Ivan K. Kurkan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Ivan K. Kurkan has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
Alexey I. Klimov
Institute of High Current Electronics (IHCE) SD RAS Akademichesky Ave. 2/3 634055 Tomsk Russia
1 shared publicationN. M. Bykov
Institute of High Current Electronics of the Siberian Branch of the Russian Academy of Sciences, Tomsk, Russia
1 shared publicationPavel V. Priputnev
Institute of High Current Electronics (IHCE) SD RAS Akademichesky Ave. 2/3 634055 Tomsk Russia
1 shared publicationVladislav V. Rostov
Institute of High Current Electronics (IHCE) SD RAS Akademichesky Ave. 2/3 634055 Tomsk Russia
1 shared publication
Latest Publications
- 29 December 2023
- Published by Springer Nature in Russian Physics Journal
- Vol. 66 (12) , 1334-1339
Wideband TEM-TM01 Mode Transducer
- 29 December 2023
- Published by Springer Nature in Russian Physics Journal
- Vol. 66 (12) , 1334-1339
Wideband TEM-TM01 Mode Transducer
- Open Access
- 1 January 2020
- Published by The Electromagnetics Academy in Progress In Electromagnetics Research M
- Vol. 92, 79-88
NUMERICAL SIMULATION OF WIDEBAND CALORIMETER FOR HIGH POWER MICROWAVE
The novel design of an ultra-wideband calorimeter for energy measurement of high power microwave pulses of nanosecond duration is proposed in this paper. The main idea is the use of a circular waveguide with losses in the wall and metal cone insertion at the axis to increase attenuation constant in the waveguide. The efficiency of the concept was proved with the numeric simulation and optimization of the calorimeter design with ANSYS HFSS software for frequencies from 8 to 38 GHz. The operating modes are supposed to be symmetric TM 0n ones. Ethanol was chosen as an absorbing medium. It is parted from the vacuum volume by a plastic tube. The frequency dependencies of ethanol's relative permittivity and loss tangent were taken into account in the simulation model. The reflection coefficient for TM 01 mode is below-20 dB at the lowest frequency of 8 GHz and well below the level of-25 dB from 10 to 38 GHz. The reflection coefficients for higher order modes remain below-30 dB until the operating frequency is close to the cutoff frequency for a particular mode. The maximum accepted power level is of hundreds of megawatts for pulses of a nanoseconds duration. The effect of waveguide modes mixture at the input of the calorimeter on the maximum accepted power level was considered. This level may differ by 4 times between specific modes mixtures. Therefore, the transition from a particular microwave source to the calorimeter input should be carefully optimized.
- 1 January 2020
- Published by The Electromagnetics Academy in Progress In Electromagnetics Research M
- Vol. 92, 79-88
Open AccessNUMERICAL SIMULATION OF WIDEBAND CALORIMETER FOR HIGH POWER MICROWAVE
The novel design of an ultra-wideband calorimeter for energy measurement of high power microwave pulses of nanosecond duration is proposed in this paper. The main idea is the use of a circular waveguide with losses in the wall and metal cone insertion at the axis to increase attenuation constant in the waveguide. The efficiency of the concept was proved with the numeric simulation and optimization of the calorimeter design with ANSYS HFSS software for frequencies from 8 to 38 GHz. The operating modes are supposed to be symmetric TM 0n ones. Ethanol was chosen as an absorbing medium. It is parted from the vacuum volume by a plastic tube. The frequency dependencies of ethanol's relative permittivity and loss tangent were taken into account in the simulation model. The reflection coefficient for TM 01 mode is below-20 dB at the lowest frequency of 8 GHz and well below the level of-25 dB from 10 to 38 GHz. The reflection coefficients for higher order modes remain below-30 dB until the operating frequency is close to the cutoff frequency for a particular mode. The maximum accepted power level is of hundreds of megawatts for pulses of a nanoseconds duration. The effect of waveguide modes mixture at the input of the calorimeter on the maximum accepted power level was considered. This level may differ by 4 times between specific modes mixtures. Therefore, the transition from a particular microwave source to the calorimeter input should be carefully optimized.