Dursun Eşitmez
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Dursun Eşitmez has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Mustafa Çağlar
Istanbul Medipol Üniversitesi
3 shared publications - Mehmet Sıddık Cebe
Program of Radiotherapy Vocational School İstanbul Medipol University İstanbul Turkey
2 shared publications - Ayse Okumus
Department of Radiation Oncology, Yeni Yuzyil University Gaziosmanpasa Hospital, Istanbul, Turkey
1 shared publication Dilek Ünal
Department of Radiation Oncology School of Medicine İstanbul Medipol University İstanbul Turkey
1 shared publicationEsra Serin
Department of Health Physics Graduate School of Health Sciences İstanbul Medipol University İstanbul Turkey
1 shared publication- Evrim Metcalfe
Department of Radiation Oncology Bahçelievler Medipol Hospital İstanbul Turkey
1 shared publication
Latest Publications
- Open Access
- 30 March 2026
- Published by Canakkale Onsekiz Mart University in Journal of Advanced Research in Natural and Applied Sciences
- Vol. 12 (1) , 30-44
Comparative Assessment of Silver and Gold Nanoparticles for Dose Enhancement in Layered Skin Geometries: A Monte Carlo Sensitivity Study
This study quantifies nanoparticle-mediated dose modification in an idealized layered skin geometry using Monte Carlo (MCNP 6.3) (skin surface, epidermis ≈100 μm, dermis ≈500 μm, underlying skin). Homogeneous silver nanoparticles (AgNPs) and gold nanoparticles (AuNPs) at 5–30 mg/g were embedded in a 1 × 1 × 1 cm³ target, and energy-deposition tallies were converted to absorbed dose and reported as dose-enhancement factors (DEFs) normalized to 0 mg/g. Electron beams (6–12 Mega Electron Volt (MeV)) produced a near-linear DEF–concentration trend in the target with modest superficial gains; in contrast, low-energy photons (50/100 Kilo Electron Volt (keV)) yielded substantially higher enhancement, with AgNPs at 50 keV reaching ~560%, while adjacent normal-tissue sampling regions (OAR1–OAR6) remained near unity with mild, orientation-dependent anisotropy. Skin-layer summaries confirmed surface-weighted increases at low energies and more uniform depth profiles at higher MeV. Statistical uncertainties were
- 30 March 2026
- Published by Canakkale Onsekiz Mart University in Journal of Advanced Research in Natural and Applied Sciences
- Vol. 12 (1) , 30-44
Open AccessComparative Assessment of Silver and Gold Nanoparticles for Dose Enhancement in Layered Skin Geometries: A Monte Carlo Sensitivity Study
This study quantifies nanoparticle-mediated dose modification in an idealized layered skin geometry using Monte Carlo (MCNP 6.3) (skin surface, epidermis ≈100 μm, dermis ≈500 μm, underlying skin). Homogeneous silver nanoparticles (AgNPs) and gold nanoparticles (AuNPs) at 5–30 mg/g were embedded in a 1 × 1 × 1 cm³ target, and energy-deposition tallies were converted to absorbed dose and reported as dose-enhancement factors (DEFs) normalized to 0 mg/g. Electron beams (6–12 Mega Electron Volt (MeV)) produced a near-linear DEF–concentration trend in the target with modest superficial gains; in contrast, low-energy photons (50/100 Kilo Electron Volt (keV)) yielded substantially higher enhancement, with AgNPs at 50 keV reaching ~560%, while adjacent normal-tissue sampling regions (OAR1–OAR6) remained near unity with mild, orientation-dependent anisotropy. Skin-layer summaries confirmed surface-weighted increases at low energies and more uniform depth profiles at higher MeV. Statistical uncertainties were
- Open Access
- 3 April 2025
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 26 (6) , e70085
Surface dose analysis and dosimetric comparison of Halcyon versus Truebeam in breast cancer radiotherapy: An OSL dosimetry study
Purpose: Breast cancer is a neoplastic disease with high prevalence among women. Radiotherapy is one of the principal treatment modalities for this disease, but it poses significant challenges. This study aimed to compare and evaluate the technical and dosimetric performance of conventional C‐arm linac systems and a new design, Halcyon, in the context of breast radiotherapy.Methods: The study included ten patients who had undergone left breast radiotherapy. Additionally, breast radiotherapy was simulated with an anthropomorphic phantom, and similar planning studies were performed. A total of 40 treatment plans were prepared for ten patients using the field‐in‐field (FinF) and volumetric modulated arc therapy (VMAT) techniques on both TrueBeam and Halcyon systems. Subsequently, treatment plans were created for anthropomorphic phantoms using both techniques on both devices. The dosimetric comparisons were conducted on treatment plans with different treatment techniques on both devices. An anthropomorphic phantom was employed to ascertain the surface dose during treatment, with irradiation conducted in the following with the OSL dosimetry method.Results: Patient plan comparisons showed no statistically significant differences in planning target volume (PTV) outcomes between techniques and devices. Upon analysis of the organ at risk (OAR), statistically significant differences were identified for FinF in both devices for low‐dose regions. Analysis of the OSL results obtained from phantom irradiations revealed that the Halcyon results were higher than those obtained with the TrueBeam for both techniques. Additionally, a comparison of OSL results with the TPS data revealed discrepancies of up to 18% within the field and up to 22% outside the field. Furthermore, Halcyon demonstrated higher Monitor Unit (MU) values for both techniques, while still maintaining shorter treatment times.Conclusion: The Halcyon demonstrated comparable technical and dosimetric outcomes to conventional C‐arm linac in breast radiotherapy. Its distinctive design features contribute to the implementation of efficient and secure treatment modalities.
- 3 April 2025
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 26 (6) , e70085
Open AccessSurface dose analysis and dosimetric comparison of Halcyon versus Truebeam in breast cancer radiotherapy: An OSL dosimetry study
Purpose: Breast cancer is a neoplastic disease with high prevalence among women. Radiotherapy is one of the principal treatment modalities for this disease, but it poses significant challenges. This study aimed to compare and evaluate the technical and dosimetric performance of conventional C‐arm linac systems and a new design, Halcyon, in the context of breast radiotherapy.Methods: The study included ten patients who had undergone left breast radiotherapy. Additionally, breast radiotherapy was simulated with an anthropomorphic phantom, and similar planning studies were performed. A total of 40 treatment plans were prepared for ten patients using the field‐in‐field (FinF) and volumetric modulated arc therapy (VMAT) techniques on both TrueBeam and Halcyon systems. Subsequently, treatment plans were created for anthropomorphic phantoms using both techniques on both devices. The dosimetric comparisons were conducted on treatment plans with different treatment techniques on both devices. An anthropomorphic phantom was employed to ascertain the surface dose during treatment, with irradiation conducted in the following with the OSL dosimetry method.Results: Patient plan comparisons showed no statistically significant differences in planning target volume (PTV) outcomes between techniques and devices. Upon analysis of the organ at risk (OAR), statistically significant differences were identified for FinF in both devices for low‐dose regions. Analysis of the OSL results obtained from phantom irradiations revealed that the Halcyon results were higher than those obtained with the TrueBeam for both techniques. Additionally, a comparison of OSL results with the TPS data revealed discrepancies of up to 18% within the field and up to 22% outside the field. Furthermore, Halcyon demonstrated higher Monitor Unit (MU) values for both techniques, while still maintaining shorter treatment times.Conclusion: The Halcyon demonstrated comparable technical and dosimetric outcomes to conventional C‐arm linac in breast radiotherapy. Its distinctive design features contribute to the implementation of efficient and secure treatment modalities.
- Open Access
- 1 January 2024
- Published by SAGE Publications in Technology in Cancer Research & Treatment
- Vol. 23
The Effect of Dose Enhancement in Tumor With Silver Nanoparticles on Surrounding Healthy Tissues: A Monte Carlo Study
Objectives: Cancer-related death rates account for approximately one-third of all deaths, and this rate is increasing remarkably every year. In this study, we examined the dose enhancement factor (DEF) in the tumor and surrounding tissues by adding different concentrations of silver nanoparticles (AgNPs) to the brain tumor using the Monte Carlo (MC) technique. Methods: This study used MCNP6.2 simulation software. A Planning Target Volume (PTV) of 1 × 1 × 1 cm3 was placed in the center of a cubic cranial model with dimensions of 5 × 5 × 5 cm3. Five different simulations were initially generated using the simple method. These simulations included pure PTV and PTV consisting of 4 different silver concentrations (5, 10, 20, and 30 mg/g). Additionally, a model was created using the nanolattice method, considering the size, position, and distribution of the AgNPs. Irradiation was performed using a source with a 6 MV linac photon spectrum. Measurements were performed using the *f8 tally, and DEF values were calculated. Results: In the simulation study using the simple method, the DEF value of PTV increased linearly with concentration, whereas the DEF values were lower than the simulation results with the nanolattice model (1.9 vs 1.4 for 30 mg/g NP concentration). Performing the simple method, we observed no remarkable dose increase in lateral OARs surrounding PTV. While a remarkable dose decrease was observed in distal OARs, a dose increase in the proximal OAR was observed, which was consistent with that of PTV. However, according to the results obtained by performing the nanolattice method, the dose increase was observed in both the proximal OAR and the distal OAR and was similar to that of PTV. Conclusion: While enhancing the dose in the tumor by adding NPs into the tumor, it is essential to consider whether it also increases the OAR dose. In addition, simulation studies on NPs showed that the dose increase varied significantly with particle size, position, and distribution. Hence, these factors should be considered carefully.
- 1 January 2024
- Published by SAGE Publications in Technology in Cancer Research & Treatment
- Vol. 23
Open AccessThe Effect of Dose Enhancement in Tumor With Silver Nanoparticles on Surrounding Healthy Tissues: A Monte Carlo Study
Objectives: Cancer-related death rates account for approximately one-third of all deaths, and this rate is increasing remarkably every year. In this study, we examined the dose enhancement factor (DEF) in the tumor and surrounding tissues by adding different concentrations of silver nanoparticles (AgNPs) to the brain tumor using the Monte Carlo (MC) technique. Methods: This study used MCNP6.2 simulation software. A Planning Target Volume (PTV) of 1 × 1 × 1 cm3 was placed in the center of a cubic cranial model with dimensions of 5 × 5 × 5 cm3. Five different simulations were initially generated using the simple method. These simulations included pure PTV and PTV consisting of 4 different silver concentrations (5, 10, 20, and 30 mg/g). Additionally, a model was created using the nanolattice method, considering the size, position, and distribution of the AgNPs. Irradiation was performed using a source with a 6 MV linac photon spectrum. Measurements were performed using the *f8 tally, and DEF values were calculated. Results: In the simulation study using the simple method, the DEF value of PTV increased linearly with concentration, whereas the DEF values were lower than the simulation results with the nanolattice model (1.9 vs 1.4 for 30 mg/g NP concentration). Performing the simple method, we observed no remarkable dose increase in lateral OARs surrounding PTV. While a remarkable dose decrease was observed in distal OARs, a dose increase in the proximal OAR was observed, which was consistent with that of PTV. However, according to the results obtained by performing the nanolattice method, the dose increase was observed in both the proximal OAR and the distal OAR and was similar to that of PTV. Conclusion: While enhancing the dose in the tumor by adding NPs into the tumor, it is essential to consider whether it also increases the OAR dose. In addition, simulation studies on NPs showed that the dose increase varied significantly with particle size, position, and distribution. Hence, these factors should be considered carefully.
- Open Access
- 31 December 2023
- Published by Korean Society of Medical Physics in Progress in Medical Physics
- Vol. 34 (4) , 41-47
Dosimetric Comparison of Three-Dimensional Conformal, Intensity-Modulated Radiotherapy, Volumetric Modulated Arc Therapy, and Dynamic Conformal Arc Therapy Techniques in Prophylactic Cranial Irradiation
Ismail Faruk Durmuş, Dursun Esitmez, Guner Ipek Arslan, Ayse Okumus. Progress in Medical Physics 2023;34:41-7. https://doi.org/10.14316/pmp.2023.34.4.41
- 31 December 2023
- Published by Korean Society of Medical Physics in Progress in Medical Physics
- Vol. 34 (4) , 41-47
Open AccessDosimetric Comparison of Three-Dimensional Conformal, Intensity-Modulated Radiotherapy, Volumetric Modulated Arc Therapy, and Dynamic Conformal Arc Therapy Techniques in Prophylactic Cranial Irradiation
Ismail Faruk Durmuş, Dursun Esitmez, Guner Ipek Arslan, Ayse Okumus. Progress in Medical Physics 2023;34:41-7. https://doi.org/10.14316/pmp.2023.34.4.41