Ge Chen has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
- Dawei Feng
State Key Laboratory of Power Transmission Equipment Technology, Chongqing University, Chongqing, China
2 shared publications Dong Li
SINOPEC Northwest Oil Field Company China
1 shared publicationDongrong Wu
PipeChina Southwest Pipeline Company China
1 shared publicationHaocen Li
College of Safety and Ocean Engineering, China University of Petroleum, Beijing, 102249, China
1 shared publication- Jiayue Liu
State Key Laboratory of Quality Research in Chinese Medicine, Institute of Chinese Medical Sciences, University of Macau, Macao
1 shared publication Jie Lan
SINOPEC Northwest Oil Field Company China
1 shared publication
Latest Publications
- 14 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 32 (3) , 1820-1826
Production Pattern of Furfural in Esters-Immersed Paper and Aging Evaluation Methods
With the increasing requirements of environment protection and fire prevention, esters insulation oils including natural esters and synthetic esters have been widely used in transformers. Studies have shown that esters can retard the aging rate of insulation paper. However, whether the aging-delaying phenomenon affects the production pattern of furfural and the aging assessment models is not yet known. To address this issue, accelerated thermal aging experiments with different oil-paper systems were carried out and discussed. The results indicate that esters insulation oils can delay the aging rate of insulation paper while also reducing the furfural production amount. Upon degree of polymerization (DP) values of insulation paper decreasing to 550, the total furfural amount produced in the synthetic ester, soybean oil, and linseed oil-paper systems is 0.8, 0.59 and 0.54 times that in the mineral oil-paper system, respectively. This discrepancy is attributed to significant differences in moisture solubility and oxidative stability among different insulation oils, which decreases the moisture content in esters immersed insulation paper and oxidative degradation process, thereby decreasing the total furfural amount. In order to eliminate the impact of various insulation oils on the furfural assessment model, the relationship between furfural contents and DP values in different esters should be reestablished.
- 14 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 32 (3) , 1820-1826
Production Pattern of Furfural in Esters-Immersed Paper and Aging Evaluation Methods
With the increasing requirements of environment protection and fire prevention, esters insulation oils including natural esters and synthetic esters have been widely used in transformers. Studies have shown that esters can retard the aging rate of insulation paper. However, whether the aging-delaying phenomenon affects the production pattern of furfural and the aging assessment models is not yet known. To address this issue, accelerated thermal aging experiments with different oil-paper systems were carried out and discussed. The results indicate that esters insulation oils can delay the aging rate of insulation paper while also reducing the furfural production amount. Upon degree of polymerization (DP) values of insulation paper decreasing to 550, the total furfural amount produced in the synthetic ester, soybean oil, and linseed oil-paper systems is 0.8, 0.59 and 0.54 times that in the mineral oil-paper system, respectively. This discrepancy is attributed to significant differences in moisture solubility and oxidative stability among different insulation oils, which decreases the moisture content in esters immersed insulation paper and oxidative degradation process, thereby decreasing the total furfural amount. In order to eliminate the impact of various insulation oils on the furfural assessment model, the relationship between furfural contents and DP values in different esters should be reestablished.
- 12 September 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 30 (6) , 2758-2768
Furfural Analysis on Aging State Assessment of Oil-Immersed Transformers: A Review
Furfural analysis is widely used in aging state assessment of oil-immersed transformers due to its close relationship with the degradation of insulation paper. Herein, we present a critical overview of important insights and progress on furfural analysis, including production mechanism, measurement progress, production amount, stability, and distribution law of furfural in oil-paper systems. The relationship between furfural content in oil and polymerization degree (DP) of insulation paper is also analyzed. Considering the engineering application of furfural analysis for field transformers, the authors’ viewpoints regarding present problems and challenges are further discussed, and prospective development directions for furfural analysis are proposed for future research.
- 12 September 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 30 (6) , 2758-2768
Furfural Analysis on Aging State Assessment of Oil-Immersed Transformers: A Review
Furfural analysis is widely used in aging state assessment of oil-immersed transformers due to its close relationship with the degradation of insulation paper. Herein, we present a critical overview of important insights and progress on furfural analysis, including production mechanism, measurement progress, production amount, stability, and distribution law of furfural in oil-paper systems. The relationship between furfural content in oil and polymerization degree (DP) of insulation paper is also analyzed. Considering the engineering application of furfural analysis for field transformers, the authors’ viewpoints regarding present problems and challenges are further discussed, and prospective development directions for furfural analysis are proposed for future research.
- Open Access
- 1 September 2021
- Published by IOP Publishing in IOP Conference Series: Earth and Environmental Science
- Vol. 859 (1) , 012112
Fuzzy Comprehensive Hierarchical Evaluation Model for Lightning Disaster in Oil Storage Depots
An oil storage depot is one of the most dangerous places in the petrochemical industry. Lightning strikes present a significant risk to the regular operation of oil storage depots and the safety of the staff. This paper established a lightning disaster risk model using practical evaluation techniques to provide insight into the lightning disaster prevention methods used in oil storage depots both domestically and abroad. The risk assessment of lightning disaster in oil storage depots was performed according to this model, after which the risk index factors were classified. Furthermore, this paper reasonably resolved the problems surrounding the limited use of lightning protection standards and the challenge in quantifying the qualitative factors during lightning disaster risk assessment in oil storage depots. This references the risk assessment of lightning disaster in oil storage depots and the related lightning protection design.
- 1 September 2021
- Published by IOP Publishing in IOP Conference Series: Earth and Environmental Science
- Vol. 859 (1) , 012112
Open AccessFuzzy Comprehensive Hierarchical Evaluation Model for Lightning Disaster in Oil Storage Depots
An oil storage depot is one of the most dangerous places in the petrochemical industry. Lightning strikes present a significant risk to the regular operation of oil storage depots and the safety of the staff. This paper established a lightning disaster risk model using practical evaluation techniques to provide insight into the lightning disaster prevention methods used in oil storage depots both domestically and abroad. The risk assessment of lightning disaster in oil storage depots was performed according to this model, after which the risk index factors were classified. Furthermore, this paper reasonably resolved the problems surrounding the limited use of lightning protection standards and the challenge in quantifying the qualitative factors during lightning disaster risk assessment in oil storage depots. This references the risk assessment of lightning disaster in oil storage depots and the related lightning protection design.
- Open Access
- 1 September 2021
- Published by IOP Publishing in IOP Conference Series: Earth and Environmental Science
- Vol. 859 (1) , 012114
Risk Evaluation Indicator System for Lightning Disaster in Oil Storage Depots
Since oil storage depots typically hold large quantities of oil or gas, they are prone to the build-up of high energy and density levels. This paper established a lightning disaster risk assessment index system for oil storage depots that considered the primary causes for accidental explosions due to lightning and included four first-level, 13 second-level, and 13 third-level indexes. Furthermore, this index system was based on the analysis of the mechanism underlying lightning-causing accidents in different types of storage tanks. Furthermore, it involved the establishment principle for the comprehensive evaluation indicator system, denoting a "comprehensive system, distinct layering, and simplicity." This system includes four first-level evaluation index, 13 second-level evaluation index and 13 third-level evaluation index. It visualizes the affiliation relationship between different risks that may cause lightning accidents in oil storage depots, introduces the method used to obtain each underlying risk indicator and lays a theoretical foundation for assessing the lightning disaster risk in oil storage depots.
- 1 September 2021
- Published by IOP Publishing in IOP Conference Series: Earth and Environmental Science
- Vol. 859 (1) , 012114
Open AccessRisk Evaluation Indicator System for Lightning Disaster in Oil Storage Depots
Since oil storage depots typically hold large quantities of oil or gas, they are prone to the build-up of high energy and density levels. This paper established a lightning disaster risk assessment index system for oil storage depots that considered the primary causes for accidental explosions due to lightning and included four first-level, 13 second-level, and 13 third-level indexes. Furthermore, this index system was based on the analysis of the mechanism underlying lightning-causing accidents in different types of storage tanks. Furthermore, it involved the establishment principle for the comprehensive evaluation indicator system, denoting a "comprehensive system, distinct layering, and simplicity." This system includes four first-level evaluation index, 13 second-level evaluation index and 13 third-level evaluation index. It visualizes the affiliation relationship between different risks that may cause lightning accidents in oil storage depots, introduces the method used to obtain each underlying risk indicator and lays a theoretical foundation for assessing the lightning disaster risk in oil storage depots.