Li Li
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Li Li has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
- Yuanlin Song
Shanghai Key Laboratory of Lung Inflammation and Injury, Department of Pulmonary Medicine, Zhongshan Hospital, Fudan University, Shanghai 200032, China; Shanghai Institute of Infectious Disease and Biosecurity, Fudan University, Shanghai 200032, China
3 shared publications - Fan Yang
Tsinghua University
2 shared publications - Lu Wang
Department of Pulmonary and Critical Care Medicine, Zhongshan Hospital, Fudan University, Shanghai, China
2 shared publications - Maokun Li
Tsinghua University
2 shared publications - Shenheng Xu
Tsinghua University
2 shared publications - Ying Gong
Department of Respiratory and Critical Care Medicine Zhongshan Hospital, Fudan University Shanghai China
2 shared publications
Latest Publications
- Open Access
- 25 May 2026
- Published by Springer Nature in BMC Pulmonary Medicine
- Vol. 26 (1)
Inspiratory capacity and inhalation techniques evaluated and training by digital therapy comprehensive management platform in COPD patients
Inhalation therapy is the main pharmaceutical treatment for patients with chronic obstructive pulmonary disease (COPD), but the improper selection and incorrect use of inhalation devices are widespread. The digital therapy comprehensive management platform (DT-CMP) has the potential to change this situation. The inspiratory capacity and inhalation techniques of 64 COPD patients were evaluated and trained by a DT-CMP. Moreover, 60 patients newly diagnosed with COPD and required (pressurized metered dose inhalers) pMDIs were recruited to compare the correct usage rates of inhalation devices after training through self-study based on the instructions, video teaching, and DT-CMP. Additionally, two cases of using DT-CMP for inhalation device training were described. The data indicated that peak inspiratory flow (PIF) decreased with the increase of internal resistance of inhalers and positively correlated with maximum inspiratory pressure (MIP), but no significant correlation with forced expiratory volume in one second (FEV1), forced vital capacity (FVC), FEV1% prediction and FEV1/FVC. Usage errors rate of initial evaluation of DPIs was 50%, and decreased to 16.67% after training of DT-CMP. Among these patients, 50% had insufficient effective inspiratory time, and 16.67% had insufficient inspiratory flow rate. Usage errors rate of initial evaluation of pMDIs was 75%, and decreased to 10% after training. Among these patients, 25% had hand and mouth incoordination, 70% had insufficient effective inhalation time. We also found the most frequency errors were 'sit up/stand straight & tilt head', 'breath out completely before inhalation', 'hold breath (for at least 5 s)', followed by 'hold breath' and 'hand and mouth incoordination'. And the incidence of errors in the digital therapy group was significantly lower than that in self-study group and video teaching group. The assessment of combination of checklist with DT-CMP is more comprehensive and effective than the checklist alone for evaluation and training of inspiratory capacity and inhalation techniques. DT-CMP is expected to become an important tool for assessment and training of inspiratory capacity and inhalation technique.
- 25 May 2026
- Published by Springer Nature in BMC Pulmonary Medicine
- Vol. 26 (1)
Open AccessInspiratory capacity and inhalation techniques evaluated and training by digital therapy comprehensive management platform in COPD patients
Inhalation therapy is the main pharmaceutical treatment for patients with chronic obstructive pulmonary disease (COPD), but the improper selection and incorrect use of inhalation devices are widespread. The digital therapy comprehensive management platform (DT-CMP) has the potential to change this situation. The inspiratory capacity and inhalation techniques of 64 COPD patients were evaluated and trained by a DT-CMP. Moreover, 60 patients newly diagnosed with COPD and required (pressurized metered dose inhalers) pMDIs were recruited to compare the correct usage rates of inhalation devices after training through self-study based on the instructions, video teaching, and DT-CMP. Additionally, two cases of using DT-CMP for inhalation device training were described. The data indicated that peak inspiratory flow (PIF) decreased with the increase of internal resistance of inhalers and positively correlated with maximum inspiratory pressure (MIP), but no significant correlation with forced expiratory volume in one second (FEV1), forced vital capacity (FVC), FEV1% prediction and FEV1/FVC. Usage errors rate of initial evaluation of DPIs was 50%, and decreased to 16.67% after training of DT-CMP. Among these patients, 50% had insufficient effective inspiratory time, and 16.67% had insufficient inspiratory flow rate. Usage errors rate of initial evaluation of pMDIs was 75%, and decreased to 10% after training. Among these patients, 25% had hand and mouth incoordination, 70% had insufficient effective inhalation time. We also found the most frequency errors were 'sit up/stand straight & tilt head', 'breath out completely before inhalation', 'hold breath (for at least 5 s)', followed by 'hold breath' and 'hand and mouth incoordination'. And the incidence of errors in the digital therapy group was significantly lower than that in self-study group and video teaching group. The assessment of combination of checklist with DT-CMP is more comprehensive and effective than the checklist alone for evaluation and training of inspiratory capacity and inhalation techniques. DT-CMP is expected to become an important tool for assessment and training of inspiratory capacity and inhalation technique.
- 30 October 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Biomedical and Health Informatics
- Vol. 28 (1) , 367-378
Spatio-Temporal Classification of Lung Ventilation Patterns Using 3D EIT Images: A General Approach for Individualized Lung Function Evaluation
The Pulmonary Function Test (PFT) is a widely utilized and rigorous classification test for evaluating lung function, serving as a comprehensive diagnostic tool for lung conditions. Meanwhile, Electrical Impedance Tomography (EIT) is a rapidly advancing clinical technique that visualizes conductivity distribution induced by ventilation. EIT provides additional spatial and temporal information on lung ventilation beyond traditional PFT. However, relying solely on conventional isolated interpretations of PFT results and EIT images overlooks the continuous dynamic aspects of lung ventilation. This study aims to classify lung ventilation patterns by extracting spatial and temporal features from the 3D EIT image series. The study uses a Variational Autoencoder (VAE) with a MultiRes block to compress the spatial distribution in a 3D image into a one-dimensional vector. These vectors are then stacked to create a feature map for the exhibition of temporal features. A simple convolutional neural network is used for classification. Data from 137 subjects were utilized for the training phase. Initially, the model underwent validation through a leave-one-out cross-validation process. During this validation, the model achieved an accuracy and sensitivity of 0.96 and 1.00, respectively, with an f1-score of 0.98 when identifying the normal subjects. To assess pipeline reliability and feasibility, we tested it on 9 newly recruited subjects, with accurate ventilation mode predictions for 8 out of 9. In addition, we included 2D EIT results for comparison and conducted ablation experiments to validate the effectiveness of the VAE. The study demonstrates the potential of using image series for lung ventilation mode classification, providing a feasible method for patient prescreening and presenting an alternative form of PFT.
- 30 October 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Biomedical and Health Informatics
- Vol. 28 (1) , 367-378
Spatio-Temporal Classification of Lung Ventilation Patterns Using 3D EIT Images: A General Approach for Individualized Lung Function Evaluation
The Pulmonary Function Test (PFT) is a widely utilized and rigorous classification test for evaluating lung function, serving as a comprehensive diagnostic tool for lung conditions. Meanwhile, Electrical Impedance Tomography (EIT) is a rapidly advancing clinical technique that visualizes conductivity distribution induced by ventilation. EIT provides additional spatial and temporal information on lung ventilation beyond traditional PFT. However, relying solely on conventional isolated interpretations of PFT results and EIT images overlooks the continuous dynamic aspects of lung ventilation. This study aims to classify lung ventilation patterns by extracting spatial and temporal features from the 3D EIT image series. The study uses a Variational Autoencoder (VAE) with a MultiRes block to compress the spatial distribution in a 3D image into a one-dimensional vector. These vectors are then stacked to create a feature map for the exhibition of temporal features. A simple convolutional neural network is used for classification. Data from 137 subjects were utilized for the training phase. Initially, the model underwent validation through a leave-one-out cross-validation process. During this validation, the model achieved an accuracy and sensitivity of 0.96 and 1.00, respectively, with an f1-score of 0.98 when identifying the normal subjects. To assess pipeline reliability and feasibility, we tested it on 9 newly recruited subjects, with accurate ventilation mode predictions for 8 out of 9. In addition, we included 2D EIT results for comparison and conducted ablation experiments to validate the effectiveness of the VAE. The study demonstrates the potential of using image series for lung ventilation mode classification, providing a feasible method for patient prescreening and presenting an alternative form of PFT.
- Open Access
Spatio-Temporal Classification of Lung Ventilation Patterns using 3D EIT Images: A General Approach for Individualized Lung Function Evaluation
The Pulmonary Function Test (PFT) is an widely utilized and rigorous classification test for lung function evaluation, serving as a comprehensive tool for lung diagnosis. Meanwhile, Electrical Impedance Tomography (EIT) is a rapidly advancing clinical technique that visualizes conductivity distribution induced by ventilation. EIT provides additional spatial and temporal information on lung ventilation beyond traditional PFT. However, relying solely on conventional isolated interpretations of PFT results and EIT images overlooks the continuous dynamic aspects of lung ventilation. This study aims to classify lung ventilation patterns by extracting spatial and temporal features from the 3D EIT image series. The study uses a Variational Autoencoder network with a MultiRes block to compress the spatial distribution in a 3D image into a one-dimensional vector. These vectors are then concatenated to create a feature map for the exhibition of temporal features. A simple convolutional neural network is used for classification. Data collected from 137 subjects were finally used for training. The model is validated by ten-fold and leave-one-out cross-validation first. The accuracy and sensitivity of normal ventilation mode are 0.95 and 1.00, and the f1-score is 0.94. Furthermore, we check the reliability and feasibility of the proposed pipeline by testing it on newly recruited nine subjects. Our results show that the pipeline correctly predicts the ventilation mode of 8 out of 9 subjects. The study demonstrates the potential of using image series for lung ventilation mode classification, providing a feasible method for patient prescreening and presenting an alternative form of PFT.
Open AccessSpatio-Temporal Classification of Lung Ventilation Patterns using 3D EIT Images: A General Approach for Individualized Lung Function Evaluation
The Pulmonary Function Test (PFT) is an widely utilized and rigorous classification test for lung function evaluation, serving as a comprehensive tool for lung diagnosis. Meanwhile, Electrical Impedance Tomography (EIT) is a rapidly advancing clinical technique that visualizes conductivity distribution induced by ventilation. EIT provides additional spatial and temporal information on lung ventilation beyond traditional PFT. However, relying solely on conventional isolated interpretations of PFT results and EIT images overlooks the continuous dynamic aspects of lung ventilation. This study aims to classify lung ventilation patterns by extracting spatial and temporal features from the 3D EIT image series. The study uses a Variational Autoencoder network with a MultiRes block to compress the spatial distribution in a 3D image into a one-dimensional vector. These vectors are then concatenated to create a feature map for the exhibition of temporal features. A simple convolutional neural network is used for classification. Data collected from 137 subjects were finally used for training. The model is validated by ten-fold and leave-one-out cross-validation first. The accuracy and sensitivity of normal ventilation mode are 0.95 and 1.00, and the f1-score is 0.94. Furthermore, we check the reliability and feasibility of the proposed pipeline by testing it on newly recruited nine subjects. Our results show that the pipeline correctly predicts the ventilation mode of 8 out of 9 subjects. The study demonstrates the potential of using image series for lung ventilation mode classification, providing a feasible method for patient prescreening and presenting an alternative form of PFT.