Jiawen Deng
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Jiawen Deng has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Jie Yang
School of Software and Microelectronics, Peking University, Beijing, China
2 shared publications - Xing Zhang
School of Integrated Circuits Peking University Beijing China
2 shared publications - Xin’an Wang
School of Software & Microelectronics, Peking University, Beijing, China
2 shared publications - Hongming Chen
School of Information Engineering, Zhejiang Ocean University, ZhouShan, China
1 shared publication - Jieru Ma
School of Integrated Circuits, Peking University, Beijing 100871, China
1 shared publication - Shuyu Liu
Shanghai BU (Xishuo Microelectronic) of RUNIC Technology Co., Ltd., Shanghai 200120, China
1 shared publication
Latest Publications
- Open Access
A Novel Instruction Driven 1-D CNN Processor for ECG Classification
Electrocardiography (ECG) has emerged as a ubiquitous diagnostic tool for the identification and characterization of diverse cardiovascular pathologies. Wearable health monitoring devices, equipped with on-device biomedical artificial intelligence (AI) processors, have revolutionized the acquisition, analysis, and interpretation of ECG data. However, these systems necessitate AI processors that exhibit flexible configuration, facilitate portability, and demonstrate optimal performance in terms of power consumption and latency for the realization of various functionalities. To address these challenges, this study proposes an instruction-driven convolutional neural network (CNN) processor. This processor incorporates three key features: (1) An instruction-driven CNN processor to support versatile ECG-based application. (2) A Processing element (PE) array design that simultaneously considers parallelism and data reuse. (3) An activation unit based on the CORDIC algorithm, supporting both Tanh and Sigmoid computations. The design has been implemented using 110 nm CMOS process technology, occupying a die area of 1.35 mm2 with 12.94 µW power consumption. It has been demonstrated with two typical ECG AI applications, including two-class (i.e., normal/abnormal) classification and five-class classification. The proposed 1-D CNN algorithm performs with a 97.95% accuracy for the two-class classification and 97.9% for the five-class classification, respectively.
Open AccessA Novel Instruction Driven 1-D CNN Processor for ECG Classification
Electrocardiography (ECG) has emerged as a ubiquitous diagnostic tool for the identification and characterization of diverse cardiovascular pathologies. Wearable health monitoring devices, equipped with on-device biomedical artificial intelligence (AI) processors, have revolutionized the acquisition, analysis, and interpretation of ECG data. However, these systems necessitate AI processors that exhibit flexible configuration, facilitate portability, and demonstrate optimal performance in terms of power consumption and latency for the realization of various functionalities. To address these challenges, this study proposes an instruction-driven convolutional neural network (CNN) processor. This processor incorporates three key features: (1) An instruction-driven CNN processor to support versatile ECG-based application. (2) A Processing element (PE) array design that simultaneously considers parallelism and data reuse. (3) An activation unit based on the CORDIC algorithm, supporting both Tanh and Sigmoid computations. The design has been implemented using 110 nm CMOS process technology, occupying a die area of 1.35 mm2 with 12.94 µW power consumption. It has been demonstrated with two typical ECG AI applications, including two-class (i.e., normal/abnormal) classification and five-class classification. The proposed 1-D CNN algorithm performs with a 97.95% accuracy for the two-class classification and 97.9% for the five-class classification, respectively.
- Open Access
- 29 December 2023
- Published by MDPI AG in Applied Sciences
- Vol. 14 (1) , 342
An Energy-Efficient ECG Processor Based on HDWT and a Hybrid Classifier for Arrhythmia Detection
Cardiac arrhythmia (CA) is a severe cardiac disorder that results in a significant number of fatalities worldwide each year. Conventional electrocardiography (ECG) devices are often unable to detect arrhythmia symptoms during patients’ hospital visits due to their intermittent nature. This paper presents a wearable ECG processor for cardiac arrhythmia (CA) detection. The processor utilizes a Hilbert transform-based R-peak detection engine for R-peak detection, a Haar discrete wavelet transform (HDWT) unit for feature extraction, and a Hybrid ECG classifier that combines linear methods and Non-Linear Support Vector Machines (NLSVM) classifiers to distinguish between normal and abnormal heartbeats. The processor is fabricated by the CMOS 110 nm process with an area of 1.34 mm2 and validated with the MIT_BIH Database. The whole design consumes 4.08 μW with an average classification accuracy of 97.34%.
- 29 December 2023
- Published by MDPI AG in Applied Sciences
- Vol. 14 (1) , 342
Open AccessAn Energy-Efficient ECG Processor Based on HDWT and a Hybrid Classifier for Arrhythmia Detection
Cardiac arrhythmia (CA) is a severe cardiac disorder that results in a significant number of fatalities worldwide each year. Conventional electrocardiography (ECG) devices are often unable to detect arrhythmia symptoms during patients’ hospital visits due to their intermittent nature. This paper presents a wearable ECG processor for cardiac arrhythmia (CA) detection. The processor utilizes a Hilbert transform-based R-peak detection engine for R-peak detection, a Haar discrete wavelet transform (HDWT) unit for feature extraction, and a Hybrid ECG classifier that combines linear methods and Non-Linear Support Vector Machines (NLSVM) classifiers to distinguish between normal and abnormal heartbeats. The processor is fabricated by the CMOS 110 nm process with an area of 1.34 mm2 and validated with the MIT_BIH Database. The whole design consumes 4.08 μW with an average classification accuracy of 97.34%.