Rong Zhou
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Rong Zhou has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Chuan-Xing Bi
Hefei University of Technology
6 shared publications Xiao-Zheng Zhang
Institute of Sound and Vibration Research, Hefei University of Technology , 193 Tunxi Road, Hefei 230009, People's Republic of China
2 shared publicationsYang Shen
Institute of Sound and Vibration Research, Hefei University of Technology , 193 Tunxi Road, Hefei 230009, People's Republic of China
2 shared publicationsYong-Bin Zhang
Institute of Sound and Vibration Research, Hefei University of Technology , 193 Tunxi Road, Hefei 230009, People's Republic of China
2 shared publications- Yong-Bin Zhang
Institute of Sound and Vibration Research, Hefei University of Technology , 193 Tunxi Road, Hefei 230009, People's Republic of China
2 shared publications - Yong-Chang Li
Institute of Sound and Vibration Research, Hefei University of Technology, 193 Tunxi Road, Hefei 230009, China
2 shared publications
Latest Publications
- 1 August 2024
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 156 (2) , 800-811
Designing a sparse sensor array for sound field reconstruction using compressive-equivalent source method
The compressive-equivalent source method (C-ESM) can reconstruct the sound field radiated by sparsely distributed sound sources with a reduced number of sensors. To ensure the performance of the C-ESM, the transfer matrix between the sensors and equivalent point sources should exhibit sufficient incoherence. Given that the configuration of the sensor array affects this incoherence condition, concern regarding the sensor array design would arise. To address such concern, this paper proposes a sensor array design approach. The primary objective of this approach is to minimize the mean coherence of the transfer matrix within the developed iterative framework, providing the incoherence condition required by the C-ESM. Subsequently, the designed sensor array is utilized by the C-ESM for the reconstructions. The effectiveness and practicality of the proposed approach are validated through numerical simulations and experiments.
- 1 August 2024
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 156 (2) , 800-811
Designing a sparse sensor array for sound field reconstruction using compressive-equivalent source method
The compressive-equivalent source method (C-ESM) can reconstruct the sound field radiated by sparsely distributed sound sources with a reduced number of sensors. To ensure the performance of the C-ESM, the transfer matrix between the sensors and equivalent point sources should exhibit sufficient incoherence. Given that the configuration of the sensor array affects this incoherence condition, concern regarding the sensor array design would arise. To address such concern, this paper proposes a sensor array design approach. The primary objective of this approach is to minimize the mean coherence of the transfer matrix within the developed iterative framework, providing the incoherence condition required by the C-ESM. Subsequently, the designed sensor array is utilized by the C-ESM for the reconstructions. The effectiveness and practicality of the proposed approach are validated through numerical simulations and experiments.
- 1 June 2024
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 155 (6) , 3942-3956
Repairing distorted hologram data for sound field reconstruction
This paper proposes a distorted hologram data repair approach for sound field reconstruction. In this approach, an equivalent source model is established by placing a set of equivalent sources near the hologram surface to represent the measured hologram pressures. Each hologram pressure is simultaneously assigned an indicator to describe whether its measurement is corrupted by errors or not. This model is then formulated within a modal framework by utilizing the modes generated through the singular value decomposition of the transfer matrix between the hologram and nearby equivalent source surfaces. Subsequently, the indicators and modal coefficients are assigned the 0–1 and Gaussian prior distributions, respectively, and their posterior distributions are derived using the Bayesian method. The means of the posterior distributions are calculated to discriminate corrupted measurements and repair distorted hologram pressures. Repaired hologram pressures are finally utilized for reconstructions using the equivalent source method. Results from both numerical simulations conducted under various parameter settings and two experiments demonstrate the effectiveness of the proposed approach in automatically discriminating all the corrupted measurements and accurately repairing the distorted hologram pressures. Furthermore, the accuracy of the reconstructions using the repaired hologram pressures is comparable to that achieved with the correctly measured pressures.
- 1 June 2024
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 155 (6) , 3942-3956
Repairing distorted hologram data for sound field reconstruction
This paper proposes a distorted hologram data repair approach for sound field reconstruction. In this approach, an equivalent source model is established by placing a set of equivalent sources near the hologram surface to represent the measured hologram pressures. Each hologram pressure is simultaneously assigned an indicator to describe whether its measurement is corrupted by errors or not. This model is then formulated within a modal framework by utilizing the modes generated through the singular value decomposition of the transfer matrix between the hologram and nearby equivalent source surfaces. Subsequently, the indicators and modal coefficients are assigned the 0–1 and Gaussian prior distributions, respectively, and their posterior distributions are derived using the Bayesian method. The means of the posterior distributions are calculated to discriminate corrupted measurements and repair distorted hologram pressures. Repaired hologram pressures are finally utilized for reconstructions using the equivalent source method. Results from both numerical simulations conducted under various parameter settings and two experiments demonstrate the effectiveness of the proposed approach in automatically discriminating all the corrupted measurements and accurately repairing the distorted hologram pressures. Furthermore, the accuracy of the reconstructions using the repaired hologram pressures is comparable to that achieved with the correctly measured pressures.
- 22 December 2023
- Published by World Scientific Pub Co Pte Ltd in Journal of Theoretical and Computational Acoustics
- Vol. 32 (01)
Sound Field Reconstruction Using Compressed Separable Projection-Based Equivalent Source Method
The compressive-equivalent source method (C-ESM) has been developed for the sound field reconstruction by solving the [ ] minimization with the predetermined sparsity of the equivalent source strengths. However, the C-ESM would reconstruct the sound field with the error proportional to the measurement noise-related data fidelity constraint that increases with the decrease of the signal-to-noise ratio. Apart from that, the reconstruction stability of the C-ESM would not be guaranteed due to the existence of the measurement noise. To address such problem, the present paper proposes a compressed separable projection-based equivalent source method. In the method, the projections of the measured pressures in the predesigned basis that combines the priors of the sound radiation of the equivalent sources and the measurement noise are obtained by solving the [ ] minimization. This not only leads to the data fidelity constraint being small and unrelated to the measurement noise, but also separates the measurement noise from the measured sound field. Therefore, the proposed method can theoretically reconstruct the sound field more accurately and stably than the C-ESM. Numerical simulations and experiments are carried out to verify the effectiveness of the proposed method.
- 22 December 2023
- Published by World Scientific Pub Co Pte Ltd in Journal of Theoretical and Computational Acoustics
- Vol. 32 (01)
Sound Field Reconstruction Using Compressed Separable Projection-Based Equivalent Source Method
The compressive-equivalent source method (C-ESM) has been developed for the sound field reconstruction by solving the [ ] minimization with the predetermined sparsity of the equivalent source strengths. However, the C-ESM would reconstruct the sound field with the error proportional to the measurement noise-related data fidelity constraint that increases with the decrease of the signal-to-noise ratio. Apart from that, the reconstruction stability of the C-ESM would not be guaranteed due to the existence of the measurement noise. To address such problem, the present paper proposes a compressed separable projection-based equivalent source method. In the method, the projections of the measured pressures in the predesigned basis that combines the priors of the sound radiation of the equivalent sources and the measurement noise are obtained by solving the [ ] minimization. This not only leads to the data fidelity constraint being small and unrelated to the measurement noise, but also separates the measurement noise from the measured sound field. Therefore, the proposed method can theoretically reconstruct the sound field more accurately and stably than the C-ESM. Numerical simulations and experiments are carried out to verify the effectiveness of the proposed method.
- 4 March 2019
- Published by Wiley in Journal of Vibration and Acoustics
- Vol. 141 (3)
Analytical Passive Time Reversal Method Combined With Equivalent Source Method for Sound Source Localization in an Enclosure
The analytical passive time reversal method (APTRM) is a powerful technique for sound source localization. In that technique, it generally requires that the frequency response function relating the measurement point to the focusing point should be known in advance. However, inside an enclosure of arbitrary shape, there is no theoretical formulation of this frequency response function, and using the APTRM with the free-field Green's function might lead to inaccurate localization of sound sources. This paper proposes a method combining the APTRM with the equivalent source method (ESM) to locate sound sources in an enclosure of arbitrary shape. In this method, the frequency response function relating the measurement point to the focusing point inside the enclosure is first calculated numerically using the ESM, and then the APTRM with this numerical frequency response function is used to realize the localization of sound sources. Numerical simulations in a rectangular enclosure and an enclosure of arbitrary shape as well as an experiment in a rectangular wooden cabinet are performed to verify the validity of the proposed method. The results demonstrate that the frequency response function in an enclosure can be accurately calculated using the ESM; based on measurements with a spherical array composed of 48 microphones, the proposed method can effectively locate the sound sources in enclosures of different shapes and work stably under the situation of low signal-to-noise ratio.
- 4 March 2019
- Published by Wiley in Journal of Vibration and Acoustics
- Vol. 141 (3)
Analytical Passive Time Reversal Method Combined With Equivalent Source Method for Sound Source Localization in an Enclosure
The analytical passive time reversal method (APTRM) is a powerful technique for sound source localization. In that technique, it generally requires that the frequency response function relating the measurement point to the focusing point should be known in advance. However, inside an enclosure of arbitrary shape, there is no theoretical formulation of this frequency response function, and using the APTRM with the free-field Green's function might lead to inaccurate localization of sound sources. This paper proposes a method combining the APTRM with the equivalent source method (ESM) to locate sound sources in an enclosure of arbitrary shape. In this method, the frequency response function relating the measurement point to the focusing point inside the enclosure is first calculated numerically using the ESM, and then the APTRM with this numerical frequency response function is used to realize the localization of sound sources. Numerical simulations in a rectangular enclosure and an enclosure of arbitrary shape as well as an experiment in a rectangular wooden cabinet are performed to verify the validity of the proposed method. The results demonstrate that the frequency response function in an enclosure can be accurately calculated using the ESM; based on measurements with a spherical array composed of 48 microphones, the proposed method can effectively locate the sound sources in enclosures of different shapes and work stably under the situation of low signal-to-noise ratio.
- 17 May 2018
- Published by ASME International in Journal of Vibration and Acoustics
- Vol. 140 (6) , 061011
A Comparison of Equivalent Source Method and Monopole Time Reversal Method for Noise Source Localization
The equivalent source method (ESM) and monopole time reversal method (MTRM) are two popular techniques for noise source localization. These two methods have some similar characteristics, such as using the pressure field measured by a microphone array as the input and using similar propagation matrices obtained from the Green's function. However, the spatial resolutions of results obtained by these two methods are different. The aim of this paper is to reveal the reason resulting in this difference from a theoretical analysis and compare the performance of these two methods using results from numerical simulations and experiments. Using the singular value decomposition (SVD) technique, the difference between the two methods is found to be only the diagonal matrices of singular values, and the two methods are equivalent after simply replacing the diagonal matrix in the MTRM with its inverse. Comparison of the results demonstrates that the ESM can calculate the real source strength and obtain a high spatial resolution due to the significant amplification of evanescent waves in the inverse process. However, it does not work when the signal-to-noise ratio (SNR) is low or the measurement distance is large. The performance of ESM under these situations can be significantly improved by introducing a regularization procedure. While the MTRM fails to calculate the real source strength and locate the source at low frequencies due to the loss of information of evanescent waves, it works well at high frequencies even with a low SNR and a large measurement distance.
- 17 May 2018
- Published by ASME International in Journal of Vibration and Acoustics
- Vol. 140 (6) , 061011
A Comparison of Equivalent Source Method and Monopole Time Reversal Method for Noise Source Localization
The equivalent source method (ESM) and monopole time reversal method (MTRM) are two popular techniques for noise source localization. These two methods have some similar characteristics, such as using the pressure field measured by a microphone array as the input and using similar propagation matrices obtained from the Green's function. However, the spatial resolutions of results obtained by these two methods are different. The aim of this paper is to reveal the reason resulting in this difference from a theoretical analysis and compare the performance of these two methods using results from numerical simulations and experiments. Using the singular value decomposition (SVD) technique, the difference between the two methods is found to be only the diagonal matrices of singular values, and the two methods are equivalent after simply replacing the diagonal matrix in the MTRM with its inverse. Comparison of the results demonstrates that the ESM can calculate the real source strength and obtain a high spatial resolution due to the significant amplification of evanescent waves in the inverse process. However, it does not work when the signal-to-noise ratio (SNR) is low or the measurement distance is large. The performance of ESM under these situations can be significantly improved by introducing a regularization procedure. While the MTRM fails to calculate the real source strength and locate the source at low frequencies due to the loss of information of evanescent waves, it works well at high frequencies even with a low SNR and a large measurement distance.
- 1 June 2006
- Published by Springer Nature in Chinese Science Bulletin
- Vol. 51 (11) , 1374-1380
Landweber iterative regularization for nearfield acoustic holography
- 1 June 2006
- Published by Springer Nature in Chinese Science Bulletin
- Vol. 51 (11) , 1374-1380
Landweber iterative regularization for nearfield acoustic holography