Menezla Fayssal
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Menezla Fayssal has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Mohammed Debbal
Electronic and Telecommunication Department,Université de ain Témouchent,Aïn Temouchent,Algeria; Electronic and Telecommunication Department,Laboratory of Electronics, Telecommunications, Innovation and Intelligence (LET2I), Ain Temouchent,Ain Temouchent,Algeria, Algeria
2 shared publications A. Zerroug
Sonatrach Oil & Gas Co, Algiers, Algeria
1 shared publication- Abdelkader Boutaleb
Laboratory of Instrumentation and Advanced Materials (LIMA), Department of Electrical Engineering, University Center Nour El Bachir of El Bayadh, El Bayadh, Algeria
1 shared publication B. M. Sofiane
Nour Bachir Univ Ctr BayadhEl Bayadh, Dept Technol & Sci, El Bayadh, Algeria
1 shared publicationM. R. Lahcene
Nour Bachir Univ Ctr BayadhEl Bayadh, Dept Technol & Sci, El Bayadh, Algeria
1 shared publication- Sadouki Bouamama Reda
University of Saida, Algeria , Electromagnetism, Photonics and Optronics Laboratory (LEPO) , Sidi Bel Abbés , Algeria
1 shared publication
Latest Publications
- 24 August 2026
- Published by Springer Nature in Optical and Quantum Electronics
- Vol. 58 (11) , 490
A chromatic dispersion-based photonic crystal fiber sensor for high-sensitivity albumin detection
- 24 August 2026
- Published by Springer Nature in Optical and Quantum Electronics
- Vol. 58 (11) , 490
A chromatic dispersion-based photonic crystal fiber sensor for high-sensitivity albumin detection
- Open Access
- 1 December 2023
- Published by Scientia Publishing House in Acta Universitatis Sapientiae, Electrical and Mechanical Engineering
- Vol. 15 (1) , 33-44
Performance Analysis of Combining Beamforming and ZF/MMSE-SIC Equalization Techniques for MIMO DWPT-COFDM Systems
This study explores the enhancement of wireless communication through the integration of OFDM with MIMO and advanced techniques like COFDM, adaptive MIMO, and beamforming. It evaluates a 2×2 and 4×4 MIMO-DWPT-COFDM system, considering modulation (BPSK and QPSK) and equalization (ZF-SIC and MMSE-SIC) over a Rayleigh fading channel. MATLAB results reveal that more antennas, BPSK modulation, and MMSE-SIC equalization significantly improve BER performance. Specifically, for a BER of 10−4, the 2×2 MIMO system requiresEb/N0values of 10.4 (MMSE-SIC) and 11.4 (ZF-SIC), while the 4×4 MIMO system needs 5.5 (MMSE-SIC) and 5.9 (ZF-SIC). These findings emphasize the need for thoughtful system design and parameter optimization in achieving reliable and efficient wireless communication.
- 1 December 2023
- Published by Scientia Publishing House in Acta Universitatis Sapientiae, Electrical and Mechanical Engineering
- Vol. 15 (1) , 33-44
Open AccessPerformance Analysis of Combining Beamforming and ZF/MMSE-SIC Equalization Techniques for MIMO DWPT-COFDM Systems
This study explores the enhancement of wireless communication through the integration of OFDM with MIMO and advanced techniques like COFDM, adaptive MIMO, and beamforming. It evaluates a 2×2 and 4×4 MIMO-DWPT-COFDM system, considering modulation (BPSK and QPSK) and equalization (ZF-SIC and MMSE-SIC) over a Rayleigh fading channel. MATLAB results reveal that more antennas, BPSK modulation, and MMSE-SIC equalization significantly improve BER performance. Specifically, for a BER of 10−4, the 2×2 MIMO system requiresEb/N0values of 10.4 (MMSE-SIC) and 11.4 (ZF-SIC), while the 4×4 MIMO system needs 5.5 (MMSE-SIC) and 5.9 (ZF-SIC). These findings emphasize the need for thoughtful system design and parameter optimization in achieving reliable and efficient wireless communication.
- Open Access
- 11 April 2021
- Published by Engineering, Technology & Applied Science Research in Engineering, Technology & Applied Science Research
- Vol. 11 (2) , 6965-6569
Performance Improvement for Medical Image Transmission Systems using Turbo-Trellis Coded Modulation (TTCM)
Digital images have become an essential working tool in several areas such as the medical field, the satellite and astronomical field, film production, etc. The efficiency of a transmission system to exchange digital images is crucial to allow better and accurate reception. Generally, transmitted images are infected with noise. In the medical field, this noise makes the process of diagnosing difficult. To eliminate the transmission errors, an Error Correcting Code (ECC) can be used with the aim to guarantee excellent reception of the images and allowing a good diagnosis. In this paper, source and channel encoding/ decoding functions are studied during medical image transmission (LUNG). At first, the Turbo-Code (TC) is used as ECC and subsequently the Turbo-Trellis Coded Modulation (TTCM). The simulation results represent the curves giving the Bit Error Rate (BER) as a function of the signal to noise ratio (Eb/N0). In order to compare these two systems properly, the MSSIM (Mean Structural Similarity) parameter was used. The obtained results showed the effect and importance of ECC on the transmission of medical images using TTCM which gave better results compared to TC with regard to increasing the performance of the transmission system by eliminating transmission noise.
- 11 April 2021
- Published by Engineering, Technology & Applied Science Research in Engineering, Technology & Applied Science Research
- Vol. 11 (2) , 6965-6569
Open AccessPerformance Improvement for Medical Image Transmission Systems using Turbo-Trellis Coded Modulation (TTCM)
Digital images have become an essential working tool in several areas such as the medical field, the satellite and astronomical field, film production, etc. The efficiency of a transmission system to exchange digital images is crucial to allow better and accurate reception. Generally, transmitted images are infected with noise. In the medical field, this noise makes the process of diagnosing difficult. To eliminate the transmission errors, an Error Correcting Code (ECC) can be used with the aim to guarantee excellent reception of the images and allowing a good diagnosis. In this paper, source and channel encoding/ decoding functions are studied during medical image transmission (LUNG). At first, the Turbo-Code (TC) is used as ECC and subsequently the Turbo-Trellis Coded Modulation (TTCM). The simulation results represent the curves giving the Bit Error Rate (BER) as a function of the signal to noise ratio (Eb/N0). In order to compare these two systems properly, the MSSIM (Mean Structural Similarity) parameter was used. The obtained results showed the effect and importance of ECC on the transmission of medical images using TTCM which gave better results compared to TC with regard to increasing the performance of the transmission system by eliminating transmission noise.