IKIvan K. Kurkan

Ivan K. Kurkan

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Ivan K. Kurkan has a total of 4 co-authors. Here are the top co-authors by number of shared publications:

  • Alexey I. Klimov

    Institute of High Current Electronics (IHCE) SD RAS Akademichesky Ave. 2/3 634055 Tomsk Russia

    1 shared publication
  • N. M. Bykov

    Institute of High Current Electronics of the Siberian Branch of the Russian Academy of Sciences, Tomsk, Russia

    1 shared publication
  • Pavel V. Priputnev

    Institute of High Current Electronics (IHCE) SD RAS Akademichesky Ave. 2/3 634055 Tomsk Russia

    1 shared publication
  • Vladislav V. Rostov

    Institute of High Current Electronics (IHCE) SD RAS Akademichesky Ave. 2/3 634055 Tomsk Russia

    1 shared publication

Latest Publications

  • Wideband TEM-TM01 Mode Transducer

    by I. K. Kurkan, N. M. Bykov


  • Open Access

    NUMERICAL SIMULATION OF WIDEBAND CALORIMETER FOR HIGH POWER MICROWAVE

    by Ivan K. Kurkan, Alexey I. Klimov, Pavel V. Priputnev, Vladislav V. Rostov

    The novel design of an ultra-wideband calorimeter for energy measurement of high power microwave pulses of nanosecond duration is proposed in this paper. The main idea is the use of a circular waveguide with losses in the wall and metal cone insertion at the axis to increase attenuation constant in the waveguide. The efficiency of the concept was proved with the numeric simulation and optimization of the calorimeter design with ANSYS HFSS software for frequencies from 8 to 38 GHz. The operating modes are supposed to be symmetric TM 0n ones. Ethanol was chosen as an absorbing medium. It is parted from the vacuum volume by a plastic tube. The frequency dependencies of ethanol's relative permittivity and loss tangent were taken into account in the simulation model. The reflection coefficient for TM 01 mode is below-20 dB at the lowest frequency of 8 GHz and well below the level of-25 dB from 10 to 38 GHz. The reflection coefficients for higher order modes remain below-30 dB until the operating frequency is close to the cutoff frequency for a particular mode. The maximum accepted power level is of hundreds of megawatts for pulses of a nanoseconds duration. The effect of waveguide modes mixture at the input of the calorimeter on the maximum accepted power level was considered. This level may differ by 4 times between specific modes mixtures. Therefore, the transition from a particular microwave source to the calorimeter input should be carefully optimized.