Yanling Li
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Yanling Li has a total of 36 co-authors. Here are the top co-authors by number of shared publications:
- Xin Dai
School of Automation, Chongqing University, Chongqing, China
16 shared publications - Udaya Kumara Madawala
University of Auckland
6 shared publications - Ruozhong Gao
School of Automation, Chongqing University, Chongqing, China
4 shared publications - Fengwei Chen
Chongqing University
3 shared publications - Liuping Wang
Royal Melbourne Institute of Technology
3 shared publications - Shijun Zhao
School of Automation, Chongqing University, Chongqing, China
3 shared publications
Latest Publications
- 19 May 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. PP (08858993) , 1-12
Network Topology Dynamic Variation Method Based on Matrix Efficiency Model for Online Path Optimization of WPTN System
Wireless power transfer network (WPTN) extends conventional WPT into distributed multi-node systems with relay-based power routing. However, the complexity of network topology poses significant challenges for path optimization. This paper proposed a matrix-based efficiency path optimization (MEPO) strategy that enables online adaptive routing without offline training or iterative solving. A unified frequency-domain model is established, allowing path efficiency and voltage feasibility to be determined analytically from the network parameters. This model captures all cross-coupling effects and yields expressions for optimal operating parameters. The mutual inductance matrix is reconstructed in real time using NSGA-II, which requires only coil current measurements, enabling adaptive operation under varying topologies. Experiments on a four-node prototype validate the method under dynamic topology variations, achieving up to 90% efficiency.
- 19 May 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. PP (08858993) , 1-12
Network Topology Dynamic Variation Method Based on Matrix Efficiency Model for Online Path Optimization of WPTN System
Wireless power transfer network (WPTN) extends conventional WPT into distributed multi-node systems with relay-based power routing. However, the complexity of network topology poses significant challenges for path optimization. This paper proposed a matrix-based efficiency path optimization (MEPO) strategy that enables online adaptive routing without offline training or iterative solving. A unified frequency-domain model is established, allowing path efficiency and voltage feasibility to be determined analytically from the network parameters. This model captures all cross-coupling effects and yields expressions for optimal operating parameters. The mutual inductance matrix is reconstructed in real time using NSGA-II, which requires only coil current measurements, enabling adaptive operation under varying topologies. Experiments on a four-node prototype validate the method under dynamic topology variations, achieving up to 90% efficiency.
- 10 April 2026
- Published by Springer Nature in Electrical Engineering
- Vol. 108 (4) , 248
Discovering autonomous CC-to-CV transition characteristics of wireless charging system using frequency tracking for large coupling and load variation tolerance
- 10 April 2026
- Published by Springer Nature in Electrical Engineering
- Vol. 108 (4) , 248
Discovering autonomous CC-to-CV transition characteristics of wireless charging system using frequency tracking for large coupling and load variation tolerance
- 21 November 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 41 (5) , 8636-8648
WPT Network Topology Self-Organizing Strategy for Multi Power-Flow Optimization Using Node Role Change and Duty-Cycle Regulation
Wireless power transfer network enables flexible multidevice charging, but optimizing performance under simultaneous power flows is challenging due to complex cross-coupling and time-varying network topologies. This article presents a topology self-organizing strategy that dynamically reconfigures discrete network topologies and jointly tunes duty cycles to maximize network-wide efficiency under concurrent power flows. A hierarchical framework reduces computational burden: the upper layer screens feasible topologies using an online estimate of maximum transferable power, and the lower layer applies chaos-game optimization (CGO) with penalty-based constraint handling to determine the duty-cycle vector that maximizes efficiency subject to power and current limits. By coordinating power-flow strengths and node role changes, the proposed strategy improves overall efficiency and can approach near-optimal performance, without requiring auxiliary compensation or regulation hardware. Experimental results on a hardware prototype with five nodes validate the approach, demonstrating accurate power allocation and improved efficiency across diverse coupling conditions and load demands.
- 21 November 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 41 (5) , 8636-8648
WPT Network Topology Self-Organizing Strategy for Multi Power-Flow Optimization Using Node Role Change and Duty-Cycle Regulation
Wireless power transfer network enables flexible multidevice charging, but optimizing performance under simultaneous power flows is challenging due to complex cross-coupling and time-varying network topologies. This article presents a topology self-organizing strategy that dynamically reconfigures discrete network topologies and jointly tunes duty cycles to maximize network-wide efficiency under concurrent power flows. A hierarchical framework reduces computational burden: the upper layer screens feasible topologies using an online estimate of maximum transferable power, and the lower layer applies chaos-game optimization (CGO) with penalty-based constraint handling to determine the duty-cycle vector that maximizes efficiency subject to power and current limits. By coordinating power-flow strengths and node role changes, the proposed strategy improves overall efficiency and can approach near-optimal performance, without requiring auxiliary compensation or regulation hardware. Experimental results on a hardware prototype with five nodes validate the approach, demonstrating accurate power allocation and improved efficiency across diverse coupling conditions and load demands.
- 9 October 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 41 (4) , 6981-7003
Dynamic Performance Enhancement for Multiexcitation-Units WPT System Using Data-Driven Modeling and Matrix-Inversion-Free Model Predictive Control
The multiexcitation-units wireless power transfer (MEU-WPT) system supports multilevel power applications by adjusting the number of excitation units. Its inherent redundancy enhances reliability against inverter failures, making it ideal for wireless electric vehicle and underwater vehicle charging. However, the incorporation of the MEU structure increases the number of control variables (such as the phase-shift angles of the inverters) and introduces cross couplings among different power units, resulting in complex power transfer channels and interconnected feedback loops, where variations in one control variable generate disturbances in other channels. Consequently, achieving high dynamic performance in output regulation becomes challenging without effective coordination of all control variables. This article proposes a constrained model predictive control (MPC) method aimed at achieving high dynamic performance in output regulation for the MEU-WPT system with cross couplings. Initially, a data-driven simplified refined instrumental variable method is employed to model the MEU-WPT system, capturing the dynamics associated with the cross couplings. Subsequently, a Laguerre-network based multivariable MPC control law is derived from the data-driven models. A matrix-inversion-free quadratic programming solver is developed to enable computationally-efficient constrained optimization. Furthermore, an event-triggered mechanism is integrated into the control framework, demonstrating the potential for rapid switching between different input power allocations among excitation units. An MEU-WPT prototype featuring two excitation units is constructed to validate the feasibility of the proposed control approach.
- 9 October 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 41 (4) , 6981-7003
Dynamic Performance Enhancement for Multiexcitation-Units WPT System Using Data-Driven Modeling and Matrix-Inversion-Free Model Predictive Control
The multiexcitation-units wireless power transfer (MEU-WPT) system supports multilevel power applications by adjusting the number of excitation units. Its inherent redundancy enhances reliability against inverter failures, making it ideal for wireless electric vehicle and underwater vehicle charging. However, the incorporation of the MEU structure increases the number of control variables (such as the phase-shift angles of the inverters) and introduces cross couplings among different power units, resulting in complex power transfer channels and interconnected feedback loops, where variations in one control variable generate disturbances in other channels. Consequently, achieving high dynamic performance in output regulation becomes challenging without effective coordination of all control variables. This article proposes a constrained model predictive control (MPC) method aimed at achieving high dynamic performance in output regulation for the MEU-WPT system with cross couplings. Initially, a data-driven simplified refined instrumental variable method is employed to model the MEU-WPT system, capturing the dynamics associated with the cross couplings. Subsequently, a Laguerre-network based multivariable MPC control law is derived from the data-driven models. A matrix-inversion-free quadratic programming solver is developed to enable computationally-efficient constrained optimization. Furthermore, an event-triggered mechanism is integrated into the control framework, demonstrating the potential for rapid switching between different input power allocations among excitation units. An MEU-WPT prototype featuring two excitation units is constructed to validate the feasibility of the proposed control approach.
- 29 September 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 41 (2) , 3035-3045
Gradient Descent-Based Online Mutual Inductances Identification and Transfer Route Optimization for Dynamically Reconfigurable WPT Network
Wireless Power Transfer Network (WPTN), with their multidimensional dynamic magnetic coupling capabilities, address the limitations of traditional wireless power transfer (WPT) technologies in terms of degrees of freedom, thus advancing the development and application of WPT technologies. Accurate mutual inductance identification is essential for establishing and optimizing paths in WPTN systems. However, the dynamic nature of the network causes frequent changes in mutual inductance parameters as nodes join or leave. This makes traditional calculation methods inadequate for complex multinode network. To address this challenge, this article proposes a dynamic mutual inductance identification method based on the gradient descent algorithm. The method effectively handles simultaneous changes in multiple mutual inductance parameters caused by network topology variations. By constructing a mathematical model of the WPTN system and designing a gradient descent algorithm with adaptive learning rates, the method achieves synchronous identification of multiple mutual inductance parameters. It does not require pretraining or extensive computational resources, and supports both online and offline identification. Experimental results on a four-node system platform show that the proposed method can identify three new mutual inductances in real time during node switching, while dynamically selecting the most efficient transmission path.
- 29 September 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 41 (2) , 3035-3045
Gradient Descent-Based Online Mutual Inductances Identification and Transfer Route Optimization for Dynamically Reconfigurable WPT Network
Wireless Power Transfer Network (WPTN), with their multidimensional dynamic magnetic coupling capabilities, address the limitations of traditional wireless power transfer (WPT) technologies in terms of degrees of freedom, thus advancing the development and application of WPT technologies. Accurate mutual inductance identification is essential for establishing and optimizing paths in WPTN systems. However, the dynamic nature of the network causes frequent changes in mutual inductance parameters as nodes join or leave. This makes traditional calculation methods inadequate for complex multinode network. To address this challenge, this article proposes a dynamic mutual inductance identification method based on the gradient descent algorithm. The method effectively handles simultaneous changes in multiple mutual inductance parameters caused by network topology variations. By constructing a mathematical model of the WPTN system and designing a gradient descent algorithm with adaptive learning rates, the method achieves synchronous identification of multiple mutual inductance parameters. It does not require pretraining or extensive computational resources, and supports both online and offline identification. Experimental results on a four-node system platform show that the proposed method can identify three new mutual inductances in real time during node switching, while dynamically selecting the most efficient transmission path.
- 1 September 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 41 (1) , 1475-1489
Fixed-Frequency Parity-Time Symmetric Operation Using a Dual-Side Active Tuning Method for Wireless Power Transfer Systems
In conventional parity-time (PT)-symmetric wireless power transfer systems, capacitance drift, an unavoidable factor in practical applications, can induce detuning between the transmitter (Tx) and receiver (Rx), thereby degrading system performance. In addition, significant frequency variations arising from the frequency-dependent nonlinear saturation gain can lead to regulatory noncompliance and complicate filter design. This article proposes a simple dual-side active tuning method to achieve fixed-frequency PT-symmetric operation. Synchronous series compensators are introduced to ensure balanced energy distribution between the Tx and Rx. Active matching adjustment is required only on the Rx-side compensator, whereas the Tx-side compensator self-adjusts automatically. Theoretical analysis indicates that both the output voltage and transfer efficiency remain robust against variations in compensation capacitance, self-inductance, coupling coefficient, and load. Moreover, a parallel inductor at the inverter output achieves zero-voltage switching across the entire operating range. Experimental results demonstrate that the system maintains a constant output voltage across a wide coupling coefficient range (0.109–0.518), even with over 14% variation in compensation capacitance and 10.68% variation in self-inductance.
- 1 September 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 41 (1) , 1475-1489
Fixed-Frequency Parity-Time Symmetric Operation Using a Dual-Side Active Tuning Method for Wireless Power Transfer Systems
In conventional parity-time (PT)-symmetric wireless power transfer systems, capacitance drift, an unavoidable factor in practical applications, can induce detuning between the transmitter (Tx) and receiver (Rx), thereby degrading system performance. In addition, significant frequency variations arising from the frequency-dependent nonlinear saturation gain can lead to regulatory noncompliance and complicate filter design. This article proposes a simple dual-side active tuning method to achieve fixed-frequency PT-symmetric operation. Synchronous series compensators are introduced to ensure balanced energy distribution between the Tx and Rx. Active matching adjustment is required only on the Rx-side compensator, whereas the Tx-side compensator self-adjusts automatically. Theoretical analysis indicates that both the output voltage and transfer efficiency remain robust against variations in compensation capacitance, self-inductance, coupling coefficient, and load. Moreover, a parallel inductor at the inverter output achieves zero-voltage switching across the entire operating range. Experimental results demonstrate that the system maintains a constant output voltage across a wide coupling coefficient range (0.109–0.518), even with over 14% variation in compensation capacitance and 10.68% variation in self-inductance.
- 26 February 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 40 (7) , 10221-10241
A Data-Driven Control Method for Nonlinear Characteristics of Variable Frequency Regulation for Wide-Distance-Range Adaptive WPT System
In the realm of output control for wireless power transfer (WPT) systems, variable frequency (VF) regulation of the transmitter inverter stands out as a leading and sophisticated research direction, as it facilitates the adjustment of the voltage conversion ratio and holds significant promise for long-distance power transfer applications. However, the VF regulation process in WPT systems is characterized by strong nonlinearity and is highly sensitive to variations in the inverter driving frequency. In addition, increasing transfer distances exacerbate these nonlinearities due to changing mutual inductances. Consequently, traditional approaches to VF regulation are constrained by a limited operating range, which impedes the application of WPT technology in scenarios involving varying distances. To address these challenges and enhance the system's adaptability to different power transmission distances while managing multiparametric uncertainties in WPT systems, this article develops a data-driven model-free adaptive control (MFAC) method. Initially, an online modeling approach utilizing dynamic linearization is proposed to characterize the VF regulation process using solely system input–output data. Subsequently, a switched control strategy based on the estimated data model is devised to calculate the optimal operating frequency for the WPT system. Finally, a prototype with maximum output of 3.88 kW is constructed to demonstrate the feasibility of the proposed approach. The results indicate that the data-driven control system exhibits a robust dynamic response and strong resilience across varying transfer distances ranging from 5 to 65 cm, corresponding to a distance–diameter ratio of 0.125–1.625.
- 26 February 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 40 (7) , 10221-10241
A Data-Driven Control Method for Nonlinear Characteristics of Variable Frequency Regulation for Wide-Distance-Range Adaptive WPT System
In the realm of output control for wireless power transfer (WPT) systems, variable frequency (VF) regulation of the transmitter inverter stands out as a leading and sophisticated research direction, as it facilitates the adjustment of the voltage conversion ratio and holds significant promise for long-distance power transfer applications. However, the VF regulation process in WPT systems is characterized by strong nonlinearity and is highly sensitive to variations in the inverter driving frequency. In addition, increasing transfer distances exacerbate these nonlinearities due to changing mutual inductances. Consequently, traditional approaches to VF regulation are constrained by a limited operating range, which impedes the application of WPT technology in scenarios involving varying distances. To address these challenges and enhance the system's adaptability to different power transmission distances while managing multiparametric uncertainties in WPT systems, this article develops a data-driven model-free adaptive control (MFAC) method. Initially, an online modeling approach utilizing dynamic linearization is proposed to characterize the VF regulation process using solely system input–output data. Subsequently, a switched control strategy based on the estimated data model is devised to calculate the optimal operating frequency for the WPT system. Finally, a prototype with maximum output of 3.88 kW is constructed to demonstrate the feasibility of the proposed approach. The results indicate that the data-driven control system exhibits a robust dynamic response and strong resilience across varying transfer distances ranging from 5 to 65 cm, corresponding to a distance–diameter ratio of 0.125–1.625.