Zhensen Chen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Zhensen Chen has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Jieyun Bai
College of Information Science and Technology, Jinan University, Guangzhou, China
4 shared publications Yaosheng Lu
Guangdong Provincial Key Laboratory of Traditional Chinese Medicine Information Technology, Jinan University, Guangzhou, China
4 shared publications- Victor M. Campello
Departament de Matemàtiques i Informàtica, Universitat de Barcelona, Barcelona, Spain
2 shared publications Zhanhong Ou
2 shared publicationsKarim Lekadir
1 shared publication- Karim Lekadir
Universitat de Barcelona
1 shared publication
Latest Publications
- 17 April 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Circuits and Systems for Video Technology
- Vol. PP (10518215) , 1
Dual-Path Hybrid Network for Boundary-Aware Segmentation and Angle of Progression Measurement in Intrapartum Ultrasound
Accurate segmentation of the fetal head (FH) and pubic symphysis (PS) in intrapartum ultrasound (IU) images is a crucial step for automatic angle of progression (AoP) measurement, which plays an essential role in predicting delivery outcomes and reducing maternal and fetal complications. Existing CNN–Transformer hybrid models often suffer from attention collapse due to limited medical data and tend to overlook boundary details that are critical yet highly degraded by artifacts and noise in IU images. To address these issues, we propose a CNN-stylized dual-path CNN–Transformer hybrid network tailored for IU segmentation. The encoder integrates a parallel CNN branch and a CNN-stylized Transformer branch to balance local feature extraction and global dependency modeling while mitigating attention collapse. A Transformer-to-CNN fusion module further enhances cross-branch information interaction. In the decoder, a Boundary Attention Residual Module captures subtle foreground-background transitions and progressively refines boundary features. In addition, an Adaptive Boundary Enhancement strategy is designed to emphasize challenging boundary regions during CutMix augmentation. Experiments on three datasets demonstrate that our method outperforms state-of-the-art approaches in both overall accuracy and boundary precision. The automatic AoP measurement analysis further validates its potential for clinical translation. Code is available at https://github.com/SakuraKong/Dual-Path-CNN-Stylized-Hybrid-Network.
- 17 April 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Circuits and Systems for Video Technology
- Vol. PP (10518215) , 1
Dual-Path Hybrid Network for Boundary-Aware Segmentation and Angle of Progression Measurement in Intrapartum Ultrasound
Accurate segmentation of the fetal head (FH) and pubic symphysis (PS) in intrapartum ultrasound (IU) images is a crucial step for automatic angle of progression (AoP) measurement, which plays an essential role in predicting delivery outcomes and reducing maternal and fetal complications. Existing CNN–Transformer hybrid models often suffer from attention collapse due to limited medical data and tend to overlook boundary details that are critical yet highly degraded by artifacts and noise in IU images. To address these issues, we propose a CNN-stylized dual-path CNN–Transformer hybrid network tailored for IU segmentation. The encoder integrates a parallel CNN branch and a CNN-stylized Transformer branch to balance local feature extraction and global dependency modeling while mitigating attention collapse. A Transformer-to-CNN fusion module further enhances cross-branch information interaction. In the decoder, a Boundary Attention Residual Module captures subtle foreground-background transitions and progressively refines boundary features. In addition, an Adaptive Boundary Enhancement strategy is designed to emphasize challenging boundary regions during CutMix augmentation. Experiments on three datasets demonstrate that our method outperforms state-of-the-art approaches in both overall accuracy and boundary precision. The automatic AoP measurement analysis further validates its potential for clinical translation. Code is available at https://github.com/SakuraKong/Dual-Path-CNN-Stylized-Hybrid-Network.
- 13 May 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Biomedical and Health Informatics
- Vol. 28 (8) , 4648-4659
Fetal Head and Pubic Symphysis Segmentation in Intrapartum Ultrasound Image Using a Dual-Path Boundary-Guided Residual Network
Accurate segmentation of the fetal head and pubic symphysis in intrapartum ultrasound images and measurement of fetal angle of progression (AoP) are critical to both outcome prediction and complication prevention in delivery. However, due to poor quality of perinatal ultrasound imaging with blurred target boundaries and the relatively small target of the public symphysis, fully automated and accurate segmentation remains challenging. In this paper, we propse a dual-path boundary-guided residual network (DBRN), which is a novel approach to tackle these challenges. The model contains a multi-scale weighted module (MWM) to gather global context information, and enhance the feature response within the target region by weighting the feature map. The model also incorporates an enhanced boundary module (EBM) to obtain more precise boundary information. Furthermore, the model introduces a boundary-guided dual-attention residual module (BDRM) for residual learning. BDRM leverages boundary information as prior knowledge and employs spatial attention to simultaneously focus on background and foreground information, in order to capture concealed details and improve segmentation accuracy. Extensive comparative experiments have been conducted on three datasets. The proposed method achieves average Dice score of 0.908 $\pm$ 0.05 and average Hausdorff distance of 3.396 $\pm$ 0.66 mm. Compared with state-of-the-art competitors, the proposed DBRN achieves better results. In addition, the average difference between the automatic measurement of AoPs based on this model and the manual measurement results is 6.157 $^{\circ }$ , which has good consistency and has broad application prospects in clinical practice.
- 13 May 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Biomedical and Health Informatics
- Vol. 28 (8) , 4648-4659
Fetal Head and Pubic Symphysis Segmentation in Intrapartum Ultrasound Image Using a Dual-Path Boundary-Guided Residual Network
Accurate segmentation of the fetal head and pubic symphysis in intrapartum ultrasound images and measurement of fetal angle of progression (AoP) are critical to both outcome prediction and complication prevention in delivery. However, due to poor quality of perinatal ultrasound imaging with blurred target boundaries and the relatively small target of the public symphysis, fully automated and accurate segmentation remains challenging. In this paper, we propse a dual-path boundary-guided residual network (DBRN), which is a novel approach to tackle these challenges. The model contains a multi-scale weighted module (MWM) to gather global context information, and enhance the feature response within the target region by weighting the feature map. The model also incorporates an enhanced boundary module (EBM) to obtain more precise boundary information. Furthermore, the model introduces a boundary-guided dual-attention residual module (BDRM) for residual learning. BDRM leverages boundary information as prior knowledge and employs spatial attention to simultaneously focus on background and foreground information, in order to capture concealed details and improve segmentation accuracy. Extensive comparative experiments have been conducted on three datasets. The proposed method achieves average Dice score of 0.908 $\pm$ 0.05 and average Hausdorff distance of 3.396 $\pm$ 0.66 mm. Compared with state-of-the-art competitors, the proposed DBRN achieves better results. In addition, the average difference between the automatic measurement of AoPs based on this model and the manual measurement results is 6.157 $^{\circ }$ , which has good consistency and has broad application prospects in clinical practice.
- 11 May 2024
- Published by Elsevier in Engineering Applications of Artificial Intelligence
- Vol. 133
Dual-path multi-branch feature residual network for salient object detection
- 11 May 2024
- Published by Elsevier in Engineering Applications of Artificial Intelligence
- Vol. 133
Dual-path multi-branch feature residual network for salient object detection