HDHarald Dombrowski

Harald Dombrowski

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Harald Dombrowski has a total of 15 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Energy calibration of LaBr3 detectors using inherent radioactivity

    by Harald Dombrowski, Jörn Stenger

    In general, the energy calibration of gamma-ray detectors is carried out by using radioactive sources with well-known emission lines. The fact that the scintillator material LaBr3 includes natural radioactivity is often taken advantage of to perform an energy calibration without the need to handle an external radioactive source. For this purpose, the emission energy of photons to be detected in peaks has to be well known. Though the energies of the emission lines of the relevant isotope 138La and further information on radioactive contaminations are published with high precision, there are inconsistencies in the literature concerning the effective energies of observed photon peaks caused by inherent radioactivity. In this article, the actual peak positions are published as a result of high-precision measurements. The potential and limitations of an energy calibration of LaBr3 detectors based on the inherent radioactivity are discussed, as the emission lines of 138La are detected in clusters rather than single, clearly defined lines.

  • Open Access

    Quasi-continuous re-binning of measured spectra and associated uncertainties

    by H. Dombrowski

    As part of an evaluation of gamma-ray spectra or other spectra, the need to adapt the binning quasi-continuously may arise. Often, the re-distribution of measured events to a new energy scale may be required. The necessity to change the energy scale can have several reasons. Frequently, a drift of the detector or the amplifier leads to different energy scales of measured spectra in time. In order to calculate difference spectra or sum spectra, the energy axis and binning of all spectra has to be adapted. Moreover, before a spectrum is unfolded, its energy axis also has to be adapted to the energy scale of the response matrix. Widespread commercial software packages, which are commonly used for the analysis of spectra, do not include an algorithm which solves this task. Three algorithms are presented in this work after shedding light on the mathematical background. An analysis of the statistical uncertainty of the counts of re-binned or remapped spectra completes this paper.

  • Open Access

    Quantitative investigation of gamma radiation in accelerator produced ISO neutron fields

    by H Dombrowski, R Nolte

    In standard monoenergetic ISO neutron fields, the neutron yield of neutron-producing reactions was measured in combination with the prompt photon yield, including photon energies up to 10 MeV, for the purpose of comparing the two yields. Separating the photons produced by the target (direct photons) from those generated by secondary neutron reactions was achieved using the time-of-flight method. Photon and neutron ambient dose equivalent values were calculated from measured spectral energy distributions. Quasi monoenergetic neutron fields are needed to systematically test the response of measuring instruments to neutron radiation. For this reason, ISO has defined a number of reference neutron radiation fields covering a wide energy range up to 19 MeV. Because neutron detectors may also be affected by photon radiation, the photon fluence in the ISO neutron fields has to be known. This work focuses on quasi monoenergetic accelerator-produced neutron fields in the energy range of 24 keV to 19 MeV.


  • Open Access

    Comparison of the conversion method with gravel unfolding to obtain dose values from photon spectra

    by Harald Dombrowski

    Modern gamma-ray spectrometers based on solid-state scintillators are increasingly being used in fields where previously dosemeters were applied. From the spectra, precise fluence and dose information can be derived. The most important methods of doing this are investigated in detail; the conversion method, which is based on weighing functions; and unfolding, here using the GRAVEL algorithm. Both methods can be used to process any kind of spectra, regardless of the type of spectrometer employed. The GRAVEL algorithm is described in detail. The implementation of both methods is shown and results of examples are compared. Advantages and disadvantages of both techniques are discussed. For the first time, most precise conversion data up to 20 MeV are published, even extending the quantity H*(10) to this energy. They may serve for the improvement and harmonisation of dose rate measurements using scintillation spectrometers, e.g. those used in early warning systems.


  • Open Access

    GRAVEL unfolding of gamma-ray spectra of CeBr3 detectors and related uncertainties

    by H. Dombrowski

    Unfolded spectra are needed for the application of some spectrum analysis methods. Frequently, iterative deconvolution methods are used, especially if the spectra have a high resolution. However, the uncertainties on the obtained results are difficult to judge. In general, the user of an unfolding code gets no information on the influence of chosen parameters, especially the choice of the first estimate of the unfolded spectrum. General studies regarding the uncertainties of unfolding algorithms are difficult to perform, if not impossible, and therefore not available. In this work, uncertainties of the results on the iterative GRAVEL algorithm, which is based on SAND II, are closely investigated by using medium resolution spectra recorded by using a CeBr3 detector. Relevant parameters are varied systematically to gain some information on the associated uncertainties on the basis of examples. The uncertainty budget of the calculation of total fluences and doses of unfolded spectra is compared with the uncertainty budget of the results obtained by applying the conversion method. The results allow, at least, the estimation of the magnitude of typical uncertainties.


  • Open Access

    Preparedness intercomparison of passive H*(10) area photon dosemeters in 2017/2018 (IC2017prep)

    by H. Dombrowski

    This intercomparison serves to investigate the long-term behaviour of passive H*(10) dosemeters which may be used in the aftermath of a radiological or nuclear event. In routine operation, such dosemeters are generally used to monitor installations like nuclear power plants and accelerators. Such dosemeters are used in the radiation field of the natural ambient radiation, including terrestrial and secondary cosmic radiation. From October 2017 to April 2018, photon dosemeters of 38 dosimetry systems were exposed to ionising radiation at three dosimetric reference sites which are operated by the Physikalisch-Technische Bundesanstalt (PTB). In addition to measurements which were carried out under natural conditions, a number of dosemeters was also irradiated artificially under two angles in PTB's photon fields. 34 measuring bodies and institutions which are mainly involved in ambient radiation monitoring in Europe took part in this intercomparison in which the response of the dosemeters to terrestrial and also to secondary cosmic radiation was determined. As a result of this intercomparison, some sources of uncertainty and some errors were found. The intercomparison revealed the typical precision that has to be expected when long-term dose measurements are carried out in the natural environment. The successful participation in this intercomparison was documented by certificates that were issued to the participants. The short designation of this intercomparison is “IC2017prep”.


  • ON THE CONVERSION COEFFICIENT FROM AIR KERMA TO AMBIENT DOSE EQUIVALENT VALID FOR A CS-137 PHOTON FIELD—A CRITICAL REVIEW

    by H Dombrowski

    In radiation protection, the quantity ambient dose equivalent, in short H*(10), is very important in the field of area dosimetry, because this quantity is used to estimate the effective dose to human beings, whose permissible limits are restricted by law. The conversion coefficient from air kerma to H*(10), valid for a 137Cs photon field, is essential as it enters the realization of the quantity H*(10) as well as every (directly or indirectly) related calibration. The basic calibration factor of any dose rate instrument is usually related to a calibration in a 137Cs photon field, which underlines the importance of the conversion coefficient discussed in this article. Because different values of this coefficient are used in different calibration facilities, a harmonized best value will be proposed based on detailed investigations on the origin of the values recommended in the past. The newly recommended value differs by almost 1% from the value used by most institutes, at the moment, which is large in comparison with the typical uncertainties in primary fields. The goal of this article is to interpret known ICRU/ICRP data adequately, not to calculate new data.


  • Comparison of the uncertainties of several European low-dose calibration facilities

    by H. Dombrowski, N.A. Cornejo Díaz, M.P. Toni, M. Mihelic, A. Röttger


  • Open Access

    Recommendations to harmonize European early warning dosimetry network systems

    by H. Dombrowski, M. Bleher, M. De Cort, R. Dabrowski, S. Neumaier, U. Stöohlker


  • EURADOS intercomparisons and the harmonisation of environmental radiation monitoring

    by S. Neumaier, H. Dombrowski

    After the Chernobyl nuclear power plant accident in 1986, all Member States of the European Union have installed area dose rate monitoring networks so that radiological incidents can be detected quickly. However, the different technical approaches and procedures led to inconsistencies in the area dose rate data. In the last 15 years, the working group 'Environmental Radiation Monitoring' of the European Radiation Dosimetry Group (EURADOS) has performed six pan-European intercomparison exercises for detector systems operated in national dosimetric early warning networks. These intercomparisons aimed at the harmonisation of area dose rate measurements of radiation monitoring stations in Europe. The intercomparisons revealed differences in technical properties of the dose rate monitoring systems as well as in the calibration and measuring methods that led to deviations of measured dose rate values by a factor of 5 or more under the same measuring conditions. As a result of the intercomparisons, the accuracy of dose rate measurements could be improved considerably. Further progress in metrologically correct measurements of area dose rates in the natural environment and necessary steps towards a metrologically sound pan-European system for environmental radiation monitoring will be discussed.