ISIuliia A. Sadykova

Iuliia A. Sadykova

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Iuliia A. Sadykova has a total of 60 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Rational experimental-computational correlation of residual strain simulation in an AA2024-T4 plate with time-of-flight neutron diffraction

    by Eugene S. Statnik, Igor A. Zorin, Igor V. Papushkin, Iuliia A. Sadykova, Alexey I. Salimon, Gizo D. Bokuchava, Alexander M. Korsunsky

  • Selection of rational exposure modes for acrylic dental materials in a carbon dioxide environment to reduce the release of residual methyl methacrylate

    by Y.N. Kharakh, A.I. Salimon, S.V. Stakhanova, Iu.A. Sadykova, N.V. Mikhailova, V.P. Chuev, S.D. Arutyunov

    Residual methyl methacrylate (MMA) retained in dental polymethyl methacrylate (PMMA) after polymerization can migrate into liquid media and is considered a potential contributor to adverse tissue reactions. The aim of this study was to determine CO₂ exposure regimes for heat- and cold-cured dental PMMA that reduce subsequent MMA release into aqueous extracts while monitoring surface roughness, dimensional stability, and flexural properties of the material. Materials and methods. Heat-cured and cold-cured PMMA samples (“Belakril-M GO” and “Belakril-M HO”, VladMiVa, Russia) were exposed to CO₂ under varied temperature (20—45°C), pressure (50—100 atm), and exposure time (10—30 min) according to a central composite design. The primary response was the change in mass-normalized MMA concentration in aqueous extracts (ΔC), determined by micellar electrokinetic chromatography. Surface roughness (Ra, Rz), dimensional change (ΔG), and flexural properties under three-point bending, including flexural modulus (E), flexural strength (σf), and maximum deflection (δ), were used as control responses. The regimes were selected using response surface models and then tested in an independent validation series with 10 runs for each material. Results. For cold-cured PMMA, the model-derived and experimentally validated regime was 22.5°C, 61.1 atm, and 10 min, reducing mass-normalized MMA concentration from 3.018 to 1.697 μg/mL, corresponding to a 43.8% decrease (p<0.01). For heat-cured PMMA, the selected regime of 32.3°C, 105 atm, and 30 min reduced this parameter from 1.036 to 0.414 μg/mL, corresponding to a 60% decrease (p<0.001). No statistically significant changes in Ra, Rz, or dimensional parameters were detected for either material. At the same time, both materials showed an increase in flexural modulus accompanied by decreases in flexural strength and maximum deflection. Conclusions. Model-guided CO₂ exposure can reduce subsequent MMA release from heat- and cold-cured dental PMMA into aqueous extracts without detectable changes in surface roughness or dimensional stability under the studied conditions. However, the accompanying shift in flexural behavior indicates that further optimization should account not only for the chemical effect but also for preservation of the mechanical performance of the material.

  • Rational experimental-computational correlation analysis of cross-sectioning methods for residual stress evaluation

    by Igor A. Zorin, Konstantin S. Korobov, Alexander A. Frantsuzov, Andrey I. Shtypel, Iuliia A. Sadykova, Eugene S. Statnik, Alexey I. Salimon, Alexander M. Korsunsky


  • Residual monomer release dynamics in heat- and cold-cured dental polymethyl methacrylates: a pilot study

    by Ya.N. Kharakh, L.V. Dubova, O.I. Manin, S.V. Stakhanova, N.V. Mikhailova, A.I. Salimon, I.A. Zorin, Iu.A. Sadykova, E.S. Statnik, A.M. Korsunsky, et al.

    Residual methyl methacrylate (MMA) in polymethyl methacrylate (PMMA) is a risk factor in removable prostheses due to its potential cytotoxicity. Objective. To assess the release dynamics of MMA from domestically produced heat- and cold-cured PMMA samples during the first 10 days post-polymerization. Materials and methods. Standardized specimens (10×10×4 mm) were fabricated from heat-cured PMMA and cold-cured PMMA. Samples were stored in deionized water at 37°C, and the MMA concentration in the eluates was measured on days 1, 3, 6, and 10 by micellar electrokinetic capillary chromatography. Results. In the heat-cured group, the mean MMA concentration ranged from 0.237 to 0.641 µg/mL (p=0.480), while in the cold-cured group it ranged from 0.796 to 5.443 µg/mL (p=0.109). No statistically significant changes in MMA levels were observed over the monitoring period (p> 0.05). Conclusions. Under the conditions tested—storage in deionized water for up to 10 days—the storage duration does not affect the residual monomer content in PMMA. These findings are important for developing PMMA post-curing protocols prior to clinical application.

  • Open Access

    Dynamic Damage Analysis of Carbon Fiber Reinforced Polymer Composite Confinement Vessels

    by Kamal M. Hammad, Iuliia A. Sadykova, Eugene N. Prokopev, Galina V. Tyurina, Semen D. Ignatyev, Eugene S. Statnik

    This study investigates spall damage and failure in Carbon Fiber-Reinforced Polymer (CFRP) pressure vessels under explosive internal loading using stimulated electric discharge. Analytical modeling, validation with published experimental data, and explicit numerical simulations were employed. A Coupled Eulerian–Lagrangian (CEL) framework in Abaqus/Explicit captured the dynamic-impact shock propagation, using continuum shell (SC8R) elements for the vessel, solid (C3D8R) for the PMMA insert, and Eulerian (EC3D8R) for copper-wire vapor. Intralaminar failure was modeled using the Hashin criterion, while interlaminar damage was captured using the energy-release-rate-tuned Virtual Crack Closure Technique (VCCT). Results demonstrated high-accuracy agreement with experiments in terms of free surface velocity and failure stresses, with minor discrepancies attributed to wire alignment, material model limitations, and wave reverberations. These findings highlight the reliability of the integrated modeling framework and support improved design and risk-mitigation strategies for composite pressure vessels, advancing safety and cost-efficiency through refined material characterization and structural assessment.


  • Open Access

    Parameters Optimization for Manufacturing Advanced Self-Reinforced Composites based on Ultra-High Molecular Weight Polyethylene

    by Eugene Statnik, Dmitry D. Zherebtsov, Dilus I. Chukov, Ilya I. Larin, Alnis A. Veveris, Valerii G. Torokhov, Alexander S. Kechekyan, Kristina Z. Myagkova, Iuliia A. Sadykova, Alexey I. Salimon, et al.

    In this study, the relationships between processing, structure and properties of self-reinforced ultra-high molecular weight polyethylene (UHMWPE) composites fabricated via thermal pressing are investigated. By systematically varying processing temperatures (145, 155, 165, 170, 175,180 °C) and pressures (25 and 50 MPa), we demonstrate that mechanical performance is governed by the interplay between fiber consolidation and the preservation of the oriented crystalline phase. Scanning electron microscopy reveals the presence of residual voids that are independent of the processing parameters, and which lead to interfacial failure and fibrillar fracture morphologies. We identify a critical processing threshold at 165 °C (25 MPa), which yields peak interlayer shear strength (7.8–11.1 MPa), bending strength (102–130 MPa), elastic modulus (23–42 GPa), and Charpy impact resistance (72–95 kJ/m²). Beyond this threshold, however, mechanical performance deteriorates due to fiber remelting and loss of anisotropy, resulting in the composite transitioning to an isotropic UHMWPE matrix. Conversely, elevated pressures fail to improve properties due to insufficient macromolecular interdiffusion, which is the dominant bonding mechanism. These findings establish a processing-structure-property framework for UHMWPE-based self-reinforced composites that balances interfacial adhesion and crystalline alignment, while providing actionable guidelines for engineering high-performance single-polymer materials.

  • Realization of the shape memory effect in a composite material PLA/Diopside with different supramolecular structures

    by Polina Kovaleva, Inna Bulygina, Anna Cheremnykh, Eugene Statnik, Ekaterina Ivantsova, Iuliia Sadykova, Mikhail Zadorozhnyy, Artem Korol, Fedor Senatov


  • Open Access

    High strength and ductility in a new Mg–Zn–Ga biocompatible alloy by drawing and rotary forging

    by Stanislav O. Rogachev, Viacheslav E. Bazhenov, Alexander A. Komissarov, Denis V. Ten, Anna V. Li, Vladimir A. Andreev, Eugene S. Statnik, Iuliia A. Sadykova, Sofia V. Plegunova, Viacheslav V. Yushchuk, et al.


  • Open Access

    An In Vivo Rat Study of Bioresorbable Mg-2Zn-2Ga Alloy Implants

    by Alexey Drobyshev, Zaira Gurganchova, Nikolay Redko, Alexander Komissarov, Viacheslav Bazhenov, Eugene S. Statnik, Iuliia A. Sadykova, Eugeny Sviridov, Alexey I. Salimon, Alexander M. Korsunsky, et al.

    In the present study, pins made from the novel Mg-2Zn-2Ga alloy were installed within the femoral bones of six Wistar rats. The level of bioresorption was assessed after 1, 3, and 6 months by radiography, histology, SEM, and EDX. Significant bioresorption was evident after 3 months, and complete dissolution of the pins occurred at 6 months after the installation. No pronounced gas cavities could be found at the pin installation sites throughout the postoperative period. The animals’ blood parameters showed no signs of inflammation or toxication. These findings are sufficiently encouraging to motivate further research to broaden the experimental coverage to increase the number of observed animals and to conduct tests involving other, larger animals.