Yan Wang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Yan Wang has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Xiaoqiang Guo
Yanshan University
2 shared publications - Jihu Fan
Key Laboratory of Power Electronics for Energy Conservation and Motor Drive of Hebei Province, Department of Electrical Engineering, Yanshan University, Qinhuangdao, China
1 shared publication - Naizhe Diao
Yanshan University
1 shared publication - Qixing Gao
Yanshan University
1 shared publication - Xiaozhe Zhang
Key Laboratory of Power Electronics for Energy Conservation and Motor Drive of Hebei Province, Department of Electrical Engineering, Yanshan University, Qinhuangdao, China
1 shared publication
Latest Publications
- 30 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 72 (5) , 4956-4965
Startup Strategy for High Power Density Three-Phase Buck-Type PFC Rectifier
Traditional three-phase Buck-type power factor correction (PFC) rectifier typically have a large dc-side inductor, which suppresses the inrush current during startup. However, with the trend towards higher power density, the smaller inductor is often used to replace larger ones on the dc-side. This change results in a significant shift in the startup characteristics of three-phase Buck-type PFC rectifier. Currently, there is little research on startup control strategy for three-phase Buck-type PFC rectifier with high power density. To fulfill this gap, this article investigates the issue of startup inrush current of high power density three-phase Buck-type PFC rectifier. This article provides a detailed analysis of the mechanism behind inrush current generation in three-phase Buck-type PFC rectifiers with high power density. Based on this analysis, a soft-startup scheme and a method for designing its startup curve are proposed to achieve a rapid startup within the safety threshold. Finally, a 4kW industrial prototype is built to verify the effectiveness of the proposed scheme. The test results show that this method achieves a rapid soft startup of the system.
- 30 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 72 (5) , 4956-4965
Startup Strategy for High Power Density Three-Phase Buck-Type PFC Rectifier
Traditional three-phase Buck-type power factor correction (PFC) rectifier typically have a large dc-side inductor, which suppresses the inrush current during startup. However, with the trend towards higher power density, the smaller inductor is often used to replace larger ones on the dc-side. This change results in a significant shift in the startup characteristics of three-phase Buck-type PFC rectifier. Currently, there is little research on startup control strategy for three-phase Buck-type PFC rectifier with high power density. To fulfill this gap, this article investigates the issue of startup inrush current of high power density three-phase Buck-type PFC rectifier. This article provides a detailed analysis of the mechanism behind inrush current generation in three-phase Buck-type PFC rectifiers with high power density. Based on this analysis, a soft-startup scheme and a method for designing its startup curve are proposed to achieve a rapid startup within the safety threshold. Finally, a 4kW industrial prototype is built to verify the effectiveness of the proposed scheme. The test results show that this method achieves a rapid soft startup of the system.
- 10 November 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 39 (2) , 2458-2467
Impact of Narrow Pulse on High-Switching Frequency Three-Phase Current Source Rectifier
In this article, it is discovered that when the switching frequency increases, the current source rectifier (CSR) will suffer from a grid-side current distortion problem at the sector boundary. One of the reasons for this problem is the presence of narrow pulse at the sector boundary. To overcome this problem, a narrow pulse compensation solution is proposed. The solution attempts to alleviate the negative effects of narrow pulse from two aspects: 1) Avoiding the switch with an on -type narrow pulse in the drive signal to affect the turn- on/-off times of the corresponding bridge legs. 2) Improving the switching performance of the switch with an off -type narrow pulse in the drive signal by using a metal-oxide-semiconductor field-effect transistor with lower blocking voltage to make the actual switching characteristics closer to the ideal switching characteristics. An analysis of the generation mechanism of narrow pulse and its impact on the grid-side current is presented in this article. A 3 kW industrial prototype is also built to verify the effectiveness of the proposed solution. The test result shows that the proposed solution can effectively suppress the grid-side current distortion phenomenon, and improve the performance of CSR at high-switching frequency.
- 10 November 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 39 (2) , 2458-2467
Impact of Narrow Pulse on High-Switching Frequency Three-Phase Current Source Rectifier
In this article, it is discovered that when the switching frequency increases, the current source rectifier (CSR) will suffer from a grid-side current distortion problem at the sector boundary. One of the reasons for this problem is the presence of narrow pulse at the sector boundary. To overcome this problem, a narrow pulse compensation solution is proposed. The solution attempts to alleviate the negative effects of narrow pulse from two aspects: 1) Avoiding the switch with an on -type narrow pulse in the drive signal to affect the turn- on/-off times of the corresponding bridge legs. 2) Improving the switching performance of the switch with an off -type narrow pulse in the drive signal by using a metal-oxide-semiconductor field-effect transistor with lower blocking voltage to make the actual switching characteristics closer to the ideal switching characteristics. An analysis of the generation mechanism of narrow pulse and its impact on the grid-side current is presented in this article. A 3 kW industrial prototype is also built to verify the effectiveness of the proposed solution. The test result shows that the proposed solution can effectively suppress the grid-side current distortion phenomenon, and improve the performance of CSR at high-switching frequency.