Zuzana Kadlecová
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Zuzana Kadlecová has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
- Lucy Vojtová
Advanced Biomaterials Group, Central European Institute of Technology, Brno University of Technology, Purkyňova 656/123, 612 00 Brno, Czech Republic
4 shared publications - David Rebenda
Department of Tribology, Faculty of Mechanical Engineering, Brno University of Technology, Technická 2896/2, 616 69 Brno, Czech Republic
2 shared publications Ivana Chamradová
Advanced Biomaterials, Central European Institute of Technology, Brno University of Technology, Purkyňova 656/123, 612 00 Brno, Czech Republic
2 shared publicationsJan Gregora
Department of Tribology, Faculty of Mechanical Engineering, Brno University of Technology, Technická 2896/2, 616 69 Brno, Czech Republic
2 shared publications- Klara Tuslova
Advanced Biomaterials Group, Central European Institute of Technology
2 shared publications Martin Vrbka
Department of Tribology, Faculty of Mechanical Engineering, Brno University of Technology, Technická 2896/2, 616 69 Brno, Czech Republic
2 shared publications
Latest Publications
- Open Access
- 30 October 2026
- Published by Elsevier in SSRN Electronic Journal
Compatibility of Mozafari Liposomes with Conventional Downsizing: Membrane Fluidity and Vesicle Fusion Governed by DPPC-to-Glycerol Ratio
The Mozafari method is an organic solvent-free, environmentally friendly liposome preparation technique that employs glycerol as a lipid-stabilising agent. Further processing and downsizing, such as sonication or extrusion, which are generally employed in liposome fabrication, are not commonly applied in the Mozafari method. To further decrease the size of the liposomes, we tested the downsizing methods on Mozafari liposomes and investigated the influence of the phosphatidylcholine-to-glycerol (DPPC/GL) ratio on the physical characteristics of the Mozafari liposomes. Liposomes were characterised using DLS and steady-state fluorescence anisotropy of the 1,6-diphenyl-1,3,5-hexatriene (DPH) probe immediately after preparation and after extrusion through polycarbonate membranes. The results showed that the DPPC/GL ratio fundamentally determines bilayer fluidity, vesicle deformability, and susceptibility to fusion events under mechanical stress. Glycerol concentration was fixed at 3% v/v and DPPC/GL molar ratios ranging from 0.02–0.12 were evaluated. A clear dependence of the physicochemical properties of the liposomes on this ratio was observed. At a DPPC/GL ratio of approximately 0.02, the liposomes exhibited high deformability, reduced DPH fluorescence anisotropy, and regular spherical morphology, consistent with a highly fluid membrane. As the ratio increased to 0.12, the membrane progressively became more rigid, as reflected by higher anisotropy values and reduced structural flexibility. During extrusion, vesicle enlargement occurred most prominently at intermediate DPPC/GL ratios, indicating that the combined effects of membrane stiffness, glycerol-mediated modulation of packing, and increased particle density promoted pressure-induced fusion. Our results show that the DPPC/GL molar ratio is a key determinant of membrane fluidity and mechanical response in liposomes.
- 30 October 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessCompatibility of Mozafari Liposomes with Conventional Downsizing: Membrane Fluidity and Vesicle Fusion Governed by DPPC-to-Glycerol Ratio
The Mozafari method is an organic solvent-free, environmentally friendly liposome preparation technique that employs glycerol as a lipid-stabilising agent. Further processing and downsizing, such as sonication or extrusion, which are generally employed in liposome fabrication, are not commonly applied in the Mozafari method. To further decrease the size of the liposomes, we tested the downsizing methods on Mozafari liposomes and investigated the influence of the phosphatidylcholine-to-glycerol (DPPC/GL) ratio on the physical characteristics of the Mozafari liposomes. Liposomes were characterised using DLS and steady-state fluorescence anisotropy of the 1,6-diphenyl-1,3,5-hexatriene (DPH) probe immediately after preparation and after extrusion through polycarbonate membranes. The results showed that the DPPC/GL ratio fundamentally determines bilayer fluidity, vesicle deformability, and susceptibility to fusion events under mechanical stress. Glycerol concentration was fixed at 3% v/v and DPPC/GL molar ratios ranging from 0.02–0.12 were evaluated. A clear dependence of the physicochemical properties of the liposomes on this ratio was observed. At a DPPC/GL ratio of approximately 0.02, the liposomes exhibited high deformability, reduced DPH fluorescence anisotropy, and regular spherical morphology, consistent with a highly fluid membrane. As the ratio increased to 0.12, the membrane progressively became more rigid, as reflected by higher anisotropy values and reduced structural flexibility. During extrusion, vesicle enlargement occurred most prominently at intermediate DPPC/GL ratios, indicating that the combined effects of membrane stiffness, glycerol-mediated modulation of packing, and increased particle density promoted pressure-induced fusion. Our results show that the DPPC/GL molar ratio is a key determinant of membrane fluidity and mechanical response in liposomes.
- Open Access
- 8 December 2025
- Published by American Chemical Society (ACS) in ACS Omega
- Vol. 10 (51) , 63441-63454
Toward Cartilage-Mimicking Biomaterials: Biotribological, Biochemical and Structural Evaluation of pHEMA and PVA-Based Hydrogels
This study compares the biotribological and structural behavior of PVA and pHEMA hydrogels under conditions simulating the cartilage environment to understand the lubrication mechanisms. PVA samples exhibited very low apparent friction coefficients and high-water uptake due to their hydrophilic, hydroxyl-rich network. In contrast, pHEMA hydrogels showed higher friction but substantially enhanced wear resistance, particularly under extended sliding against rough counterfaces. While PVA offers excellent lubrication performance, its wear stability remains limited. On the other hand, the low wear observed in pHEMAdespite its higher frictionsuggests strong structural resilience, making it a promising platform for further tailoring toward cartilage-mimicking applications. The results highlight the importance of balancing interfacial lubrication and mechanical durability when designing hydrogel-based cartilage replacements.
- 8 December 2025
- Published by American Chemical Society (ACS) in ACS Omega
- Vol. 10 (51) , 63441-63454
Open AccessToward Cartilage-Mimicking Biomaterials: Biotribological, Biochemical and Structural Evaluation of pHEMA and PVA-Based Hydrogels
This study compares the biotribological and structural behavior of PVA and pHEMA hydrogels under conditions simulating the cartilage environment to understand the lubrication mechanisms. PVA samples exhibited very low apparent friction coefficients and high-water uptake due to their hydrophilic, hydroxyl-rich network. In contrast, pHEMA hydrogels showed higher friction but substantially enhanced wear resistance, particularly under extended sliding against rough counterfaces. While PVA offers excellent lubrication performance, its wear stability remains limited. On the other hand, the low wear observed in pHEMAdespite its higher frictionsuggests strong structural resilience, making it a promising platform for further tailoring toward cartilage-mimicking applications. The results highlight the importance of balancing interfacial lubrication and mechanical durability when designing hydrogel-based cartilage replacements.
- Open Access
- 15 September 2025
- Published by American Chemical Society (ACS) in ACS Omega
- Vol. 10 (38) , 44147-44161
Biomimetic pHEMA Hydrogels as an Alternative Cartilage-like Model Material for Biotribological Evaluations
Poly-(vinyl alcohol) (PVA) has been widely explored as a model material for articular cartilage (AC) in biotribological evaluations. However, PVA hydrogels prepared by freeze-thawing or cast-drying methods have limitations in precisely controlling their elasticity parameters and may require reinforcement to enhance their mechanical performance and change their transparency, required in some tribological measurement setups by using fluorescence methods. To overcome these issues, poly-(hydroxyethyl methacrylate) (pHEMA) hydrogels have been introduced as alternatives. In our study, pHEMA hydrogels synthesized using free-radical polymerization with blue light under two different atmospheres (nitrogen N2 and air) were compared with natural samples of articular bovine cartilage. The optical, mechanical, swelling, and tribological properties demonstrate the superior properties of pHEMA, which may result in the replacement of the currently used PVA-based model in future studies. Synthesis under a nitrogen atmosphere (pHEMA N 2) resulted in the formation of smooth-surfaced hydrogels, whereas synthesis under a laboratory atmosphere (pHEMA air) resulted in the formation of wrinkled-surfaced hydrogels. The swelling of both the hydrogels and AC followed first-order kinetics. Pin-on-plate biotribology measurements showed that the coefficient of friction of the wrinkled-surface hydrogels resembled that of AC. Our results showed that pHEMA-based hydrogels are suitable biotribological AC models for a better understanding of the biological functions of bovine AC. This knowledge brings new insights into cartilage complex mechanisms and might be applied in both biomedical and engineering applications.
- 15 September 2025
- Published by American Chemical Society (ACS) in ACS Omega
- Vol. 10 (38) , 44147-44161
Open AccessBiomimetic pHEMA Hydrogels as an Alternative Cartilage-like Model Material for Biotribological Evaluations
Poly-(vinyl alcohol) (PVA) has been widely explored as a model material for articular cartilage (AC) in biotribological evaluations. However, PVA hydrogels prepared by freeze-thawing or cast-drying methods have limitations in precisely controlling their elasticity parameters and may require reinforcement to enhance their mechanical performance and change their transparency, required in some tribological measurement setups by using fluorescence methods. To overcome these issues, poly-(hydroxyethyl methacrylate) (pHEMA) hydrogels have been introduced as alternatives. In our study, pHEMA hydrogels synthesized using free-radical polymerization with blue light under two different atmospheres (nitrogen N2 and air) were compared with natural samples of articular bovine cartilage. The optical, mechanical, swelling, and tribological properties demonstrate the superior properties of pHEMA, which may result in the replacement of the currently used PVA-based model in future studies. Synthesis under a nitrogen atmosphere (pHEMA N 2) resulted in the formation of smooth-surfaced hydrogels, whereas synthesis under a laboratory atmosphere (pHEMA air) resulted in the formation of wrinkled-surfaced hydrogels. The swelling of both the hydrogels and AC followed first-order kinetics. Pin-on-plate biotribology measurements showed that the coefficient of friction of the wrinkled-surface hydrogels resembled that of AC. Our results showed that pHEMA-based hydrogels are suitable biotribological AC models for a better understanding of the biological functions of bovine AC. This knowledge brings new insights into cartilage complex mechanisms and might be applied in both biomedical and engineering applications.
- Open Access
- 22 December 2023
- Published by American Chemical Society (ACS) in Biomacromolecules
- Vol. 25 (1) , 67-76
Liposomes Affect Protein Release and Stability of ITA-Modified PLGA–PEG-PLGA Hydrogel Carriers for Controlled Drug Delivery
Fat grafting, a key regenerative medicine technique, often requires repeat procedures due to high-fat reabsorption and volume loss. Addressing this, a novel drug delivery system uniquely combines a thermosensitive, FDA-approved hydrogel (itaconic acid-modified PLGA-PEG-PLGA copolymer) with FGF2-STAB, a stable fibroblast growth factor 2 with a 21-day stability, far exceeding a few hours of wild-type FGF2's stability. Additionally, the growth factor was encapsulated in "green" liposomes prepared via the Mozafari method, ensuring pH protection. The system, characterized by first-order FGF2-STAB release, employs green chemistry for biocompatibility, bioactivity, and eco-friendliness. The liposomes, with diameters of 85.73 ± 3.85 nm and 68.6 ± 2.2% encapsulation efficiency, allowed controlled FGF2-STAB release from the hydrogel compared to the unencapsulated FGF2-STAB. Yet, the protein compromised the carrier's hydrolytic stability. Prior tests were conducted on model proteins human albumin (efficiency 80.8 ± 3.2%) and lysozyme (efficiency 81.0 ± 2.7%). This injectable thermosensitive system could advance reconstructive medicine and cosmetic procedures.
- 22 December 2023
- Published by American Chemical Society (ACS) in Biomacromolecules
- Vol. 25 (1) , 67-76
Open AccessLiposomes Affect Protein Release and Stability of ITA-Modified PLGA–PEG-PLGA Hydrogel Carriers for Controlled Drug Delivery
Fat grafting, a key regenerative medicine technique, often requires repeat procedures due to high-fat reabsorption and volume loss. Addressing this, a novel drug delivery system uniquely combines a thermosensitive, FDA-approved hydrogel (itaconic acid-modified PLGA-PEG-PLGA copolymer) with FGF2-STAB, a stable fibroblast growth factor 2 with a 21-day stability, far exceeding a few hours of wild-type FGF2's stability. Additionally, the growth factor was encapsulated in "green" liposomes prepared via the Mozafari method, ensuring pH protection. The system, characterized by first-order FGF2-STAB release, employs green chemistry for biocompatibility, bioactivity, and eco-friendliness. The liposomes, with diameters of 85.73 ± 3.85 nm and 68.6 ± 2.2% encapsulation efficiency, allowed controlled FGF2-STAB release from the hydrogel compared to the unencapsulated FGF2-STAB. Yet, the protein compromised the carrier's hydrolytic stability. Prior tests were conducted on model proteins human albumin (efficiency 80.8 ± 3.2%) and lysozyme (efficiency 81.0 ± 2.7%). This injectable thermosensitive system could advance reconstructive medicine and cosmetic procedures.