Brandon Lu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Brandon Lu has a total of 65 co-authors. Here are the top co-authors by number of shared publications:
- Jianping Xia
Thomas Lord Department of Mechanical Engineering and Materials Science, Duke University, Durham, NC 27708, USA
4 shared publications - Tony Jun Huang
Thomas Lord Department of Mechanical Engineering and Materials Science, Duke University, Durham, NC 27708, USA
4 shared publications - Joseph Rich
Department of Biomedical Engineering, Duke University, Durham, USA
2 shared publications - Luke P. Lee
Renal Division and Division of Engineering in Medicine, Department of Medicine, Brigham and Women’s Hospital, Harvard Medical School, Boston, MA, USA
2 shared publications - Shujie Yang
Thomas Lord Department of Mechanical Engineering and Materials Science, Duke University, Durham, NC 27708, USA
2 shared publications - Zhenhua Tian
Department of Mechanical Engineering Virginia Polytechnic Institute and State University Blacksburg Virginia USA
2 shared publications
Latest Publications
- Open Access
- 5 September 2025
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 11 (36) , eady3262
Acoustofluidic system for targeted antibody removal in transplantation: Enabling small-volume therapeutic apheresis
Antibody-mediated rejection is a leading cause of allograft failure and mortality in pediatric solid organ transplant recipients. Current apheresis systems require large blood volumes and are primarily designed for adults, making them unsuitable for children and small animals. These systems often indiscriminately remove both harmful and protective antibodies, increasing the risk of complications such as life-threatening infections. To address this critical need, we developed acoustofluidic-based system for targeted antibody removal in transplantation (A-START). A-START is engineered to handle small blood volumes and has demonstrated efficacy in preclinical small animal trials. In a sensitized rodent skin transplantation model, A-START only demands 240 microliters of blood, selectively removing donor-specific alloantibodies (DSAs) while preserving protective antibodies, such as tetanus antibodies. A-START retains ~95% of beneficial antibodies and achieves a 60% improvement in DSA removal compared to conventional methods. These findings highlight the transformative potential of A-START as a promising, reliable, scalable solution for improving outcomes in pediatric transplantation and treating antibody-mediated diseases.
- 5 September 2025
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 11 (36) , eady3262
Open AccessAcoustofluidic system for targeted antibody removal in transplantation: Enabling small-volume therapeutic apheresis
Antibody-mediated rejection is a leading cause of allograft failure and mortality in pediatric solid organ transplant recipients. Current apheresis systems require large blood volumes and are primarily designed for adults, making them unsuitable for children and small animals. These systems often indiscriminately remove both harmful and protective antibodies, increasing the risk of complications such as life-threatening infections. To address this critical need, we developed acoustofluidic-based system for targeted antibody removal in transplantation (A-START). A-START is engineered to handle small blood volumes and has demonstrated efficacy in preclinical small animal trials. In a sensitized rodent skin transplantation model, A-START only demands 240 microliters of blood, selectively removing donor-specific alloantibodies (DSAs) while preserving protective antibodies, such as tetanus antibodies. A-START retains ~95% of beneficial antibodies and achieves a 60% improvement in DSA removal compared to conventional methods. These findings highlight the transformative potential of A-START as a promising, reliable, scalable solution for improving outcomes in pediatric transplantation and treating antibody-mediated diseases.
- Open Access
- 9 August 2024
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 10 (32) , eado8992
Acousto-dielectric tweezers enable independent manipulation of multiple particles
Acoustic tweezers have gained substantial interest in biology, engineering, and materials science for their label-free, precise, contactless, and programmable manipulation of small objects. However, acoustic tweezers cannot independently manipulate multiple microparticles simultaneously. This study introduces acousto-dielectric tweezers capable of independently manipulating multiple microparticles and precise control over intercellular distances and cyclical cell pairing and separation for detailed cell-cell interaction analysis. Our acousto-dielectric tweezers leverage the competition between acoustic radiation forces, generated by standing surface acoustic waves (SAWs), and dielectrophoretic (DEP) forces, induced by gradient electric fields. Modulating these fields allows for the precise positioning of individual microparticles at points where acoustic radiation and DEP forces are in equilibrium. This mechanism enables the simultaneous movement of multiple microparticles along specified paths as well as cyclical cell pairing and separation. We anticipate our acousto-dielectric tweezers to have enormous potential in colloidal assembly, cell-cell interaction studies, disease diagnostics, and tissue engineering.
- 9 August 2024
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 10 (32) , eado8992
Open AccessAcousto-dielectric tweezers enable independent manipulation of multiple particles
Acoustic tweezers have gained substantial interest in biology, engineering, and materials science for their label-free, precise, contactless, and programmable manipulation of small objects. However, acoustic tweezers cannot independently manipulate multiple microparticles simultaneously. This study introduces acousto-dielectric tweezers capable of independently manipulating multiple microparticles and precise control over intercellular distances and cyclical cell pairing and separation for detailed cell-cell interaction analysis. Our acousto-dielectric tweezers leverage the competition between acoustic radiation forces, generated by standing surface acoustic waves (SAWs), and dielectrophoretic (DEP) forces, induced by gradient electric fields. Modulating these fields allows for the precise positioning of individual microparticles at points where acoustic radiation and DEP forces are in equilibrium. This mechanism enables the simultaneous movement of multiple microparticles along specified paths as well as cyclical cell pairing and separation. We anticipate our acousto-dielectric tweezers to have enormous potential in colloidal assembly, cell-cell interaction studies, disease diagnostics, and tissue engineering.
- 16 July 2024
- Published by Wolters Kluwer Health in Journal of the American Society of Nephrology
- Vol. 35 (11) , 1507-1519
Renovascular Disease and Mitochondrial Dysfunction in Human Mesenchymal Stem Cells
Key Points: Renovascular disease impairs the capacity of human adipose tissue–derived mesenchymal stem/stromal cells to repair ischemic murine kidneys. miR-378h modulated the capacity of renovascular disease adipose tissue–derived mesenchymal stem/stromal cells to repair ischemic kidneys in vivo. Background: Renovascular disease leads to renal ischemia, hypertension, and eventual kidney failure. Autologous transplantation of adipose tissue–derived mesenchymal stem/stromal cells (MSCs) improves perfusion and oxygenation in stenotic human kidneys, but associated atherosclerosis and hypertension might blunt their effectiveness. We hypothesized that renovascular disease alters the human MSC transcriptome and impairs their reparative potency. Methods: MSCs were harvested from subcutaneous abdominal fat of patients with renovascular disease and healthy volunteers (n=3 each), characterized and subsequently injected (5×105/200 μl) into mice 2 weeks after renal artery stenosis or sham surgery (n=6/group). Two weeks later, mice underwent imaging and tissue studies. MSCs from healthy volunteers and in those with renovascular disease were also characterized by mRNA/microRNA (miRNA) sequencing. Based on these, MSC proliferation and mitochondrial damage were assessed in vitro before and after miRNA modulation and in vivo in additional renal artery stenosis mice administered with MSCs from renovascular disease pretreated with miR-378h mimic (n=5) or inhibitor (n=4). Results: MSCs engrafted in stenotic mouse kidneys. Healthy volunteer MSCs (but not renovascular disease MSCs) decreased BP, improved serum creatinine levels and stenotic-kidney cortical perfusion and oxygenation, and attenuated peritubular capillary loss, tubular injury, and fibrosis. Genes upregulated in renovascular disease MSCs versus healthy volunteer MSCs were mostly implicated in transcription and cell proliferation, whereas those downregulated encoded mainly mitochondrial proteins. Upregulated miRNAs, including miR-378h, primarily target nuclear-encoded mitochondrial genes, whereas downregulated miRNAs mainly target genes implicated in transcription and cell proliferation. MSC proliferation was similar, but their mitochondrial structure and reparative function both in vivo and in vitro improved after miR-378h inhibition. Conclusions: Renovascular disease impaired the reparative capacity of human MSCs, possibly by dysregulating miR-378h that targets mitochondrial genes. Podcast: This article contains a podcast at https://dts.podtrac.com/redirect.mp3/www.asn-online.org/media/podcast/JASN/2024_08_21_ASN0000000000000440.mp3
- 16 July 2024
- Published by Wolters Kluwer Health in Journal of the American Society of Nephrology
- Vol. 35 (11) , 1507-1519
Renovascular Disease and Mitochondrial Dysfunction in Human Mesenchymal Stem Cells
Key Points: Renovascular disease impairs the capacity of human adipose tissue–derived mesenchymal stem/stromal cells to repair ischemic murine kidneys. miR-378h modulated the capacity of renovascular disease adipose tissue–derived mesenchymal stem/stromal cells to repair ischemic kidneys in vivo. Background: Renovascular disease leads to renal ischemia, hypertension, and eventual kidney failure. Autologous transplantation of adipose tissue–derived mesenchymal stem/stromal cells (MSCs) improves perfusion and oxygenation in stenotic human kidneys, but associated atherosclerosis and hypertension might blunt their effectiveness. We hypothesized that renovascular disease alters the human MSC transcriptome and impairs their reparative potency. Methods: MSCs were harvested from subcutaneous abdominal fat of patients with renovascular disease and healthy volunteers (n=3 each), characterized and subsequently injected (5×105/200 μl) into mice 2 weeks after renal artery stenosis or sham surgery (n=6/group). Two weeks later, mice underwent imaging and tissue studies. MSCs from healthy volunteers and in those with renovascular disease were also characterized by mRNA/microRNA (miRNA) sequencing. Based on these, MSC proliferation and mitochondrial damage were assessed in vitro before and after miRNA modulation and in vivo in additional renal artery stenosis mice administered with MSCs from renovascular disease pretreated with miR-378h mimic (n=5) or inhibitor (n=4). Results: MSCs engrafted in stenotic mouse kidneys. Healthy volunteer MSCs (but not renovascular disease MSCs) decreased BP, improved serum creatinine levels and stenotic-kidney cortical perfusion and oxygenation, and attenuated peritubular capillary loss, tubular injury, and fibrosis. Genes upregulated in renovascular disease MSCs versus healthy volunteer MSCs were mostly implicated in transcription and cell proliferation, whereas those downregulated encoded mainly mitochondrial proteins. Upregulated miRNAs, including miR-378h, primarily target nuclear-encoded mitochondrial genes, whereas downregulated miRNAs mainly target genes implicated in transcription and cell proliferation. MSC proliferation was similar, but their mitochondrial structure and reparative function both in vivo and in vitro improved after miR-378h inhibition. Conclusions: Renovascular disease impaired the reparative capacity of human MSCs, possibly by dysregulating miR-378h that targets mitochondrial genes. Podcast: This article contains a podcast at https://dts.podtrac.com/redirect.mp3/www.asn-online.org/media/podcast/JASN/2024_08_21_ASN0000000000000440.mp3
- 8 March 2024
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 10 (10) , eadm8597
Acoustic separation and concentration of exosomes for nucleotide detection: ASCENDx
Efficient isolation and analysis of exosomal biomarkers hold transformative potential in biomedical applications. However, current methods are prone to contamination and require costly consumables, expensive equipment, and skilled personnel. Here, we introduce an innovative spaceship-like disc that allows Acoustic Separation and Concentration of Exosomes and Nucleotide Detection: ASCENDx. We created ASCENDx to use acoustically driven disc rotation on a spinning droplet to generate swift separation and concentration of exosomes from patient plasma samples. Integrated plasmonic nanostars on the ASCENDx disc enable label-free detection of enriched exosomes via surface-enhanced Raman scattering. Direct detection of circulating exosomal microRNA biomarkers from patient plasma samples by the ASCENDx platform facilitated a diagnostic assay for colorectal cancer with 95.8% sensitivity and 100% specificity. ASCENDx overcomes existing limitations in exosome-based molecular diagnostics and holds a powerful position for future biomedical research, precision medicine, and point-of-care medical diagnostics.
- 8 March 2024
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 10 (10) , eadm8597
Acoustic separation and concentration of exosomes for nucleotide detection: ASCENDx
Efficient isolation and analysis of exosomal biomarkers hold transformative potential in biomedical applications. However, current methods are prone to contamination and require costly consumables, expensive equipment, and skilled personnel. Here, we introduce an innovative spaceship-like disc that allows Acoustic Separation and Concentration of Exosomes and Nucleotide Detection: ASCENDx. We created ASCENDx to use acoustically driven disc rotation on a spinning droplet to generate swift separation and concentration of exosomes from patient plasma samples. Integrated plasmonic nanostars on the ASCENDx disc enable label-free detection of enriched exosomes via surface-enhanced Raman scattering. Direct detection of circulating exosomal microRNA biomarkers from patient plasma samples by the ASCENDx platform facilitated a diagnostic assay for colorectal cancer with 95.8% sensitivity and 100% specificity. ASCENDx overcomes existing limitations in exosome-based molecular diagnostics and holds a powerful position for future biomedical research, precision medicine, and point-of-care medical diagnostics.
- Open Access
- 1 January 2024
- Published by Springer Nature in Microsystems & Nanoengineering
- Vol. 10 (1) , 1-12
Aerosol jet printing of surface acoustic wave microfluidic devices
The addition of surface acoustic wave (SAW) technologies to microfluidics has greatly advanced lab-on-a-chip applications due to their unique and powerful attributes, including high-precision manipulation, versatility, integrability, biocompatibility, contactless nature, and rapid actuation. However, the development of SAW microfluidic devices is limited by complex and time-consuming micro/nanofabrication techniques and access to cleanroom facilities for multistep photolithography and vacuum-based processing. To simplify the fabrication of SAW microfluidic devices with customizable dimensions and functions, we utilized the additive manufacturing technique of aerosol jet printing. We successfully fabricated customized SAW microfluidic devices of varying materials, including silver nanowires, graphene, and poly(3,4-ethylenedioxythiophene) polystyrene sulfonate (PEDOT:PSS). To characterize and compare the acoustic actuation performance of these aerosol jet printed SAW microfluidic devices with their cleanroom-fabricated counterparts, the wave displacements and resonant frequencies of the different fabricated devices were directly measured through scanning laser Doppler vibrometry. Finally, to exhibit the capability of the aerosol jet printed devices for lab-on-a-chip applications, we successfully conducted acoustic streaming and particle concentration experiments. Overall, we demonstrated a novel solution-based, direct-write, single-step, cleanroom-free additive manufacturing technique to rapidly develop SAW microfluidic devices that shows viability for applications in the fields of biology, chemistry, engineering, and medicine.
- 1 January 2024
- Published by Springer Nature in Microsystems & Nanoengineering
- Vol. 10 (1) , 1-12
Open AccessAerosol jet printing of surface acoustic wave microfluidic devices
The addition of surface acoustic wave (SAW) technologies to microfluidics has greatly advanced lab-on-a-chip applications due to their unique and powerful attributes, including high-precision manipulation, versatility, integrability, biocompatibility, contactless nature, and rapid actuation. However, the development of SAW microfluidic devices is limited by complex and time-consuming micro/nanofabrication techniques and access to cleanroom facilities for multistep photolithography and vacuum-based processing. To simplify the fabrication of SAW microfluidic devices with customizable dimensions and functions, we utilized the additive manufacturing technique of aerosol jet printing. We successfully fabricated customized SAW microfluidic devices of varying materials, including silver nanowires, graphene, and poly(3,4-ethylenedioxythiophene) polystyrene sulfonate (PEDOT:PSS). To characterize and compare the acoustic actuation performance of these aerosol jet printed SAW microfluidic devices with their cleanroom-fabricated counterparts, the wave displacements and resonant frequencies of the different fabricated devices were directly measured through scanning laser Doppler vibrometry. Finally, to exhibit the capability of the aerosol jet printed devices for lab-on-a-chip applications, we successfully conducted acoustic streaming and particle concentration experiments. Overall, we demonstrated a novel solution-based, direct-write, single-step, cleanroom-free additive manufacturing technique to rapidly develop SAW microfluidic devices that shows viability for applications in the fields of biology, chemistry, engineering, and medicine.