Chiara Zanetti
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Chiara Zanetti has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Anita Rose Maguire
School of Chemistry, University College Cork, College Road, Cork T12 YN60, Ireland
1 shared publication - Dmitri Papkovsky
School of Biochemistry and Cell Biology, University College Cork, Cavanagh Pharmacy Building, College Road, T12 YT20 Cork, Ireland
1 shared publication - Elisa Santovito
Institute of Sciences of Food Production, National Research Council of Italy (CNR-ISPA), Via Amendola 122/O, 70125 Bari, Italy
1 shared publication - Liang Li
School of Biochemistry and Cell Biology, University College Cork, Pharmacy Building, College Road, T12 K8AF Cork, Ireland
1 shared publication - Rafael Di Lazaro Gaspar
Cell Analysis Division, Agilent Inc., Euro House, Little Island, T45 WK12 Cork, Ireland
1 shared publication - Sophia Elisseeva
School of Biochemistry and Cell Biology, University College Cork, Pharmacy Building, College Road, T12 K8AF Cork, Ireland
1 shared publication
Latest Publications
- Open Access
Susceptibility of the Different Oxygen-Sensing Probes to Interferences in Respirometric Bacterial Assays with Complex Media
Respirometric microbial assays are gaining popularity, but their uptake is limited by the availability of optimal O2 sensing materials and the challenge of validating assays with complex real samples. We conducted a comparative evaluation of four different O2-sensing probes based on Pt-porphyrin phosphors in respirometric bacterial assays performed on standard time-resolved fluorescence reader. The macromolecular MitoXpress, nanoparticle NanO2 and small molecule PtGlc4 and PtPEG4 probes were assessed with E. coli cells in five growth media: nutrient broth (NB), McConkey (MC), Rapid Coliform ChromoSelect (RCC), M-Lauryl lauryl sulfate (MLS), and Minerals-Modified Glutamate (MMG) media. Respiration profiles of the cells were recorded and analyzed, along with densitometry profiles and quenching studies of individual media components. This revealed several limiting factors and interferences impacting assay performance, which include probe quenched lifetime, instrument temporal resolution, inner filter effects (mainly by indicator dyes), probe binding to lipophilic components, and dynamic and static quenching by media components. The study allowed for the ranking of the probes based on their ruggedness, resilience to interferences and overall performance in respirometric bacterial assays. The ‘shielded’ probe NanO2 outperformed the established MitoXpress probe and the small molecule probes PtGlc4 and PtPEG4.
Open AccessSusceptibility of the Different Oxygen-Sensing Probes to Interferences in Respirometric Bacterial Assays with Complex Media
Respirometric microbial assays are gaining popularity, but their uptake is limited by the availability of optimal O2 sensing materials and the challenge of validating assays with complex real samples. We conducted a comparative evaluation of four different O2-sensing probes based on Pt-porphyrin phosphors in respirometric bacterial assays performed on standard time-resolved fluorescence reader. The macromolecular MitoXpress, nanoparticle NanO2 and small molecule PtGlc4 and PtPEG4 probes were assessed with E. coli cells in five growth media: nutrient broth (NB), McConkey (MC), Rapid Coliform ChromoSelect (RCC), M-Lauryl lauryl sulfate (MLS), and Minerals-Modified Glutamate (MMG) media. Respiration profiles of the cells were recorded and analyzed, along with densitometry profiles and quenching studies of individual media components. This revealed several limiting factors and interferences impacting assay performance, which include probe quenched lifetime, instrument temporal resolution, inner filter effects (mainly by indicator dyes), probe binding to lipophilic components, and dynamic and static quenching by media components. The study allowed for the ranking of the probes based on their ruggedness, resilience to interferences and overall performance in respirometric bacterial assays. The ‘shielded’ probe NanO2 outperformed the established MitoXpress probe and the small molecule probes PtGlc4 and PtPEG4.