий регулятор на основі пропорційно-інтегрального алгоритму керування. Головна відмінність такого регулятора полягає у автоматичній зміні коефіцієнта підсилення при зміни помилки, що запобігає виникненню нестійких режимів при великих коефіцієнтах розімкнутої системи. Розроблена нечітка система керування дає низку переваг, таких як підвищення надійності...
- 20 December 2023
- Published by National Technical University Kharkiv Polytechnic Institute in Bulletin of the National Technical University "KhPI". Series: Energy: Reliability and Energy Efficiency
- No. 2 (7),p. 9-15
Open AccessCascade control of electrical drives of a pumping station based on an astatic fuzzy regulator
The article discusses the main features of cascade pressure control in a water supply system with a controlled and additional uncontrolled pumps. The disadvantages of the existing control systems are formulated and it is proposed to control the pump station electric drives using correction of speed of the controlled pump depending on the mode of operation of the uncontrolled pump. A simplified mathematical model of the pressure control loop was developed, with the representation of the switching on of the additional pump as a disturbance effect of an aperiodic behavior. At the same time, the control algorithm of the additional pump is described in the form of unequivocal nonlinearities based on single step and signature functions, which allows to significantly simplify its implementation in the case of using microprocessor devices. To reduce the impact of disturbances in transient operating modes, namely when the additional pump is switched on, it is proposed to use the speed correction component for the main pump in the control algorithm. To avoid the formation of a static error, it is suggested to use a pressure regulator with integral component. Next, a refined mathematical model in the MATLAB environment was developed and an investigation of system operation using proportional-integral-derivative controller of pressure main pump speed control was carried out. It was determined that using of correction component allows to increase the accuracy of pressure control, but does not allow to compensate the presence of transport delay and nonlinearities of the system. Therefore, as a pressure regulator of the hydraulic system output, a combined astatic fuzzy regulator based on a proportional-integral control algorithm is used. The main difference of such a regulator is the automatic change of the gain factor when the error changes, which prevents the occurrence of unstable modes with large coefficients of the open system. The developed fuzzy control system provides a lot of benefits, such as increasing the reliability of the water supply network, improving the performance of the water supply system for consumers, reducing the wear and tear of pumping equipment, and reducing electricity consumption, which is confirmed by the results of numerical modeling. В статті розглянуті основні особливості каскадного керування тиском в системі водопостачання із регульованим і додатковим нерегульованим насосом. Сформульовані недоліки існуючих систем керування і запропоновано здійснювати керування електроприводами насосної станції із корекцією швидкості обертання регульованого насосу в залежності від режиму роботи нерегульованого. Розроблена спрощена математична модель контуру регулювання тиску із представленням вмикання додаткового насосу у вигляді збурюючого впливу аперіодичного характеру. При цьому закон керування додатковим насосом, описується у вигляді однозначних нелінійностей на основі одиничної ступінчастої і сигнатурної функцій, що дозволяє значно спростити його реалізацію у випадку використання мікропроцесорних пристроїв керування. Для зменшення впливу збурень в перехідних режимах роботи, а саме при вмиканні додаткового насосу, запропоновано використовувати в алгоритмі керування складову корекції швидкості для основного насосу. Для уникнення формування статичної похибки в роботі запропоновано використовувати регулятор тиску і інтегральною складовою. Далі розроблена уточнена математична модель в середовищі MATLAB і проведено дослідження роботи системи із пропорціонально-інтегрально-диференціальним регулятором тиску для регулювання швидкості основного насосу. Визначено, що використання складової корекції дозволяє підвищити точність регулювання тиску, однак не дозволяє скомпенсувати наявність транспортного запізнювання і нелінійностей системи. Тому, в якості регулятора тиску на виході гідравлічної системи використовується комбінований астатичний нечіткий регулятор на основі пропорційно-інтегрального алгоритму керування. Головна відмінність такого регулятора полягає у автоматичній зміні коефіцієнта підсилення при зміни помилки, що запобігає виникненню нестійких режимів при великих коефіцієнтах розімкнутої системи. Розроблена нечітка система керування дає низку переваг, таких як підвищення надійності...