Huadong Sun
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Huadong Sun has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Shiyun Xu
China National Key Laboratory of Power Grid Security, China Electric Power Research Institute, Beijing, China
3 shared publications - Yiming Wang
China Electric Power Research Institute (CEPRI), Beijing, China
3 shared publications - Chen Shen
Tsinghua University
2 shared publications Bing Zhao
China Electric Power Research Institute, Beijing, China
1 shared publication- Tiankai Lan
China Electric Power Research Institute (CEPRI), Beijing, China
1 shared publication
Latest Publications
- 8 August 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Systems
- Vol. 40 (2) , 1518-1531
Transient Stability Analysis of the CIG-Embedded Power Systems Considering Multiple Stable Equilibrium Points
The present research focuses on the transient stability of power systems embedded with a high penetration of converter-interfaced generation (CIG). It is investigated that under large disturbances, power systems with CIGs may exhibit the characteristic of multiple stable equilibrium points (SEPs). This characteristic and its associated stability potential have not been thoroughly studied in conventional power systems, primarily due to the prevalent assumption of a single SEP constrained by the physical limitations of the large-capacity synchronous generator. Since the critical clearing time (CCT) is no longer able to determine system transient stability with multiple SEPs, the absolute instability boundary (AIB) condition is proposed. It is found that if the trajectory surpasses the AIB, the power system will be unable to maintain stability after large disturbances. In what follows, an energy function is introduced to assess transient stability considering multiple SEPs. At the end of the study, the impact of CIG's frequency limiters on transient stability is studied, and a transient stability enhancement method is derived based on the AIB condition and safety constraints. This provides a basis for CIGs with millisecond-level dynamics to respond to power systems with near-second dynamics. Numerical simulations demonstrate the effectiveness of the proposed theoretical results.
- 8 August 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Systems
- Vol. 40 (2) , 1518-1531
Transient Stability Analysis of the CIG-Embedded Power Systems Considering Multiple Stable Equilibrium Points
The present research focuses on the transient stability of power systems embedded with a high penetration of converter-interfaced generation (CIG). It is investigated that under large disturbances, power systems with CIGs may exhibit the characteristic of multiple stable equilibrium points (SEPs). This characteristic and its associated stability potential have not been thoroughly studied in conventional power systems, primarily due to the prevalent assumption of a single SEP constrained by the physical limitations of the large-capacity synchronous generator. Since the critical clearing time (CCT) is no longer able to determine system transient stability with multiple SEPs, the absolute instability boundary (AIB) condition is proposed. It is found that if the trajectory surpasses the AIB, the power system will be unable to maintain stability after large disturbances. In what follows, an energy function is introduced to assess transient stability considering multiple SEPs. At the end of the study, the impact of CIG's frequency limiters on transient stability is studied, and a transient stability enhancement method is derived based on the AIB condition and safety constraints. This provides a basis for CIGs with millisecond-level dynamics to respond to power systems with near-second dynamics. Numerical simulations demonstrate the effectiveness of the proposed theoretical results.
- 6 June 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Systems
- Vol. 40 (1) , 893-906
Stability Boundary of Power System With Converter Interfaced Generation: Evolution and Transition Point
Recent studies indicate that transient instability in power systems with converter interfaced generation (CIG) is primarily related to unstable periodic orbit (UPO) rather than unstable equilibrium point (UEP). This phenomenon is noticeable in weak grids, emphasizing the importance of studying the evolution of the stability boundary's dominant, from UEP to UPO. To address this, the present study introduces a novel transient stability analysis framework for power systems, which relies on the energy-angle complex vector. Both the identification of transition point of the stability boundary and the stability margin assessment are conducted under this framework. It is revealed that variations in parameter conditions, such as an increased proportion of CIG, a decrease in system strength, and inadequate control parameters for CIG, may lead to the dominance of UPO in shaping the stability boundary. This may lead to the ineffectiveness and non-conservatism of the UEP-based criteria. Simulation results demonstrate the effectiveness of the derived conclusions. With the increasing integration scale of CIG, the growing importance of UPO-based stability characteristic will become pronounced in future power systems.
- 6 June 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Systems
- Vol. 40 (1) , 893-906
Stability Boundary of Power System With Converter Interfaced Generation: Evolution and Transition Point
Recent studies indicate that transient instability in power systems with converter interfaced generation (CIG) is primarily related to unstable periodic orbit (UPO) rather than unstable equilibrium point (UEP). This phenomenon is noticeable in weak grids, emphasizing the importance of studying the evolution of the stability boundary's dominant, from UEP to UPO. To address this, the present study introduces a novel transient stability analysis framework for power systems, which relies on the energy-angle complex vector. Both the identification of transition point of the stability boundary and the stability margin assessment are conducted under this framework. It is revealed that variations in parameter conditions, such as an increased proportion of CIG, a decrease in system strength, and inadequate control parameters for CIG, may lead to the dominance of UPO in shaping the stability boundary. This may lead to the ineffectiveness and non-conservatism of the UEP-based criteria. Simulation results demonstrate the effectiveness of the derived conclusions. With the increasing integration scale of CIG, the growing importance of UPO-based stability characteristic will become pronounced in future power systems.
- 16 February 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Systems
- Vol. 39 (1) , 1979-1995
Transient Stability Analysis and Improvement for the Grid-Connected VSC System With Multi-Limiters
As a widely configured controller, the limiter is essential to ensure the security of the voltage source converter (VSC), which affects the stability characteristics of the grid-connected VSC system under severe faults. However, due to limiters' hard algebraic constraints, the existing methods have yet to reveal the stability mechanism related to the multi-limiters thoroughly. In this paper, the stability mechanism of the grid-connected VSC system with multi-limiters is investigated, and an improved Filippov Theorem is proposed to study the dynamic characteristics. Two kinds of points are essential to the stability, namely, the fixed switching point(FSP) and the fixed ending point(FEP). Expressly, transient stability can be guaranteed by the condition that FSP is in the region of attraction(ROA), even if other parts of the trajectory are outside the ROA. Moreover, the existence of FEP contributes to some control loop failure, which does not induce instability but may cause the power into the grid to be inconsistent with the reference value. This paper presents the analytical methods for these crucial points, which avoid time-domain simulation. What follows illustrates how to enhance the stability characteristics by configuring the FSP and FEP. Another advantage of the proposed method is easily extended to the VSC with multi-limiters and different control structures.
- 16 February 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Systems
- Vol. 39 (1) , 1979-1995
Transient Stability Analysis and Improvement for the Grid-Connected VSC System With Multi-Limiters
As a widely configured controller, the limiter is essential to ensure the security of the voltage source converter (VSC), which affects the stability characteristics of the grid-connected VSC system under severe faults. However, due to limiters' hard algebraic constraints, the existing methods have yet to reveal the stability mechanism related to the multi-limiters thoroughly. In this paper, the stability mechanism of the grid-connected VSC system with multi-limiters is investigated, and an improved Filippov Theorem is proposed to study the dynamic characteristics. Two kinds of points are essential to the stability, namely, the fixed switching point(FSP) and the fixed ending point(FEP). Expressly, transient stability can be guaranteed by the condition that FSP is in the region of attraction(ROA), even if other parts of the trajectory are outside the ROA. Moreover, the existence of FEP contributes to some control loop failure, which does not induce instability but may cause the power into the grid to be inconsistent with the reference value. This paper presents the analytical methods for these crucial points, which avoid time-domain simulation. What follows illustrates how to enhance the stability characteristics by configuring the FSP and FEP. Another advantage of the proposed method is easily extended to the VSC with multi-limiters and different control structures.