Cristina Obispo Díaz
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Cristina Obispo Díaz has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
- Alicia Celemín-Viñuela
Department of Prosthodontics, Faculty of Dentistry, University Complutense of Madrid, 28040 Madrid, Spain
1 shared publication Ana Boquete-Castro
Facultad de Odontología, Universidad Alfonso X el Sabio, Avenida de la Universidad 1, 28691 Villanueva de la Cañada, Spain
1 shared publication- Ari Braemer
Faculty of Dentistry Universidad Alfonso X el Sabio Madrid Spain
1 shared publication - Cristian Docampo-Vázquez
Facultad de Odontología, Universidad Alfonso X El Sabio, 28691 Madrid, Spain
1 shared publication - Cristina Rico-Romano
Faculty of Dentistry, Alfonso X El Sabio University, 28691 Madrid, Spain
1 shared publication - Enrique Pérez-Miguel
Universidad Diego Portales
1 shared publication
Latest Publications
- 11 October 2026
- Published by Wiley in Color Research & Application
- Vol. 51 (6) , e70134
Impact of Material Aging and Time‐Dependent Factors on the Color Stability of Dental Shade Guides: A Spectrophotometric Assessment
Background/Objectives: Dental shade guides are widely used for clinical color determination; however, their chromatic stability under routine clinical use remains uncertain. This study aimed to evaluate whether color changes occur in dental shade guide tabs subjected exclusively to normal clinical use, without accelerated disinfection or sterilization procedures. Materials and Methods: Color measurements were performed using a Vita Easyshade V spectrophotometer in Guide Check mode on complete Vita 3D‐Master shade guides, including one unused guide and six guides clinically used for more than 5 years. Each shade tab was measured three times under standardized conditions, and the categorical color parameters (value, hue, and chroma) were recorded according to the manufacturer's shade classification. Identification accuracy was defined as the percentage of exact agreement between the spectrophotometer output and the nominal shade tab designation. Color agreement was evaluated using descriptive analysis and Cohen's κ statistics. Results: The spectrophotometer demonstrated an overall identification accuracy of 82.4% (95% CI: 79.2–85.6) based on 546 total measurements. The new guide showed a color match rate of 89.3% ( κ = 0.853), whereas guides used for more than 5 years exhibited a significantly lower match rate of 51.1% ( κ = 0.489). Differences in agreement between new and used guides were statistically significant ( p < 0.001). Conclusions: The Vita Easyshade V spectrophotometer showed high reliability for shade identification. However, clinically used Vita 3D‐Master shade guides demonstrated substantial color degradation over time, which may compromise their reliability for clinical shade selection.
- 11 October 2026
- Published by Wiley in Color Research & Application
- Vol. 51 (6) , e70134
Impact of Material Aging and Time‐Dependent Factors on the Color Stability of Dental Shade Guides: A Spectrophotometric Assessment
Background/Objectives: Dental shade guides are widely used for clinical color determination; however, their chromatic stability under routine clinical use remains uncertain. This study aimed to evaluate whether color changes occur in dental shade guide tabs subjected exclusively to normal clinical use, without accelerated disinfection or sterilization procedures. Materials and Methods: Color measurements were performed using a Vita Easyshade V spectrophotometer in Guide Check mode on complete Vita 3D‐Master shade guides, including one unused guide and six guides clinically used for more than 5 years. Each shade tab was measured three times under standardized conditions, and the categorical color parameters (value, hue, and chroma) were recorded according to the manufacturer's shade classification. Identification accuracy was defined as the percentage of exact agreement between the spectrophotometer output and the nominal shade tab designation. Color agreement was evaluated using descriptive analysis and Cohen's κ statistics. Results: The spectrophotometer demonstrated an overall identification accuracy of 82.4% (95% CI: 79.2–85.6) based on 546 total measurements. The new guide showed a color match rate of 89.3% ( κ = 0.853), whereas guides used for more than 5 years exhibited a significantly lower match rate of 51.1% ( κ = 0.489). Differences in agreement between new and used guides were statistically significant ( p < 0.001). Conclusions: The Vita Easyshade V spectrophotometer showed high reliability for shade identification. However, clinically used Vita 3D‐Master shade guides demonstrated substantial color degradation over time, which may compromise their reliability for clinical shade selection.
- Open Access
- 2 April 2025
- Published by MDPI AG in Bioengineering
- Vol. 12 (4)
Randomised Clinical Trial: Effect of AH Plus and Neosealer Flo on Postoperative Pain and Healing of Periapical Lesions
Apical periodontitis is a common inflammatory condition associated with root canal treatment (RCT) failure. The quality of the three-dimensional root canal seal is critical to the success of the treatment. Bioceramic sealants, such as Neosealer Flo, offer biological advantages such as osteoconduction, biocompatibility and sustained calcium ion release, which may improve apical healing. The aim of this study was to compare AH Plus and Neosealer Flo in terms of postoperative pain, extrusion and periapical healing. A single-blind, randomised clinical trial was conducted with 60 patients divided into AH Plus and Neosealer Flo groups. Post-operative pain was assessed using a visual analogue scale (VAS) at 24 and 48 h and at 7 days. Seal quality and periapical healing were assessed at 6 months using the AAE success criteria by clinical and radiographic evaluation. Neosealer Flo resulted in less postoperative pain at 24 h and 7 days compared to AH Plus. Extrusion did not significantly affect pain or correlate with the type of sealer used. Both materials achieved similar periapical healing rates. Neosealer Flo demonstrated advantages in pain reduction, while both sealants showed comparable efficacy.
- 2 April 2025
- Published by MDPI AG in Bioengineering
- Vol. 12 (4)
Open AccessRandomised Clinical Trial: Effect of AH Plus and Neosealer Flo on Postoperative Pain and Healing of Periapical Lesions
Apical periodontitis is a common inflammatory condition associated with root canal treatment (RCT) failure. The quality of the three-dimensional root canal seal is critical to the success of the treatment. Bioceramic sealants, such as Neosealer Flo, offer biological advantages such as osteoconduction, biocompatibility and sustained calcium ion release, which may improve apical healing. The aim of this study was to compare AH Plus and Neosealer Flo in terms of postoperative pain, extrusion and periapical healing. A single-blind, randomised clinical trial was conducted with 60 patients divided into AH Plus and Neosealer Flo groups. Post-operative pain was assessed using a visual analogue scale (VAS) at 24 and 48 h and at 7 days. Seal quality and periapical healing were assessed at 6 months using the AAE success criteria by clinical and radiographic evaluation. Neosealer Flo resulted in less postoperative pain at 24 h and 7 days compared to AH Plus. Extrusion did not significantly affect pain or correlate with the type of sealer used. Both materials achieved similar periapical healing rates. Neosealer Flo demonstrated advantages in pain reduction, while both sealants showed comparable efficacy.
- Open Access
- 18 March 2024
- Published by Universidad Pontificia Comillas in Revista Iberoamericana de Bioética
- No. 24,p. 1-15
Hacia una cultura paliativa: nivel de conocimiento y creencias erróneas sobre cuidados paliativos, sedación paliativa y eutanasia
El presente estudio tuvo como objetivo analizar el nivel de conocimiento de los conceptos de cuidados paliativos, sedación paliativa y eutanasia, lo que podría influir en la toma de decisiones éticas relacionadas con final de vida. Para ello, se elaboró un cuestionario ad hoc administrado entre los asistentes a unas Jornadas de Cuidados Paliativos en la Comunidad de Madrid (n = 142). La T de Student mostró que existen diferencias significativas (p < 0.05) entre los tres pares de conceptos y se encontraron correlaciones entre el grado de conocimiento de los tres constructos. La experiencia laboral y el nivel de conocimientos en cuidados paliativos correlaciona con un mayor conocimiento sobre eutanasia y sedación paliativa, encontrando diferencias estadísticamente significativas por nivel de estudios. Estos resultados sugieren que fomentar el conocimiento de cuidados paliativos disminuirá la presencia de ideas erróneas en deliberaciones relacionadas con el final de la vida, sedación y eutanasia.
- 18 March 2024
- Published by Universidad Pontificia Comillas in Revista Iberoamericana de Bioética
- No. 24,p. 1-15
Open AccessHacia una cultura paliativa: nivel de conocimiento y creencias erróneas sobre cuidados paliativos, sedación paliativa y eutanasia
El presente estudio tuvo como objetivo analizar el nivel de conocimiento de los conceptos de cuidados paliativos, sedación paliativa y eutanasia, lo que podría influir en la toma de decisiones éticas relacionadas con final de vida. Para ello, se elaboró un cuestionario ad hoc administrado entre los asistentes a unas Jornadas de Cuidados Paliativos en la Comunidad de Madrid (n = 142). La T de Student mostró que existen diferencias significativas (p < 0.05) entre los tres pares de conceptos y se encontraron correlaciones entre el grado de conocimiento de los tres constructos. La experiencia laboral y el nivel de conocimientos en cuidados paliativos correlaciona con un mayor conocimiento sobre eutanasia y sedación paliativa, encontrando diferencias estadísticamente significativas por nivel de estudios. Estos resultados sugieren que fomentar el conocimiento de cuidados paliativos disminuirá la presencia de ideas erróneas en deliberaciones relacionadas con el final de la vida, sedación y eutanasia.
- Open Access
- 28 December 2023
- Published by MDPI AG in Journal of Personalized Medicine
- Vol. 14 (1) , 37
Influence of Augmented Reality Appliances on Tooth Preparation Designs—An In Vitro Study
The aim of this work was to analyze and compare the tooth structure removal between a free-hand preparation technique and a computer-aided preparation technique using an augmented reality appliance for complete-crowns preparation designs and “root mean square” (RMS) alignment value. Ten upper teeth representatives of all dental sectors were selected from a generic model library as “Standard Tessellation Language” (STL-1) digital files and 3D-printed in an anatomically based acrylic resin experimental model. Then these were randomly assigned to the following tooth preparation techniques: Group A: free-hand preparation technique (n = 5) (FHT) and Group B: computer-aided preparation technique using an augmented reality appliance (n = 5) (AR). Experimental models were submitted to a digital impression through an intraoral scan and (STL-2) uploaded into a reverse engineering morphometric software to measure the volumetric reduction in the planned and performed tooth structure (mm3) and RMS using the Student’s t-test and the Mann–Whitney non-parametric test. Statistically significant differences were observed between the volumetric reduction in the planned and performed tooth structure (mm3) of the AR and FHT study groups (p = 0.0001). Moreover, statistically significant differences were observed between the RMS of the planned and performed tooth preparations in both the AR and FHT study groups (p = 0.0005). The augmented reality appliance provides a more conservative and predictable complete-crowns preparation design than the free-hand preparation technique.
- 28 December 2023
- Published by MDPI AG in Journal of Personalized Medicine
- Vol. 14 (1) , 37
Open AccessInfluence of Augmented Reality Appliances on Tooth Preparation Designs—An In Vitro Study
The aim of this work was to analyze and compare the tooth structure removal between a free-hand preparation technique and a computer-aided preparation technique using an augmented reality appliance for complete-crowns preparation designs and “root mean square” (RMS) alignment value. Ten upper teeth representatives of all dental sectors were selected from a generic model library as “Standard Tessellation Language” (STL-1) digital files and 3D-printed in an anatomically based acrylic resin experimental model. Then these were randomly assigned to the following tooth preparation techniques: Group A: free-hand preparation technique (n = 5) (FHT) and Group B: computer-aided preparation technique using an augmented reality appliance (n = 5) (AR). Experimental models were submitted to a digital impression through an intraoral scan and (STL-2) uploaded into a reverse engineering morphometric software to measure the volumetric reduction in the planned and performed tooth structure (mm3) and RMS using the Student’s t-test and the Mann–Whitney non-parametric test. Statistically significant differences were observed between the volumetric reduction in the planned and performed tooth structure (mm3) of the AR and FHT study groups (p = 0.0001). Moreover, statistically significant differences were observed between the RMS of the planned and performed tooth preparations in both the AR and FHT study groups (p = 0.0005). The augmented reality appliance provides a more conservative and predictable complete-crowns preparation design than the free-hand preparation technique.