GHGaofa He

Gaofa He

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Gaofa He has a total of 15 co-authors. Here are the top co-authors by number of shared publications:

  • Zhong Lin Wang

    Beijing Institute of Nanoenergy and Nanosystems, Chinese Academy of Sciences, Beijing, China

    2 shared publications
  • Jie Meng

    School of Mechanical and Power Engineering , Chongqing University of Science and Technology , Chongqing 401331 , China

    1 shared publication
  • Jing You

    Institute for Superconducting and Electronic Materials Australian Institute for Innovative Materials University of Wollongong Wollongong New South Wales Australia

    1 shared publication
  • Kai Wei

    School of Mechanical and Power Engineering Chongqing University of Science & Technology Chongqing 401331 China

    1 shared publication
  • Lian Shen

    School of Mechanical and Power Engineering Chongqing University of Science & Technology Chongqing 401331 China

    1 shared publication
  • Peng Zhong

    School of Mechanical and Power Engineering , Chongqing University of Science and Technology , Chongqing 401331 , China

    1 shared publication

Latest Publications

  • Highly Robust Self‐Switching Mode Triboelectric Nanogenerator Based on Misaligned Triple‐Cam Design

    by Gaofa He, Kai Wei, Rui Lu, Yuhang Zhang, Lian Shen, Zhong Lin Wang, Ying Wu

    To enhance the robustness and lifespan of triboelectric nanogenerator (TENG) and facilitate its industrial applications, herein, a self‐switching mode TENG that combines the advantages of contact mode and noncontact mode TENG is presented. Noncontact mode TENG prevents material wear but generates insufficient power, whereas contact enhances power generation by increasing the charge density on the electrode surface. The proposed device can automatically switch between contact and noncontact modes through a triple‐cam mechanism and gear train deceleration mechanism. Experimental results determine the optimal force value of 6 N and corresponding cam height of 1 mm, contact time of 8 min, and noncontact time of 30 min, to ensure good power output and minimal material wear. Simulation results demonstrate that the three cams have more stable mechanical properties and can improve the device's robustness. The cam repose angle and gear train structure are optimized based on the curves of electrical output versus time for both modes, and a method is proposed to extend the self‐switching time. The self‐switching mode TENG has a longer life than the other two modes, with its transfer charge maintaining 90% of its initial value after 80 h of continuous operation.


  • Open Access

    Electrostatic Force Microscopy Measurement System for Micro-topography of Non-conductive Devices

    by Gaofa He, Jie Meng, Renbing Tan, Peng Zhong

    A home-made electrostatic force microscopy (EFM) system is described which is directed toward assessment of the microscopic geometry of the surface of specimens made of non-conductive material with a large thickness. This system is based on the variation in the electrostatic force between the conductive probe and the non-conductive specimen in order to get its surface morphology. First, based on the principle of dielectric polarization, the variation rules of the electrostatic force between the charged probe and the non-conductive specimen were studied. Later, a special tuning fork resonant probe unit made of quartz crystal was fabricated for measurement of the electrostatic force, and the scanning probe microscopic system in the constant force mode was constructed to characterize the three-dimensional micro-topography of the surface of the specimen. Finally, this system was used to perform scanning measurement experiments on the indented surface of the specimen made of the polyvinyl chloride (PVC) material with thickness 3 mm. In the present experimental system, when the external voltage was 100 V and the distance from the probe tip to the specimen surface approximately 100 nm, the variance in the resonant frequency of the probe unit was around 0.5 Hz. These results indicate that this home-made EFM system can effectively characterize the micro-topography of the non-conductive specimen with very large thickness which is above several millimeters.