YLYiyun Liu

Yiyun Liu

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Yiyun Liu has a total of 16 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Ocular Biometry Features and Their Relationship with Anterior and Posterior Segment Lengths among a Myopia Population in Northern China

    by Linbo Bian, Wenlong Li, Rui Qin, Zhengze Sun, Lu Zhao, Yifan Zhou, Dehai Liu, Yiyun Liu, Tong Sun, Hong Qi

    Objectives: The study aims to explore the ocular biometry of a myopic population in Northern China, focusing specifically on anterior and posterior segment lengths. Methods: This is a cross-sectional study. The medical records of 3458 myopic patients who underwent refractive surgery were evaluated. Axial length (AL), anterior chamber depth (ACD), lens thickness (LT) and other biometric parameters were measured using the IOL Master 700. The study determined the anterior segment length (ASL = ACD + LT), the posterior segment length (PSL = AL − ASL) and the ratio of ASL to PSL (ASL/PSL). Results: This study included 3458 eyes from 3458 myopic patients (1171 men and 2287 women). The mean age was 27.38 ± 6.88, ranging from 16 to 48 years old. The mean ASL was 7.35 ± 0.27 mm, and the mean PSL was 18.39 ± 1.18 mm. The ASL and PSL trends demonstrate an age-related increase for both genders, with notable gender-specific variations. Across most age groups, males typically exhibited higher ASLs and PSLs than females, with the exception of the 35–40 and 40–45 age groups. The ASL and PSL consistently increased with a rising AL. The AL strongly correlates with the PSL and negatively correlates with the ASL/PSL ratio. The ACD and LT moderately correlate with the ASL, but an increased LT does not imply a longer posterior segment. The CCT and SE show little correlation with axial eye parameters. Conclusions: Among Chinese myopic patients, a longer ASL and PSL were correlated with older age and the male gender. The AL strongly correlates positively with the PSL and negatively correlates with the ASL/PSL ratio. An elongation of the posterior segment may primarily account for an eyeball’s lengthening.


  • Open Access

    Interpretable Detection of Diabetic Retinopathy, Retinal Vein Occlusion, Age-Related Macular Degeneration, and Other Fundus Conditions

    by Wenlong Li, Linbo Bian, Baikai Ma, Tong Sun, Yiyun Liu, Zhengze Sun, Lin Zhao, Kang Feng, Fan Yang, Xiaona Wang, et al.

    Diabetic retinopathy (DR), retinal vein occlusion (RVO), and age-related macular degeneration (AMD) pose significant global health challenges, often resulting in vision impairment and blindness. Automatic detection of these conditions is crucial, particularly in underserved rural areas with limited access to ophthalmic services. Despite remarkable advancements in artificial intelligence, especially convolutional neural networks (CNNs), their complexity can make interpretation difficult. In this study, we curated a dataset consisting of 15,089 color fundus photographs (CFPs) obtained from 8110 patients who underwent fundus fluorescein angiography (FFA) examination. The primary objective was to construct integrated models that merge CNNs with an attention mechanism. These models were designed for a hierarchical multilabel classification task, focusing on the detection of DR, RVO, AMD, and other fundus conditions. Furthermore, our approach extended to the detailed classification of DR, RVO, and AMD according to their respective subclasses. We employed a methodology that entails the translation of diagnostic information obtained from FFA results into CFPs. Our investigation focused on evaluating the models’ ability to achieve precise diagnoses solely based on CFPs. Remarkably, our models showcased improvements across diverse fundus conditions, with the ConvNeXt-base + attention model standing out for its exceptional performance. The ConvNeXt-base + attention model achieved remarkable metrics, including an area under the receiver operating characteristic curve (AUC) of 0.943, a referable F1 score of 0.870, and a Cohen’s kappa of 0.778 for DR detection. For RVO, it attained an AUC of 0.960, a referable F1 score of 0.854, and a Cohen’s kappa of 0.819. Furthermore, in AMD detection, the model achieved an AUC of 0.959, an F1 score of 0.727, and a Cohen’s kappa of 0.686. Impressively, the model demonstrated proficiency in subclassifying RVO and AMD, showcasing commendable sensitivity and specificity. Moreover, our models enhanced interpretability by visualizing attention weights on fundus images, aiding in the identification of disease findings. These outcomes underscore the substantial impact of our models in advancing the detection of DR, RVO, and AMD, offering the potential for improved patient outcomes and positively influencing the healthcare landscape.