YGYifeng Gu

Yifeng Gu

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Yifeng Gu has a total of 27 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    A Comprehensive Characteristic Modeling Method for Francis Turbine Based on Image Digitization and RBF Neural Network

    by Youhan Deng, Youping Li, Xiaojun Hua, Rui Lyu, Yushu Li, Lei Wang, Weiwei Yao, Yifeng Gu, Fangqing Zhang, Jiang Guo

    Establishing a mathematical model of a Francis turbine is the foundation for the simulation of hydropower station operation and is of great significance for the analysis of the hydropower station’s transient process. Currently, in engineering practice, the model is often established based on the comprehensive characteristic curves of the Francis turbine provided by the manufacturer, using the external characteristic method. Traditional modeling methods mostly adopt manual reading of points or the use of dedicated numerical software for curve tracing to discretely sample the comprehensive characteristic curves of the turbine. This method is labor-intensive, inefficient, and relies on manual experience, with a small sample size, which, to some extent, affects the accuracy and reliability of the numerical processing results and cannot meet the needs of transient process simulation analysis. To address these shortcomings, this paper proposes a refined modeling method based on image numerical processing and an RBF neural network. Taking the HLA685 Francis turbine as an example, the method first uses image processing to achieve large-scale automated discrete sampling of the turbine’s high-efficiency zone characteristic data, then reasonably extends the small-opening and low-speed regions, and finally uses the RBF neural network method for interpolation and extrapolation to obtain the full characteristic data. This method can effectively improve the efficiency and accuracy of comprehensive characteristic modeling of the turbine and has good reference significance for the comprehensive characteristic modeling of blade-type machinery.


  • Open Access

    Research on Primary Frequency Regulation Control Strategy of the Joint Hydropower and Battery Energy Storage System Based on Refined Model

    by Yifeng Gu, Fangqing Zhang, Youping Li, Youhan Deng, Xiaojun Hua, Jiang Guo, Tingji Yang

    This study aims to reduce reverse power and improve frequency regulation performance in hydropower systems. To achieve this objective, a refined hydropower plant (HPP) simulation model is developed and coupled with a battery energy storage system (BESS), implementing an Integrated Adaptive Virtual Droop Control (IAVDC) strategy. The refined HPP model achieves a simulation accuracy of 98.5%, representing a 26.2% improvement over conventional simplified models. With the BESS integrated under the IAVDC strategy, reverse power is completely eliminated, and frequency regulation time is substantially shortened. The results demonstrate that the joint HPP-BESS frequency regulation effectively mitigates the adverse impact of water hammer, while the proposed IAVDC strategy enhances system responsiveness and reduces frequency recovery time, thereby improving the quality of primary frequency control.


  • Open Access

    Capacity Configuration Optimization of Wind–Light–Load Storage Based on Improved PSO

    by Benhong Wang, Ligui Wu, Peng Zhang, Yifeng Gu, Fangqing Zhang, Jiang Guo

    To improve the economy and stability of data center green power direct supply, the capacity configuration optimization of wind–light–load storage based on improved particle swarm optimization (PSO) is conducted. According to wind speed, the Weibull distribution of wind output is established, while the Beta distribution of solar output is established according to light intensity. Furthermore, by conducting the correlation analysis, it is indicated that there is a negative correlation between wind and solar output, which is helpful to optimize the mix of wind and solar output. To minimize the yearly average cost of wind–light–load storage, the capacity configuration optimization model is established, where the constraints include wind and solar output, energy storage capacity, balance between wind and solar output and data center load. To solve the capacity configuration optimization model, the improved PSO is adopted, compared to other optimization algorithms, like differential evolution (DE), genetic algorithm (GA) and grey wolf optimizer (GWO); by adjusting the inertia weight factor dynamically, the improved PSO is more likely to escape the local optimal solution. To validate the feasibility of data center green power direct supply with wind–light–load storage, a case study is conducted. By solving the capacity configuration optimization model of wind–light–load storage with the improved PSO, the balance rate between wind–solar output and data center load is improved by 12.5%, while the rate of abandoned wind and solar output is reduced by 17.5%, which is helpful to improve the economy and stability of data center green power direct supply.


  • Open Access

    Improved Droop Control Strategy for Islanded Microgrids Based on the Adaptive Weight Particle Swarm Optimization Algorithm

    by Binge Tu, Xianglian Xu, Yifeng Gu, Kaitian Deng, Yuli Xu, Tianyu Zhang, Xinrong Gao, Kangning Wang, Qingjie Wei

    In islanded low-voltage microgrids, the parallel operation of inverters using traditional droop control strategies often results in imbalanced output impedances among inverters due to variations in line impedance. This imbalance prevents the equitable distribution of reactive power according to the designated droop coefficients. To address this challenge, this paper proposes an improved droop control strategy. First, the virtual impedance control method is added to the strategy of traditional droop control, and then an adaptive weight particle swarm optimization algorithm (APSO) is introduced in the voltage outer loop control module to optimize the parameter setting of the PID controller. Finally, a comparative analysis was conducted on the output results of the improved droop control before and after introducing the algorithm. This proposed strategy is systematically analyzed through modeling and simulation in the MATLAB/Simulink environment to assess its impact on output voltage stability, reactive power sharing, and circulating current magnitude among parallel inverters. The simulation results indicate that the improved droop control with the introduction of virtual impedance effectively achieves equal reactive power sharing among parallel inverters. Moreover, by employing the APSO algorithm, the stability of the inverter output voltage is significantly enhanced. The maximum voltage deviation between two inverters is reduced to below 0.03%, while the maximum reactive power deviation decreases from over 3.5% to less than 2.5%. These improvements effectively reduce the circulating currents between two paralleled inverters, ensuring that the maximum current remains below 1.5 A and the minimum stays above −1 A.


  • Open Access

    Adaptive Weighted Particle Swarm Optimization for Controlling Multiple Switched Reluctance Motors with Enhanced Deviatoric Coupling Control

    by Tianyu Zhang, Xianglian Xu, Fangqing Zhang, Yifeng Gu, Kaitian Deng, Yuli Xu, Tunzhen Xie, Yuanqing Song

    Switched reluctance motors (SRMs) are widely used in industrial applications due to their advantages. Multi-motor synchronous control systems are crucial in modern industry, as their control strategies significantly impact synchronization performance. Traditional deviation coupling control structures face limitations during the startup phase, leading to excessive tracking errors and exacerbated by uneven load distribution, resulting in desynchronized motor acceleration and increased speed synchronization errors. This study proposes a modified deviation coupling control method based on an adaptive weighted particle swarm optimization (PSO) algorithm to enhance multi-motor synchronization performance. Traditional deviation coupling control applies equal reference torque inputs to each motor’s current loop, failing to address uneven load distribution and causing inconsistent accelerations. To resolve this, a gain equation based on speed deviation is introduced, incorporating self-tracking error and gain coefficients for dynamic synchronization error compensation. The gain coefficients are optimized using the adaptive weighted PSO algorithm to improve system adaptability. A simulation model of a synchronization control system for three SRMs was developed in the Matlab/Simulink R2023b environment. This model compares the synchronization performance of traditional deviation coupling, Fuzzy-PID improved structure, and adaptive PSO improved structure during motor startup, sudden speed increases, and load disturbances. The validated deviation coupling control structure achieved the initial set speed in approximately 0.236 s, demonstrating faster convergence and a 6.35% reduction in settling time. In both the motor startup and sudden speed increase phases, the two optimized methods outperformed the traditional structure in dynamic performance and synchronization accuracy, with the adaptive PSO structure improving synchronization accuracy by 54% and 37.17% over the Fuzzy-PID structure, respectively. Therefore, the PSO-optimized control system demonstrates faster convergence, improved stability, and enhanced synchronization performance.


  • Open Access

    Enhancement Methods of Hydropower Unit Monitoring Data Quality Based on the Hierarchical Density-Based Spatial Clustering of Applications with a Noise–Wasserstein Slim Generative Adversarial Imputation Network with a Gradient Penalty

    by Fangqing Zhang, Jiang Guo, Fang Yuan, Yuanfeng Qiu, Pei Wang, Fangjuan Cheng, Yifeng Gu

    In order to solve low-quality problems such as data anomalies and missing data in the condition monitoring data of hydropower units, this paper proposes a monitoring data quality enhancement method based on HDBSCAN-WSGAIN-GP, which improves the quality and usability of the condition monitoring data of hydropower units by combining the advantages of density clustering and a generative adversarial network. First, the monitoring data are grouped according to the density level by the HDBSCAN clustering method in combination with the working conditions, and the anomalies in this dataset are detected, recognized adaptively and cleaned. Further combining the superiority of the WSGAIN-GP model in data filling, the missing values in the cleaned data are automatically generated by the unsupervised learning of the features and the distribution of real monitoring data. The validation analysis is carried out by the online monitoring dataset of the actual operating units, and the comparison experiments show that the clustering contour coefficient (SCI) of the HDBSCAN-based anomaly detection model reaches 0.4935, which is higher than that of the other comparative models, indicating that the proposed model has superiority in distinguishing between the valid samples and anomalous samples. The probability density distribution of the data filling model based on WSGAIN-GP is similar to that of the measured data, and the KL dispersion, JS dispersion and Hellinger’s distance of the distribution between the filled data and the original data are close to 0. Compared with the filling methods such as SGAIN, GAIN, KNN, etc., the effect of data filling with different missing rates is verified, and the RMSE error of data filling with WSGAIN-GP is lower than that of other comparative models. The WSGAIN-GP method has the lowest RMSE error under different missing rates, which proves that the proposed filling model has good accuracy and generalization, and the research results in this paper provide a high-quality data basis for the subsequent trend prediction and state warning.