Thália Raelly de Lima Meneses Romeiro
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Thália Raelly de Lima Meneses Romeiro has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Elton Bauer
Universidade de Brasília, Brasil
2 shared publications - Ana Luiza Rocha de Souza
Universidade de Brasília
1 shared publication - Ana Luiza Rocha de Souza
Department of Civil and Environmental Engineering, SG-12, University of Brasília (UnB), Brasilia 70910-900, Brazil
1 shared publication - Maykon Vieira Silva
Universidade de Brasília - UnB
1 shared publication - Melissa Lorrane Frazão Lopes
Universidade de Brasília, Brasil
1 shared publication
Latest Publications
- Open Access
Influence of the Exposure Degree on the Degradation of Facades of Buildings in Brasília—Brazil
Facades play an important role in building performance and durability since these systems, one of the most external elements, are highly exposed to climatic degradation agents. The degradation process evolves over time, causing anomalies and performance failures, ultimately reducing the building’s service life. When directly influenced by the agents and mechanisms, the expected degradation of the systems that constitute the facade depends on the degree of exposure to the agents and how the degradation mechanisms act under different conditions. Given the relevance of the topic and the need for information on the degradation process of facade elements, this investigation aims to evaluate the relationship between the degradation measured in buildings in Brasília and the exposure degree of the facades, focusing on climatic degradation agents. The facades are evaluated regarding exposure to driving rain and solar radiation and classified into two groups: high exposure and low exposure. The sample degradation was quantified using the Degradation Measurement Method (DMM) and the General Degradation Factor (FGD). This methodology showed both the behavior models for the different exposure groups and allowed us to calculate estimated service life (ESL) values of approximately 26 and 35 years for facades with high and low exposures, respectively. The FGD values are higher for facades with high exposure compared to those with lower exposure. Additionally, North-oriented facades are the most critical, exhibiting the highest degradation levels due to the greater intensity of driving rain and incident solar radiation.
Open AccessInfluence of the Exposure Degree on the Degradation of Facades of Buildings in Brasília—Brazil
Facades play an important role in building performance and durability since these systems, one of the most external elements, are highly exposed to climatic degradation agents. The degradation process evolves over time, causing anomalies and performance failures, ultimately reducing the building’s service life. When directly influenced by the agents and mechanisms, the expected degradation of the systems that constitute the facade depends on the degree of exposure to the agents and how the degradation mechanisms act under different conditions. Given the relevance of the topic and the need for information on the degradation process of facade elements, this investigation aims to evaluate the relationship between the degradation measured in buildings in Brasília and the exposure degree of the facades, focusing on climatic degradation agents. The facades are evaluated regarding exposure to driving rain and solar radiation and classified into two groups: high exposure and low exposure. The sample degradation was quantified using the Degradation Measurement Method (DMM) and the General Degradation Factor (FGD). This methodology showed both the behavior models for the different exposure groups and allowed us to calculate estimated service life (ESL) values of approximately 26 and 35 years for facades with high and low exposures, respectively. The FGD values are higher for facades with high exposure compared to those with lower exposure. Additionally, North-oriented facades are the most critical, exhibiting the highest degradation levels due to the greater intensity of driving rain and incident solar radiation.
- Open Access
- 26 November 2023
- Published by Associacao Nacional de Tecnologia do Ambiente Construido (ANTAC) in SIMPÓSIO BRASILEIRO DE TECNOLOGIA DAS ARGAMASSAS
- Vol. 14
ESTUDO DA DISTRIBUIÇÃO DA DEGRADAÇÃO DE FACHADAS NOS DIFERENTES ANDARES DOS EDIFÍCIOS
A incidência de agentes de degradação sobre os edifícios é responsável pelo processo de degradação. O objetivo deste estudo é investigar a distribuição da degradação de fachadas nos diferentes andares de edifícios compostos por sistema de revestimento cerâmico aderido. O estudo é aplicado para 5 edifícios de Brasília selecionados de uma base de dados, utilizando o método MMD para a quantificação da ocorrência da degradação. As análises são baseadas em indicadores de degradação, calculados a partir das variáveis investigadas, como a orientação e posição na fachada (especificamente os andares das amostras). O Topo do edifício é o pavimento que apresenta maior degradação.
- 26 November 2023
- Published by Associacao Nacional de Tecnologia do Ambiente Construido (ANTAC) in SIMPÓSIO BRASILEIRO DE TECNOLOGIA DAS ARGAMASSAS
- Vol. 14
Open AccessESTUDO DA DISTRIBUIÇÃO DA DEGRADAÇÃO DE FACHADAS NOS DIFERENTES ANDARES DOS EDIFÍCIOS
A incidência de agentes de degradação sobre os edifícios é responsável pelo processo de degradação. O objetivo deste estudo é investigar a distribuição da degradação de fachadas nos diferentes andares de edifícios compostos por sistema de revestimento cerâmico aderido. O estudo é aplicado para 5 edifícios de Brasília selecionados de uma base de dados, utilizando o método MMD para a quantificação da ocorrência da degradação. As análises são baseadas em indicadores de degradação, calculados a partir das variáveis investigadas, como a orientação e posição na fachada (especificamente os andares das amostras). O Topo do edifício é o pavimento que apresenta maior degradação.