Tanisha Martheswaran
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Tanisha Martheswaran has a total of 30 co-authors. Here are the top co-authors by number of shared publications:
- Majid Moshirfar
Hoopes Moshirfar Research Center, Hoopes Vision, Draper, UT
7 shared publications - Yasmyne Castillo Ronquillo
Hoopes Vision Research Center, Hoopes Vision, Draper, UT, USA
4 shared publications Kathryn M. Shmunes
Hoopes Vision Research Center, Hoopes Vision, Draper, UT, USA
3 shared publicationsRobert J. Thomson
McGovern Medical School at The University of Texas Health Science Center at Houston, Houston, TX
3 shared publicationsAndrew C. Thomson
McGovern Medical School at the University of Texas Health Science Center at Houston, Houston, Texas
2 shared publicationsJordan D. Desautels
The Warren Alpert Medical School of Brown University, Providence, USA
2 shared publications
Latest Publications
- Open Access
- 15 February 2022
- Published by Springer Nature in Ophthalmology and Therapy
- Vol. 11 (2) , 785-795
Refractive Outcomes After LASIK for the Treatment of Mixed Astigmatism with the Allegretto WaveLight EX500
Introduction Treatment of mixed astigmatism with laser in situ keratomileusis (LASIK) is complex as the correction requires flattening the cornea in one meridian while steepening the cornea in the other meridian. The bitoric technique has become the most popular approach and has been tested across a variety of platforms. This study is the first to evaluate the results of mixed astigmatism treatment using the Allegretto WaveLight® EX500. Methods This study was a single-center, retrospective, noncomparative analysis of 400 eyes that underwent LASIK to correct for mixed astigmatism utilizing the EX500 excimer laser. Data on uncorrected distance visual acuity, corrected distance visual acuity, and spherical equivalent was analyzed at consecutive intervals (1, 3, 6, 9, and 12 months). Refractive measurements were used to perform a vector analysis. Results Three and 12 months postoperatively, 71% and 74% of eyes had an uncorrected distance visual acuity (UDVA) of 20/20 or better and 99% and 100% of eyes had a UDVA of 20/40 or better, respectively. The postoperative UDVA was within one line of the corrected distance visual acuity (CDVA) in 88% and 93% of eyes at 3 and 12 months, respectively. At 3 months, 78% of eyes achieved refractive astigmatism no greater than 0.50 diopters and at 12 months, 80% achieved this. The mean spherical equivalent refraction was − 0.36 ± 0.57 D at 12 months after surgery. At the 12-month follow-up, the mean refractive cylinder was reduced by 87%, from − 2.79 to − 0.37 diopters. On vector analysis, 99% of eyes had an angle of error within ± 15° from the intended target at 3 and 12 months. Conclusion Treatment of mixed astigmatism using the Allegretto WaveLight® EX500 laser exceeded the industry standards of safety, efficacy, stability, and accuracy.
- 15 February 2022
- Published by Springer Nature in Ophthalmology and Therapy
- Vol. 11 (2) , 785-795
Open AccessRefractive Outcomes After LASIK for the Treatment of Mixed Astigmatism with the Allegretto WaveLight EX500
Introduction Treatment of mixed astigmatism with laser in situ keratomileusis (LASIK) is complex as the correction requires flattening the cornea in one meridian while steepening the cornea in the other meridian. The bitoric technique has become the most popular approach and has been tested across a variety of platforms. This study is the first to evaluate the results of mixed astigmatism treatment using the Allegretto WaveLight® EX500. Methods This study was a single-center, retrospective, noncomparative analysis of 400 eyes that underwent LASIK to correct for mixed astigmatism utilizing the EX500 excimer laser. Data on uncorrected distance visual acuity, corrected distance visual acuity, and spherical equivalent was analyzed at consecutive intervals (1, 3, 6, 9, and 12 months). Refractive measurements were used to perform a vector analysis. Results Three and 12 months postoperatively, 71% and 74% of eyes had an uncorrected distance visual acuity (UDVA) of 20/20 or better and 99% and 100% of eyes had a UDVA of 20/40 or better, respectively. The postoperative UDVA was within one line of the corrected distance visual acuity (CDVA) in 88% and 93% of eyes at 3 and 12 months, respectively. At 3 months, 78% of eyes achieved refractive astigmatism no greater than 0.50 diopters and at 12 months, 80% achieved this. The mean spherical equivalent refraction was − 0.36 ± 0.57 D at 12 months after surgery. At the 12-month follow-up, the mean refractive cylinder was reduced by 87%, from − 2.79 to − 0.37 diopters. On vector analysis, 99% of eyes had an angle of error within ± 15° from the intended target at 3 and 12 months. Conclusion Treatment of mixed astigmatism using the Allegretto WaveLight® EX500 laser exceeded the industry standards of safety, efficacy, stability, and accuracy.
- 23 January 2022
- Published by Elsevier in Survey of Ophthalmology
- Vol. 67 (4) , 1175-1199
The historical development and an overview of contemporary keratoprostheses
- 23 January 2022
- Published by Elsevier in Survey of Ophthalmology
- Vol. 67 (4) , 1175-1199
The historical development and an overview of contemporary keratoprostheses
- 1 June 2021
- Published by SAGE Publications in Tissue Engineering Part A
- Vol. 27 (11-12) , 714-723
Controlling Growth Factor Diffusion by Modulating Water Content in Injectable Hydrogels
Recent advancements in the delivery of therapeutics for retinal diseases include the development of injectable hydrogels, networks of one or more hydrophilic polymers that contain a high-volume fraction of water. These systems are of particular interest due to their biocompatibility, permeability to water-soluble metabolites, and function as minimally invasive injectable delivery vehicles. Recently, hydrogels for ophthalmic applications have been developed that display a controlled release of factors necessary for cellular survival and proliferation. Understanding the relationship between the volume water fraction and the physical, chemical, and diffusion properties of the hydrogel scaffold could aid in the improvement of existing drug delivery treatments for retinal regeneration. In this study, we compared the diffusion and release of human epidermal growth factor (hEGF) encapsulated in different injectable homogenous and heterogenous hydrogels, namely Gelatin (Gtn-HPA) and Hyaluronic acid (HA-Tyr)-based hydrogels. These experimental results were compared to the measured stiffness and water content of these hydrogels and applied to different diffusion theories of polymers to determine the model of best fit. We find that the normalized diffusion and release of hEGF increases with free water content in injectable hydrogels: ranging from 0.176 at 41% free water in HA-Tyr to 0.2 at 53% free water in Gtn-HPA, while it is decreasing with hydrogel stiffness: 600 Pa for Gtn-HPA and 1440 Pa for HA-Tyr. Furthermore, we compared our experimental data to theoretical diffusion models. We found that homogeneous theoretical models, notably the hydrodynamic model (giving a normalized diffusion close to 0.2), provide the most suitable explanation for the measured solute diffusion coefficient.
- 1 June 2021
- Published by SAGE Publications in Tissue Engineering Part A
- Vol. 27 (11-12) , 714-723
Controlling Growth Factor Diffusion by Modulating Water Content in Injectable Hydrogels
Recent advancements in the delivery of therapeutics for retinal diseases include the development of injectable hydrogels, networks of one or more hydrophilic polymers that contain a high-volume fraction of water. These systems are of particular interest due to their biocompatibility, permeability to water-soluble metabolites, and function as minimally invasive injectable delivery vehicles. Recently, hydrogels for ophthalmic applications have been developed that display a controlled release of factors necessary for cellular survival and proliferation. Understanding the relationship between the volume water fraction and the physical, chemical, and diffusion properties of the hydrogel scaffold could aid in the improvement of existing drug delivery treatments for retinal regeneration. In this study, we compared the diffusion and release of human epidermal growth factor (hEGF) encapsulated in different injectable homogenous and heterogenous hydrogels, namely Gelatin (Gtn-HPA) and Hyaluronic acid (HA-Tyr)-based hydrogels. These experimental results were compared to the measured stiffness and water content of these hydrogels and applied to different diffusion theories of polymers to determine the model of best fit. We find that the normalized diffusion and release of hEGF increases with free water content in injectable hydrogels: ranging from 0.176 at 41% free water in HA-Tyr to 0.2 at 53% free water in Gtn-HPA, while it is decreasing with hydrogel stiffness: 600 Pa for Gtn-HPA and 1440 Pa for HA-Tyr. Furthermore, we compared our experimental data to theoretical diffusion models. We found that homogeneous theoretical models, notably the hydrodynamic model (giving a normalized diffusion close to 0.2), provide the most suitable explanation for the measured solute diffusion coefficient.
- 16 April 2021
- Published by Springer Nature in International Ophthalmology
- Vol. 41 (8) , 2925-2932
The impact of vaping on ocular health: a literature review
Purpose Vaping, or the use of electronic cigarettes, was initially introduced as a step toward smoking cessation, but has become an increasingly popular option for smokers. Though advertised as safer than conventional cigarettes, these devices have been found to contain carcinogenic chemicals, air pollutants, and heavy metals. The purpose of this article is to shed light on the known effects of vaping on the ocular setting and raise the discussion about additional potential effects that may call for further investigation. Methods A comprehensive literature search was conducted for publications pertaining to the effects of vaping on the eye. Relevant studies and findings were summarized in this article. Results It was found that aldehydes and free radicals present in electronic cigarettes may induce a disturbance in tear film stability, and vape flavorings may damage the lipid layer through peroxidation. Corneal staining has been shown to appear following exposure to e-cigarette vapor, with nicotine and acrolein potentially inducing an inflammatory response in corneal epithelial cells. In addition, nicotine has been shown to induce nystagmus, exert vasoconstrictive effects on ocular blood flow, and may interfere with retinal light-adapted vision. Vape-related explosions, though unpredictable, may also result in decreased visual acuity along with long-term ocular trauma. Conclusion Research discussing both the short-term and long-term effects of vaping on the eye is limited. However, the potential harms of substances such as nicotine and aldehydes warrant additional investigation and increased education about the detriment that electronic cigarettes may inflict on sensitive organs.
- 16 April 2021
- Published by Springer Nature in International Ophthalmology
- Vol. 41 (8) , 2925-2932
The impact of vaping on ocular health: a literature review
Purpose Vaping, or the use of electronic cigarettes, was initially introduced as a step toward smoking cessation, but has become an increasingly popular option for smokers. Though advertised as safer than conventional cigarettes, these devices have been found to contain carcinogenic chemicals, air pollutants, and heavy metals. The purpose of this article is to shed light on the known effects of vaping on the ocular setting and raise the discussion about additional potential effects that may call for further investigation. Methods A comprehensive literature search was conducted for publications pertaining to the effects of vaping on the eye. Relevant studies and findings were summarized in this article. Results It was found that aldehydes and free radicals present in electronic cigarettes may induce a disturbance in tear film stability, and vape flavorings may damage the lipid layer through peroxidation. Corneal staining has been shown to appear following exposure to e-cigarette vapor, with nicotine and acrolein potentially inducing an inflammatory response in corneal epithelial cells. In addition, nicotine has been shown to induce nystagmus, exert vasoconstrictive effects on ocular blood flow, and may interfere with retinal light-adapted vision. Vape-related explosions, though unpredictable, may also result in decreased visual acuity along with long-term ocular trauma. Conclusion Research discussing both the short-term and long-term effects of vaping on the eye is limited. However, the potential harms of substances such as nicotine and aldehydes warrant additional investigation and increased education about the detriment that electronic cigarettes may inflict on sensitive organs.
- 31 December 2020
- Published by The Journal of Collegiate Emergency Medical Services in The Journal of Collegiate Emergency Medical Services
- Vol. 3 (2) , S6
Promoting Youth Emergency Preparedness through Lifesaving Emergency Skill Workshops
- 31 December 2020
- Published by The Journal of Collegiate Emergency Medical Services in The Journal of Collegiate Emergency Medical Services
- Vol. 3 (2) , S6
Promoting Youth Emergency Preparedness through Lifesaving Emergency Skill Workshops
- 29 October 2020
- Published by Wolters Kluwer Health in Current Opinion in Ophthalmology
- Vol. 32 (1) , 54-61
Refractive enhancements for residual refractive error after cataract surgery
Purpose of review: Advances in cataract surgery have allowed surgeons to achieve superior refractive outcomes but have also led to higher patient expectations. Despite ever-evolving technology, residual refractive errors still occur. Postcataract refractive enhancements may be required to deliver satisfactory visual outcomes. This review aims to discuss the potential causes of residual refractive errors and the various enhancement modalities to correct them. Recent findings: A thorough preoperative workup to detect and address underlying pathologic causes of impaired vision should be performed prior to enhancement or corrective procedures. Corneal-based procedures are the safest and most accurate methods of correcting mild cases of residual refractive error. Hyperopic, high myopic, and high astigmatic errors are best managed with lens-based enhancements. Piggyback intraocular lenses (IOLs) are safer and more effective compared with IOL exchange. Toric IOL rotation and IOL exchange are ideally performed in the early postoperative period. Summary: A multitude of options exist for effective correction of residual refractive errors. The choice on how to best manage these patients depends on many factors such as the cause of refractive error, type of IOL used, ocular comorbidities, and patient preference.
- 29 October 2020
- Published by Wolters Kluwer Health in Current Opinion in Ophthalmology
- Vol. 32 (1) , 54-61
Refractive enhancements for residual refractive error after cataract surgery
Purpose of review: Advances in cataract surgery have allowed surgeons to achieve superior refractive outcomes but have also led to higher patient expectations. Despite ever-evolving technology, residual refractive errors still occur. Postcataract refractive enhancements may be required to deliver satisfactory visual outcomes. This review aims to discuss the potential causes of residual refractive errors and the various enhancement modalities to correct them. Recent findings: A thorough preoperative workup to detect and address underlying pathologic causes of impaired vision should be performed prior to enhancement or corrective procedures. Corneal-based procedures are the safest and most accurate methods of correcting mild cases of residual refractive error. Hyperopic, high myopic, and high astigmatic errors are best managed with lens-based enhancements. Piggyback intraocular lenses (IOLs) are safer and more effective compared with IOL exchange. Toric IOL rotation and IOL exchange are ideally performed in the early postoperative period. Summary: A multitude of options exist for effective correction of residual refractive errors. The choice on how to best manage these patients depends on many factors such as the cause of refractive error, type of IOL used, ocular comorbidities, and patient preference.
- 29 October 2020
- Published by Wolters Kluwer Health in Current Opinion in Ophthalmology
- Vol. 32 (1) , 45-53
Use of presbyopia-correcting intraocular lenses in patients with prior corneal refractive surgery
Purpose of review: Corneal refractive surgery has achieved spectacle-free vision for millions of patients, but this aging population is now developing cataracts. Many of these patients may wish to avoid reliance on glasses after cataract surgery. Presbyopia-correcting intraocular lenses (IOLs) offer a solution, but corneal changes after refractive surgery may compound higher order aberrations and dysphotopic symptoms associated with these IOLs. This review aims to discuss potential factors that could aid in determining suitable postkeratorefractive candidates for presbyopia-correcting IOLs. Recent findings: Studies investigating which preoperative measures influence outcomes are lacking. The few studies that have examined presbyopia-correcting IOLs in postkeratorefractive patients report that satisfactory outcomes are possible. However, recommendations for preoperative thresholds appear limited to expert opinion and studies involving virgin corneas. Summary: As the number of presbyopia-correcting IOLs and postkeratorefractive patients grows, continued investigation into relevant preoperative factors and appropriate IOLs is required to make evidence-based decisions. The current literature shows that with rigorous counseling and appropriate patient selection, presbyopia-correcting IOLs can provide postkeratorefractive patients with satisfactory results and spectacle independence. In addition, the development of postoperative modifiable IOLs may prove to be the preferred option.
- 29 October 2020
- Published by Wolters Kluwer Health in Current Opinion in Ophthalmology
- Vol. 32 (1) , 45-53
Use of presbyopia-correcting intraocular lenses in patients with prior corneal refractive surgery
Purpose of review: Corneal refractive surgery has achieved spectacle-free vision for millions of patients, but this aging population is now developing cataracts. Many of these patients may wish to avoid reliance on glasses after cataract surgery. Presbyopia-correcting intraocular lenses (IOLs) offer a solution, but corneal changes after refractive surgery may compound higher order aberrations and dysphotopic symptoms associated with these IOLs. This review aims to discuss potential factors that could aid in determining suitable postkeratorefractive candidates for presbyopia-correcting IOLs. Recent findings: Studies investigating which preoperative measures influence outcomes are lacking. The few studies that have examined presbyopia-correcting IOLs in postkeratorefractive patients report that satisfactory outcomes are possible. However, recommendations for preoperative thresholds appear limited to expert opinion and studies involving virgin corneas. Summary: As the number of presbyopia-correcting IOLs and postkeratorefractive patients grows, continued investigation into relevant preoperative factors and appropriate IOLs is required to make evidence-based decisions. The current literature shows that with rigorous counseling and appropriate patient selection, presbyopia-correcting IOLs can provide postkeratorefractive patients with satisfactory results and spectacle independence. In addition, the development of postoperative modifiable IOLs may prove to be the preferred option.
- 15 September 2020
- Published by Wolters Kluwer Health in Cornea
- Vol. 40 (7) , 903-906
Case Report: Suspected Donor Transmission of Acanthamoeba Keratitis After Deep Anterior Lamellar Keratoplasty
Purpose: In our report, we present a suspected case of donor-derivedAcanthamoebakeratitis after deep anterior lamellar keratoplasty. To the authors' knowledge, there have been no confirmed cases ofAcanthamoebakeratitis transmission through corneal transplantation.Methods: Deep anterior lamellar keratoplasty was performed on the right eye of a 33-year-old man with severe bilateral keratoconus and an intolerance to all forms of contact lenses. The postoperative visual acuity deteriorated, while inflammation, rising ocular pressure, increasing corneal thickness, and severe eye pain began to present. Confocal imaging revealed hyperreflective cysts and trophozoite figures representative of amoebic keratitis. Despite an additional penetrating keratoplasty, antiamoeba therapy, and corneal crosslinking, the patient's condition worsened, resulting in stromal melt and corneal perforation. Emergent combined surgery of temporary keratoprosthesis, vitrectomy, lensectomy, and iridectomy was performed, along with Ahmed valve shunt placement and another penetrating keratoplasty.Results: The infection was resistant to aggressive antiamoeba therapy, but after the emergent combined surgery, the graft re-epithelialized quickly and has since remained clear, with no presence of keratitis.Conclusions: Several signs led us to believe that this case was donor-derived. There was little opportunity for graft exposure to the amoeba, and deep amoebic cysts and trophozoites were present on postoperative week 1—a highly unusual time course and depth of invasion for primary amoebic infection. In addition, pathological analysis revealed cysts only within the confines of the donor tissue and none in the recipient;Acanthamoebacysts would have been present in the recipient rim tissue if the infection originated from the patient himself.
- 15 September 2020
- Published by Wolters Kluwer Health in Cornea
- Vol. 40 (7) , 903-906
Case Report: Suspected Donor Transmission of Acanthamoeba Keratitis After Deep Anterior Lamellar Keratoplasty
Purpose: In our report, we present a suspected case of donor-derivedAcanthamoebakeratitis after deep anterior lamellar keratoplasty. To the authors' knowledge, there have been no confirmed cases ofAcanthamoebakeratitis transmission through corneal transplantation.Methods: Deep anterior lamellar keratoplasty was performed on the right eye of a 33-year-old man with severe bilateral keratoconus and an intolerance to all forms of contact lenses. The postoperative visual acuity deteriorated, while inflammation, rising ocular pressure, increasing corneal thickness, and severe eye pain began to present. Confocal imaging revealed hyperreflective cysts and trophozoite figures representative of amoebic keratitis. Despite an additional penetrating keratoplasty, antiamoeba therapy, and corneal crosslinking, the patient's condition worsened, resulting in stromal melt and corneal perforation. Emergent combined surgery of temporary keratoprosthesis, vitrectomy, lensectomy, and iridectomy was performed, along with Ahmed valve shunt placement and another penetrating keratoplasty.Results: The infection was resistant to aggressive antiamoeba therapy, but after the emergent combined surgery, the graft re-epithelialized quickly and has since remained clear, with no presence of keratitis.Conclusions: Several signs led us to believe that this case was donor-derived. There was little opportunity for graft exposure to the amoeba, and deep amoebic cysts and trophozoites were present on postoperative week 1—a highly unusual time course and depth of invasion for primary amoebic infection. In addition, pathological analysis revealed cysts only within the confines of the donor tissue and none in the recipient;Acanthamoebacysts would have been present in the recipient rim tissue if the infection originated from the patient himself.
- Open Access
- 20 June 2020
- Published by Springer Nature in Ophthalmology and Therapy
- Vol. 9 (3) , 465-483
A Contemporary Risk Analysis of Iatrogenic Transmission of Creutzfeldt-Jakob Disease (CJD) via Corneal Transplantation in the United States
Background Creutzfeldt-Jakob disease (CJD) is a rare, fatal, neurodegenerative prion disease potentially transmissible through corneal transplantation. While statistical analyses performed two decades ago estimated the overall prevalence of CJD in the corneal donor pool to be low, the recent significant increase in corneal transplants performed and deaths due to CJD in the U.S. warrants a contemporary risk analysis. Methods A literature review was conducted to determine the overall number of globally reported cases of CJD transmission through corneal transplantation. U.S. mortality and cornea donation data were utilized to estimate the age-stratified prevalence of undiagnosed, latent CJD in the cornea donor pool in 2018. A historical statistical analysis was performed to estimate the number of corneas from donors with latent CJD entering the U.S. donor pool for each year between 1979 and 2018. From these statistical analyses, risk factors of iatrogenic transmission were identified and summarized. Results Ten reported cases of iatrogenic transmission of CJD through corneal transplants were identified globally. In 2018, an estimated 3.8 corneas from donors with undiagnosed latent CJD potentially entered the pool of 111,703 transplant-intended corneas harvested from individuals aged 31–80. Between 1979 and 2018, an estimated 47 corneas may have entered the U.S. transplant-intended pool from donors with latent CJD aged 35 to 84. The advanced age of donors and a history of multiple transplants in recipients were both prominent risk factors for iatrogenic transmission. Conclusions The 10 reported global cases of iatrogenic transmission likely under-represent the number of individuals with a coinciding history of death by CJD and prior corneal transplantation, as supported by our statistical analysis and lack of geographical diversity of reported cases. As effective screening methods develop and globalization of cornea transplantation broadens, it is of utmost importance that cornea transplantation history among victims of CJD should be investigated and reported.
- 20 June 2020
- Published by Springer Nature in Ophthalmology and Therapy
- Vol. 9 (3) , 465-483
Open AccessA Contemporary Risk Analysis of Iatrogenic Transmission of Creutzfeldt-Jakob Disease (CJD) via Corneal Transplantation in the United States
Background Creutzfeldt-Jakob disease (CJD) is a rare, fatal, neurodegenerative prion disease potentially transmissible through corneal transplantation. While statistical analyses performed two decades ago estimated the overall prevalence of CJD in the corneal donor pool to be low, the recent significant increase in corneal transplants performed and deaths due to CJD in the U.S. warrants a contemporary risk analysis. Methods A literature review was conducted to determine the overall number of globally reported cases of CJD transmission through corneal transplantation. U.S. mortality and cornea donation data were utilized to estimate the age-stratified prevalence of undiagnosed, latent CJD in the cornea donor pool in 2018. A historical statistical analysis was performed to estimate the number of corneas from donors with latent CJD entering the U.S. donor pool for each year between 1979 and 2018. From these statistical analyses, risk factors of iatrogenic transmission were identified and summarized. Results Ten reported cases of iatrogenic transmission of CJD through corneal transplants were identified globally. In 2018, an estimated 3.8 corneas from donors with undiagnosed latent CJD potentially entered the pool of 111,703 transplant-intended corneas harvested from individuals aged 31–80. Between 1979 and 2018, an estimated 47 corneas may have entered the U.S. transplant-intended pool from donors with latent CJD aged 35 to 84. The advanced age of donors and a history of multiple transplants in recipients were both prominent risk factors for iatrogenic transmission. Conclusions The 10 reported global cases of iatrogenic transmission likely under-represent the number of individuals with a coinciding history of death by CJD and prior corneal transplantation, as supported by our statistical analysis and lack of geographical diversity of reported cases. As effective screening methods develop and globalization of cornea transplantation broadens, it is of utmost importance that cornea transplantation history among victims of CJD should be investigated and reported.
- Open Access
- 6 May 2020
- Published by Springer Nature in Ophthalmology and Therapy
- Vol. 9 (3) , 371-379
Risks Posed to Corneal Transplant Recipients by COVID-19-Affected Donors
The recent emergence of the novel severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) and its resultant human disease, COVID-19, will likely have a significant impact on the corneal tissue donor pool. Current recommendations from the United States and global eye bank associations call for the outright avoidance of tissues from donors recently infected with or exposed to COVID-19. This conservative recommendation is currently appropriate given the reported ocular sequelae, tear film viral detectability, and transmissibility of COVID-19. However, the rapidly increasing global prevalence and mortality of COVID-19 threatens the tenability of current tissue exclusion guidelines, and may necessitate their relaxation in the near future.
- 6 May 2020
- Published by Springer Nature in Ophthalmology and Therapy
- Vol. 9 (3) , 371-379
Open AccessRisks Posed to Corneal Transplant Recipients by COVID-19-Affected Donors
The recent emergence of the novel severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) and its resultant human disease, COVID-19, will likely have a significant impact on the corneal tissue donor pool. Current recommendations from the United States and global eye bank associations call for the outright avoidance of tissues from donors recently infected with or exposed to COVID-19. This conservative recommendation is currently appropriate given the reported ocular sequelae, tear film viral detectability, and transmissibility of COVID-19. However, the rapidly increasing global prevalence and mortality of COVID-19 threatens the tenability of current tissue exclusion guidelines, and may necessitate their relaxation in the near future.