CCChengqun Chu

Chengqun Chu

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Chengqun Chu has a total of 20 co-authors. Here are the top co-authors by number of shared publications:

  • Ruirui Li

    State Key Laboratory of Extreme Environment Optoelectronic Dynamic Measurement Technology and Instrument, North University of China, Taiyuan 030051, China

    2 shared publications
  • Bingrui Zhang

    The Key Laboratory of Instrumentation Science & Dynamic Measurement Ministry of Education, North University of China, Taiyuan 030051, China

    1 shared publication
  • Bowen Qi

    The Key Laboratory of Instrumentation Science & Dynamic Measurement Ministry of Education, North University of China, Taiyuan 030051, China

    1 shared publication
  • Chenyang Xue

    North University of China

    1 shared publication
  • Guoyong Zhen

    State Key Laboratory of Dynamic Testing Technology, Jointly Established by the Province and the Ministry, North University of China, Taiyuan 030051, China

    1 shared publication
  • Haoran Li

    State Key Laboratory of Dynamic Testing Technology, Jointly Established by the Province and the Ministry, North University of China, Taiyuan 030051, China

    1 shared publication

Latest Publications

  • Open Access

    Flexible, Stretchable, and Self-Healing MXene-Based Conductive Hydrogels for Human Health Monitoring

    by Ruirui Li, Sijia Chang, Jiaheng Bi, Haotian Guo, Jianya Yi, Chengqun Chu

    Conductive hydrogels (CHs) have attracted significant attention in the fields of flexible electronics, human–machine interaction, and electronic skin (e-skin) due to their self-adhesiveness, environmental stability, and multi-stimuli responsiveness. However, integrating these diverse functionalities into a single conductive hydrogel system remains a challenge. In this study, polyvinyl alcohol (PVA) and polyacrylamide (PAM) were used as the dual-network matrix, lithium chloride and MXene were added, and a simple immersion strategy was adopted to synthesize a multifunctional MXene-based conductive hydrogel in a glycerol/water (1:1) binary solvent system. A subsequent investigation was then conducted on the hydrogel. The prepared PVA/PAM/LiCl/MXene hydrogel exhibits excellent tensile properties (~1700%), high electrical conductivity (1.6 S/m), and good self-healing ability. Furthermore, it possesses multimodal sensing performance, including humidity sensitivity (sensitivity of −1.09/% RH), temperature responsiveness (heating sensitivity of 2.2 and cooling sensitivity of 1.5), and fast pressure response/recovery times (220 ms/230 ms). In addition, the hydrogel has successfully achieved real-time monitoring of human joint movements (elbow and knee bending) and physiological signals (pulse, breathing), as well as enabled monitoring of spatial pressure distribution via a 3 × 3 sensor array. The performance and versatility of this hydrogel make it a promising candidate for next-generation flexible sensors, which can be applied in the fields of human health monitoring, electronic skin, and human–machine interaction.


  • Open Access

    Preparation of Infrared Anti-Reflection Surfaces Based on Microcone Structures of Silicon Carbide

    by Ruirui Li, Xiaozheng Ji, Sijia Chang, Haoyu Tian, Zihong Zhao, Chengqun Chu

    Silicon carbide (SiC) has become the material of choice for precision optical systems due to its exceptional optical characteristics. However, conventional anti-reflection strategies for SiC components predominantly utilize deposited thin-film coatings, which are frequently compromised by insufficient environmental robustness and long-term stability concerns. To overcome these limitations, direct nanostructuring of SiC substrates has emerged as a promising alternative solution. This work introduces an innovative graded-index microcone array design fabricated on SiC substrates, achieving superior broadband anti-reflection performance. Our two-step fabrication methodology comprises plasma-induced formation of tunable nanofiber etch masks through controlled argon bombardment parameters, followed by precision reactive ion etching (RIE) for microcone array formation. By systematically varying plasma exposure duration, we demonstrate precise control over nanofiber mask morphology, which in turn enables the fabrication of height-optimized SiC microcone arrays. The resulting structures exhibit exceptional optical performance, achieving an ultra-low average reflectivity of 2.25% across the spectral range of 2.5–8 μm. This breakthrough fabrication technique not only extends the available toolbox for SiC micro/nanofabrication but also provides a robust platform for next-generation optical applications. Unlike conventional thin-film approaches, our nanostructuring method preserves the intrinsic mechanical and environmental durability of the SiC substrate while delivering a favorable optical performance.


  • Open Access

    Noise-Perception Multi-Frame Collaborative Network for Enhanced Polyp Detection in Endoscopic Videos

    by Haoran Li, Guoyong Zhen, Chengqun Chu, Yuting Ma, Yongnan Zhao

    The accurate detection and localization of polyps during endoscopic examinations are critical for early disease diagnosis and cancer prevention. However, the presence of artifacts and noise, along with the high similarity between polyps and surrounding tissues in color, shape, and texture complicates polyp detection in video frames. To tackle these challenges, we deployed multivariate regression analysis to refine the model and introduced a Noise-Suppressing Perception Network (NSPNet) designed for enhanced performance. NSPNet leverages wavelet transform to enhance the model’s resistance to noise and artifacts while improving a multi-frame collaborative detection strategy for dynamic polyp detection in endoscopic videos, efficiently utilizing temporal information to strengthen features across frames. Specifically, we designed a High-Low Frequency Feature Fusion (HFLF) framework, which allows the model to capture high-frequency details more effectively. Additionally, we introduced an improved STFT-LSTM Polyp Detection (SLPD) module that utilizes temporal information from video sequences to enhance feature fusion in dynamic environments. Lastly, we integrated an Image Augmentation Polyp Detection (IAPD) module to improve performance on unseen data through preprocessing enhancement strategies. Extensive experiments demonstrate that NSPNet outperforms nine SOTA methods across four datasets on key performance metrics, including F1Score and recall.


  • Open Access

    Optimized Design of an Ultrasonic-Based High-Efficiency Wireless Passive Monitoring System for Sealed Metal Compartments

    by Bowen Qi, Juan Cui, Yongqiu Zheng, Bingrui Zhang, Chengqun Chu, Xiaolong Yan, Xiang Gao, Chenyang Xue

    The condition monitoring (CM) of sealed metal compartments (SMCs) is an urgently required restructure. Ultrasound penetrates SMCs to power and communicate with built-in sensors, enabling the CM of SMCs. However, current ultrasonic wireless power transfer and data communication (UWPTADC) systems are large and complex, and limited by the efficiency of energy transfer and data reliability. In this paper, an optimized design of a high-efficiency wireless passive monitoring system using UWPTADC techniques is proposed for SMC. The circuit model of the system is developed and analyzed to achieve an optimal design for efficient wireless power transfer and effective data communication coupling. A test system was constructed using a steel wall of 11 mm thickness as a validation object. At the ultrasonic carrier frequency of 1.045 MHz, the system has an energy transfer efficiency of 60%, and a communication rate of 50 kbps. In addition, the system realizes temperature and humidity monitoring inside a 13 mm thick cylindrical SMC, simulating the process of ultrasonic CM of an actual engine compartment. The system provides a wiring-free and battery-free solution for CM in SMCs, advancing CM in aerospace, marine and other fields.