Kris De Braekeleer
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Kris De Braekeleer has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Abdelaziz Bouklouze
Biopharmaceutical and Toxicological Analysis Research Team, Laboratory of Pharmacology and Toxicology, Faculty of Medicine and Pharmacy, University Mohammed V, Rabat 10100, Morocco
2 shared publications - Meryeme El Maouardi
Biopharmaceutical and Toxicological Analysis Research Team, Laboratory of Pharmacology and Toxicology, Faculty of Medicine and Pharmacy, University Mohammed V, Rabat 10100, Morocco
2 shared publications - Yvan Vander Heyden
Department of Analytical Chemistry, Applied Chemometrics and Molecular Modelling, Vrije Universiteit Brussel (VUB), Brussels, Belgium
2 shared publications Corenthin Mees
Faculté de Pharmacie, RD3 ‐ Pharmacognosy, Bioanalysis and Drug Research Unit Université Libre de Bruxelles Brussels Belgium
1 shared publication- Cédric Delporte
RD3 Unit of Pharmacognosy, Bioanalysis and Drug Discovery, Faculty of Pharmacy, Université Libre de Bruxelles, Brussels, Belgium
1 shared publication - Eric Deconinck
Section of Medicines and Health Products, Sciensano, J. Wytsmanstraat 14, B-1050 Brussels, Belgium
1 shared publication
Latest Publications
- Open Access
- 5 January 2024
- Published by MDPI AG in Chemosensors
- Vol. 12 (1) , 9
Spectroscopy and Chemometrics for Conformity Analysis of e-Liquids: Illegal Additive Detection and Nicotine Characterization
Vaping electronic cigarettes (e-cigarettes) has become a popular alternative to smoking tobacco. When an e-cigarette is activated, a liquid is vaporized by heating, producing an aerosol that users inhale. While e-cigarettes are marketed as less harmful than traditional cigarettes, there are ongoing concerns about their long-term health effects, including potential lung damage. Therefore, it is essential to closely monitor and study the composition of e-liquids. E-liquids typically consist of propylene glycol, glycerin, flavorings and nicotine, though there have been reports of non-compliant nicotine concentrations and the presence of illegal additives. This study explored spectroscopic techniques to examine the conformity of nicotine labeling and detect the presence of the not-allowed additives: the caffeine, taurine, vitamin E and cannabidiol (CBD) in e-liquids. A total of 236 e-liquid samples were carefully selected for analysis. Chemometric analysis was applied to the collected data, which included mid-infrared (MIR) and near-infrared (NIR) spectra. Supervised modeling approaches such as partial least squares-discriminant analysis (PLS-DA) and soft independent modeling of class analogy (SIMCA) were employed to classify the samples, based on the presence of nicotine and the targeted additives. This study demonstrates the efficacy of MIR and NIR spectroscopic techniques in conjunction with chemometric methods (SIMCA and PLS-DA) for detecting specific molecules in e-liquids. MIR with autoscaling data preprocessing and PLS-DA achieved 100% classification rates for CBD and vitamin E, while NIR with the same approach achieved 100% for CBD and taurine. Overall, MIR combined with PLS-DA yielded the best classification across all targeted molecules, suggesting its preference as a singular technique.
- 5 January 2024
- Published by MDPI AG in Chemosensors
- Vol. 12 (1) , 9
Open AccessSpectroscopy and Chemometrics for Conformity Analysis of e-Liquids: Illegal Additive Detection and Nicotine Characterization
Vaping electronic cigarettes (e-cigarettes) has become a popular alternative to smoking tobacco. When an e-cigarette is activated, a liquid is vaporized by heating, producing an aerosol that users inhale. While e-cigarettes are marketed as less harmful than traditional cigarettes, there are ongoing concerns about their long-term health effects, including potential lung damage. Therefore, it is essential to closely monitor and study the composition of e-liquids. E-liquids typically consist of propylene glycol, glycerin, flavorings and nicotine, though there have been reports of non-compliant nicotine concentrations and the presence of illegal additives. This study explored spectroscopic techniques to examine the conformity of nicotine labeling and detect the presence of the not-allowed additives: the caffeine, taurine, vitamin E and cannabidiol (CBD) in e-liquids. A total of 236 e-liquid samples were carefully selected for analysis. Chemometric analysis was applied to the collected data, which included mid-infrared (MIR) and near-infrared (NIR) spectra. Supervised modeling approaches such as partial least squares-discriminant analysis (PLS-DA) and soft independent modeling of class analogy (SIMCA) were employed to classify the samples, based on the presence of nicotine and the targeted additives. This study demonstrates the efficacy of MIR and NIR spectroscopic techniques in conjunction with chemometric methods (SIMCA and PLS-DA) for detecting specific molecules in e-liquids. MIR with autoscaling data preprocessing and PLS-DA achieved 100% classification rates for CBD and vitamin E, while NIR with the same approach achieved 100% for CBD and taurine. Overall, MIR combined with PLS-DA yielded the best classification across all targeted molecules, suggesting its preference as a singular technique.
- Open Access
Evaluation of Multivariate Filters on Vibrational Spectroscopic Fingerprints for the PLS-DA and SIMCA Classification of Argan Oils from Four Moroccan Regions
This study aimed to develop an analytical method to determine the geographical origin of Moroccan Argan oil through near-infrared (NIR) or mid-infrared (MIR) spectroscopic fingerprints. However, the classification may be problematic due to the spectral similarity of the components in the samples. Therefore, unsupervised and supervised classification methods—including principal component analysis (PCA), Partial Least Squares-Discriminant Analysis (PLS-DA) and Soft Independent Modeling of Class Analogy (SIMCA)—were evaluated to distinguish between Argan oils from four regions. The spectra of 93 samples were acquired and preprocessed using both standard preprocessing methods and multivariate filters, such as External Parameter Orthogonalization, Generalized Least Squares Weighting and Orthogonal Signal Correction, to improve the models. Their accuracy, precision, sensitivity, and selectivity were used to evaluate the performance of the models. SIMCA and PLS-DA models generated after standard preprocessing failed to correctly classify all samples. However, successful models were produced after using multivariate filters. The NIR and MIR classification models show an equivalent accuracy. The PLS-DA models outperformed the SIMCA with 100% accuracy, specificity, sensitivity and precision. In conclusion, the studied multivariate filters are applicable on the spectroscopic fingerprints to geographically identify the Argan oils in routine monitoring, significantly reducing analysis costs and time.
Open AccessEvaluation of Multivariate Filters on Vibrational Spectroscopic Fingerprints for the PLS-DA and SIMCA Classification of Argan Oils from Four Moroccan Regions
This study aimed to develop an analytical method to determine the geographical origin of Moroccan Argan oil through near-infrared (NIR) or mid-infrared (MIR) spectroscopic fingerprints. However, the classification may be problematic due to the spectral similarity of the components in the samples. Therefore, unsupervised and supervised classification methods—including principal component analysis (PCA), Partial Least Squares-Discriminant Analysis (PLS-DA) and Soft Independent Modeling of Class Analogy (SIMCA)—were evaluated to distinguish between Argan oils from four regions. The spectra of 93 samples were acquired and preprocessed using both standard preprocessing methods and multivariate filters, such as External Parameter Orthogonalization, Generalized Least Squares Weighting and Orthogonal Signal Correction, to improve the models. Their accuracy, precision, sensitivity, and selectivity were used to evaluate the performance of the models. SIMCA and PLS-DA models generated after standard preprocessing failed to correctly classify all samples. However, successful models were produced after using multivariate filters. The NIR and MIR classification models show an equivalent accuracy. The PLS-DA models outperformed the SIMCA with 100% accuracy, specificity, sensitivity and precision. In conclusion, the studied multivariate filters are applicable on the spectroscopic fingerprints to geographically identify the Argan oils in routine monitoring, significantly reducing analysis costs and time.
- Open Access
Quality Control and Authentication of Argan Oils: Application of Advanced Analytical Techniques
In addition to the nutritional and therapeutic benefits, Argan oil is praised for its unique bio-ecological and botanic interest. It has been used for centuries to treat cardiovascular issues, diabetes, and skin infections, as well as for its anti-inflammatory and antiproliferative properties. Argan oil is widely commercialized as a result of these characteristics. However, falsifiers deliberately blend Argan oil with cheaper vegetable oils to make economic profits. This reduces the quality and might result in health issues for consumers. Analytical techniques that are rapid, precise, and accurate are employed to monitor its quality, safety, and authenticity. This review provides a comprehensive overview of studies on the quality assessment of Moroccan Argan oil using both untargeted and targeted approaches. To extract relevant information on quality and adulteration, the analytical data are coupled with chemometric techniques.
Open AccessQuality Control and Authentication of Argan Oils: Application of Advanced Analytical Techniques
In addition to the nutritional and therapeutic benefits, Argan oil is praised for its unique bio-ecological and botanic interest. It has been used for centuries to treat cardiovascular issues, diabetes, and skin infections, as well as for its anti-inflammatory and antiproliferative properties. Argan oil is widely commercialized as a result of these characteristics. However, falsifiers deliberately blend Argan oil with cheaper vegetable oils to make economic profits. This reduces the quality and might result in health issues for consumers. Analytical techniques that are rapid, precise, and accurate are employed to monitor its quality, safety, and authenticity. This review provides a comprehensive overview of studies on the quality assessment of Moroccan Argan oil using both untargeted and targeted approaches. To extract relevant information on quality and adulteration, the analytical data are coupled with chemometric techniques.
- 17 January 2022
- Published by Wiley in Journal of Chemometrics
- Vol. 36 (3) , e3389
Benchtop NIR data standardization on handheld spectrometers to identify paracetamol tablets
Near‐infrared spectroscopy (NIRS) allows innovative applications in terms of quality control, for example, in raw materials verification, in process analytical technology (PAT), and in discrimination between genuine and falsified medicines. The development of small and cheap handheld devices is expanding in the field, while trying to keep similar performances as benchtop instruments have. Considering traceability and quality control of drug compounds, this work is intended to identify 13 different paracetamol tablets on the Belgian market by using NIRS. The performances of a Fourier‐transform near‐infrared spectroscopy (FT‐NIR) benchtop and two handheld NIR spectrometers were investigated comparatively. All spectra were collected through the blister in the reflectance diffuse mode. NIR spectral fingerprints were pretreated and analyzed using principal component analysis (PCA) and classified with soft independent modeling of class analogy (SIMCA). The performances of the spectrometers were evaluated after standardization of the reference benchtop database to the handheld spectrometers. The instrumental response of the benchtop spectrometer was standardized towards the handheld device using the piecewise direct standardization (PDS) algorithm. These investigations permitted the advantages and limitations of NIR data standardization on predictive models to be pointed out. The SIMCA models based on the spectral data of the benchtop (B), handheld 1 (H1), and handheld 2 (H2) instruments had an accuracy of 99.2%, 97.7%, and 96.2%, respectively. The same accuracy was obtained with the models of the transferred benchtop spectra for the H1 and H2 devices. However, adding handheld spectra to the transferred benchtop spectra resulted in models with improved accuracy: from 97.7% to 98.5% for the H1 instrument and from 96.2% to 97.7% for the H2 instrument. The proposed strategy highlights the potential of using a reference database collected by NIRS for pharmaceutical analyses by handheld NIR spectrometers in terms of traceability.
- 17 January 2022
- Published by Wiley in Journal of Chemometrics
- Vol. 36 (3) , e3389
Benchtop NIR data standardization on handheld spectrometers to identify paracetamol tablets
Near‐infrared spectroscopy (NIRS) allows innovative applications in terms of quality control, for example, in raw materials verification, in process analytical technology (PAT), and in discrimination between genuine and falsified medicines. The development of small and cheap handheld devices is expanding in the field, while trying to keep similar performances as benchtop instruments have. Considering traceability and quality control of drug compounds, this work is intended to identify 13 different paracetamol tablets on the Belgian market by using NIRS. The performances of a Fourier‐transform near‐infrared spectroscopy (FT‐NIR) benchtop and two handheld NIR spectrometers were investigated comparatively. All spectra were collected through the blister in the reflectance diffuse mode. NIR spectral fingerprints were pretreated and analyzed using principal component analysis (PCA) and classified with soft independent modeling of class analogy (SIMCA). The performances of the spectrometers were evaluated after standardization of the reference benchtop database to the handheld spectrometers. The instrumental response of the benchtop spectrometer was standardized towards the handheld device using the piecewise direct standardization (PDS) algorithm. These investigations permitted the advantages and limitations of NIR data standardization on predictive models to be pointed out. The SIMCA models based on the spectral data of the benchtop (B), handheld 1 (H1), and handheld 2 (H2) instruments had an accuracy of 99.2%, 97.7%, and 96.2%, respectively. The same accuracy was obtained with the models of the transferred benchtop spectra for the H1 and H2 devices. However, adding handheld spectra to the transferred benchtop spectra resulted in models with improved accuracy: from 97.7% to 98.5% for the H1 instrument and from 96.2% to 97.7% for the H2 instrument. The proposed strategy highlights the potential of using a reference database collected by NIRS for pharmaceutical analyses by handheld NIR spectrometers in terms of traceability.