Hongliang Han
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Hongliang Han has a total of 51 co-authors. Here are the top co-authors by number of shared publications:
- Zhanfang Ma
Department of Chemistry, Capital Normal University, Beijing 100048, China
26 shared publications Jiejie Feng
Capital Normal Univ, Dept Chem, Beijing 100048, Peoples R China
5 shared publicationsTao Yao
Capital Normal Univ, Dept Chem, Beijing 100048, Peoples R China
5 shared publicationsZhanfang Ma
5 shared publicationsXianrui Jiang
Department of Chemistry, Capital Normal University, Beijing, 100048, China
4 shared publicationsZiwei Wang
Department of Chemistry, Capital Normal University, Beijing 100048, China
4 shared publications
Latest Publications
- 15 July 2026
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
Cascade-driven dual-signal attenuation antifouling immunosensor for femtogram-level sensing for SCCA
Nonspecific adsorption compromises the accuracy of electrochemical immunosensors in complex biological samples. Conventional antifouling materials often suffer from poor conductivity, which reduces sensitivity. To address this, a cascade-driven dual-signal attenuation strategy was designed. A hydrophilic conductive composite (GO/AuNPs/PPy/PA/MB, GAPPM) was synthesized via a one‑pot method to fabricate the sensing interface, and capture antibodies were anchored by electrodeposited AuNPs. The immunoprobe was constructed by combining GOx‑encapsulated ZIF‑8 with labeling antibodies linked via in‑situ grown AuNPs. Upon target antigen binding, a sandwich immunocomplex was formed on the electrode surface, and two cascade pathways were activated by glucose: (i) degradation of methylene blue signal molecules was induced, leading to attenuation of the current, and (ii) generation of an insoluble coordination precipitate was promoted, increasing interfacial resistance. Dual‑path cascade signal amplification was thus achieved synergistically. Using squamous cell carcinoma antigen as a model, the immunosensor achieved a detection limit of 29.5 fg mL⁻1 and a wide linear range (1 pg mL⁻1 to 1 µg mL⁻1). Notably, after 30-min incubation in undiluted human serum, the modified electrode exhibited an impedance change 56% lower than that of its BSA‑blocked counterpart, confirming excellent antifouling properties. This strategy holds great promise for high‑performance electrochemical biosensing in complex biological samples.
- 15 July 2026
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
Cascade-driven dual-signal attenuation antifouling immunosensor for femtogram-level sensing for SCCA
Nonspecific adsorption compromises the accuracy of electrochemical immunosensors in complex biological samples. Conventional antifouling materials often suffer from poor conductivity, which reduces sensitivity. To address this, a cascade-driven dual-signal attenuation strategy was designed. A hydrophilic conductive composite (GO/AuNPs/PPy/PA/MB, GAPPM) was synthesized via a one‑pot method to fabricate the sensing interface, and capture antibodies were anchored by electrodeposited AuNPs. The immunoprobe was constructed by combining GOx‑encapsulated ZIF‑8 with labeling antibodies linked via in‑situ grown AuNPs. Upon target antigen binding, a sandwich immunocomplex was formed on the electrode surface, and two cascade pathways were activated by glucose: (i) degradation of methylene blue signal molecules was induced, leading to attenuation of the current, and (ii) generation of an insoluble coordination precipitate was promoted, increasing interfacial resistance. Dual‑path cascade signal amplification was thus achieved synergistically. Using squamous cell carcinoma antigen as a model, the immunosensor achieved a detection limit of 29.5 fg mL⁻1 and a wide linear range (1 pg mL⁻1 to 1 µg mL⁻1). Notably, after 30-min incubation in undiluted human serum, the modified electrode exhibited an impedance change 56% lower than that of its BSA‑blocked counterpart, confirming excellent antifouling properties. This strategy holds great promise for high‑performance electrochemical biosensing in complex biological samples.
- 3 March 2026
- Published by Elsevier in Journal of Colloid and Interface Science
- Vol. 714, 140232
Small molecule recognition based on molecularly imprinted labels
- 3 March 2026
- Published by Elsevier in Journal of Colloid and Interface Science
- Vol. 714, 140232
Small molecule recognition based on molecularly imprinted labels
- 24 September 2025
- Published by Elsevier in Bioelectrochemistry
- Vol. 168, 109120
Highly water-retaining conductive hydrogels based on multi-crosslinked networks for ultrasensitive sensing platform
- 24 September 2025
- Published by Elsevier in Bioelectrochemistry
- Vol. 168, 109120
Highly water-retaining conductive hydrogels based on multi-crosslinked networks for ultrasensitive sensing platform
- 16 September 2025
- Published by Elsevier in Journal of Colloid and Interface Science
- Vol. 702 (Pt 2) , 139032
“AND” logic gate recognition interface for phospholipids based on fragment imprinting
- 16 September 2025
- Published by Elsevier in Journal of Colloid and Interface Science
- Vol. 702 (Pt 2) , 139032
“AND” logic gate recognition interface for phospholipids based on fragment imprinting
- 26 May 2025
- Published by Elsevier in Journal of Colloid and Interface Science
- Vol. 697, 137987
Imprinted probes achieve highly specific recognition of L-phenylalanine
- 26 May 2025
- Published by Elsevier in Journal of Colloid and Interface Science
- Vol. 697, 137987
Imprinted probes achieve highly specific recognition of L-phenylalanine