Nicola Hodson
Nicola Hodson has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Amy Findley
Adelphi Values Ltd, Patient-Centered Outcomes, Bollington, Cheshire, UK
2 shared publications - Christel Naujoks
Novartis Pharma AG, Basel, Switzerland
2 shared publications Michela Montecchi-Palmer
Novartis Pharma AG, Basel, Switzerland
2 shared publicationsPaul M. Karpecki
Kentucky Eye Institute and University of Pikeville Kentucky College of Optometry, Pikeville, USA
2 shared publicationsPaul O’bRien
Novartis Pharma AG, Basel, Switzerland
2 shared publicationsPedram Hamrah
Department of Ophthalmology, Cornea Service, New England Eye Center and Tufts Medical Center, Tufts University School of Medicine, Boston, USA
2 shared publications
Latest Publications
- Open Access
- 12 March 2025
- Published by Springer Nature in Journal of Patient-Reported Outcomes
- Vol. 9 (1) , 1-18
Psychometric validation of the Chronic Ocular Pain Questionnaire (COP-Q)
Background: The Chronic Ocular Pain Questionnaire (COP-Q) is a newly developed patient-reported outcome (PRO) measure intended to assess symptoms and impacts associated with Chronic Ocular Surface Pain (COSP). This study assessed the psychometric properties of the COP-Q to determine the adequacy of the COP-Q as a ‘fit-for-purpose’ instrument to derive trial endpoints for future clinical studies in COSP. Methods: Patients with COSP completed the COP-Q daily for four weeks on an electronic, touch-screen, tablet device as part of a longitudinal, observational study in the United States (N = 124). Analyses were conducted to assess item properties, dimensionality and scoring, reliability and validity, and interpretation of scores. In addition, 4-hour and 24-hour recall period versions of the COP-Q Symptom Module were compared. Results: Item responses were distributed across the full response scale for most COP-Q items. Inter-item correlations did not identify any redundant items (r > 0.90) and all items correlated at > 0.40 in their respective module. Confirmatory factor analysis (CFA) provided acceptable support for the unidimensional structure of the multi-item scales in the COP-Q and calculation of a total score for each module. However, CFA and Rasch analysis outlined potential redundant items for the COP-Q Visual Tasking Module (VTM), which were removed, resulting in a six-item VTM. The multi-item COP-Q modules had excellent internal consistency (α range = 0.91–0.96) and suggested fair to excellent test-retest reliability (ICC/Kappa range = 0.651–0.940) for all COP-Q modules. Construct validity for all COP-Q modules was supported by a logical pattern of correlations with concurrent measures and evidence of ability to distinguish between known-groups, with statistically significant differences between COSP severity groups. Paired t-tests, coefficient of determination (CoD) and concordance correlation coefficients (CCC) showed statistically significant differences between the two recall period versions of the Symptom Module, although the magnitude of the difference was small, and each version shares a high level of reproducibility in scores. Conclusions: Findings provide evidence that the COP-Q is a valid and reliable measure of patient-reported COSP symptoms and impacts for use in future clinical trials in COSP. Both 4-hour and 24-hour Symptom Module recall period versions are likely to yield consistent results and are equally robust.
- 12 March 2025
- Published by Springer Nature in Journal of Patient-Reported Outcomes
- Vol. 9 (1) , 1-18
Open AccessPsychometric validation of the Chronic Ocular Pain Questionnaire (COP-Q)
Background: The Chronic Ocular Pain Questionnaire (COP-Q) is a newly developed patient-reported outcome (PRO) measure intended to assess symptoms and impacts associated with Chronic Ocular Surface Pain (COSP). This study assessed the psychometric properties of the COP-Q to determine the adequacy of the COP-Q as a ‘fit-for-purpose’ instrument to derive trial endpoints for future clinical studies in COSP. Methods: Patients with COSP completed the COP-Q daily for four weeks on an electronic, touch-screen, tablet device as part of a longitudinal, observational study in the United States (N = 124). Analyses were conducted to assess item properties, dimensionality and scoring, reliability and validity, and interpretation of scores. In addition, 4-hour and 24-hour recall period versions of the COP-Q Symptom Module were compared. Results: Item responses were distributed across the full response scale for most COP-Q items. Inter-item correlations did not identify any redundant items (r > 0.90) and all items correlated at > 0.40 in their respective module. Confirmatory factor analysis (CFA) provided acceptable support for the unidimensional structure of the multi-item scales in the COP-Q and calculation of a total score for each module. However, CFA and Rasch analysis outlined potential redundant items for the COP-Q Visual Tasking Module (VTM), which were removed, resulting in a six-item VTM. The multi-item COP-Q modules had excellent internal consistency (α range = 0.91–0.96) and suggested fair to excellent test-retest reliability (ICC/Kappa range = 0.651–0.940) for all COP-Q modules. Construct validity for all COP-Q modules was supported by a logical pattern of correlations with concurrent measures and evidence of ability to distinguish between known-groups, with statistically significant differences between COSP severity groups. Paired t-tests, coefficient of determination (CoD) and concordance correlation coefficients (CCC) showed statistically significant differences between the two recall period versions of the Symptom Module, although the magnitude of the difference was small, and each version shares a high level of reproducibility in scores. Conclusions: Findings provide evidence that the COP-Q is a valid and reliable measure of patient-reported COSP symptoms and impacts for use in future clinical trials in COSP. Both 4-hour and 24-hour Symptom Module recall period versions are likely to yield consistent results and are equally robust.
- Open Access
- 6 January 2024
- Published by Springer Nature in Ophthalmology and Therapy
- Vol. 13 (2) , 615-633
Qualitative Research to Understand the Patient Experience and Evaluate Content Validity of the Chronic Ocular Pain Questionnaire (COP-Q)
Introduction Chronic ocular surface pain (COSP) is described as a persistent, moderate-to-severe pain at the ocular surface lasting more than 3 months. Symptoms of COSP have a significant impact on patients’ vision-dependent activities of daily living (ADL) and distal health-related quality of life (HRQoL). To adequately capture patient perspectives in clinical trials, patient-reported outcome (PRO) measures must demonstrate sufficient evidence of content validity in the target population. This study aimed to explore the patient experience of living with COSP and evaluate content validity of the newly developed Chronic Ocular Pain Questionnaire (COP-Q) for use in COSP clinical trials. Methods Qualitative, combined concept elicitation (CE) and cognitive debriefing (CD) interviews were conducted with 24 patients experiencing COSP symptoms in the USA. Interviews were supplemented with real-time data collection via a daily diary app task in a subset of patients (n = 15) to explore the day-to-day patient experience. Three healthcare professionals (HCPs) from the USA, Canada, and France were also interviewed to provide a clinical perspective. CE results were used to further inform development of a conceptual model and to refine PRO items/response options. CD interviews assessed relevance and understanding of the COP-Q. Interviews were conducted across multiple rounds to allow item modifications and subsequent testing. Results Eye pain, eye itch, burning sensation, eye dryness, eye irritation, foreign body sensation, eye fatigue, and eye grittiness were the most frequently reported symptoms impacting vision-dependent ADL (e.g., reading, using digital devices, driving) and wider HRQoL (e.g., emotional wellbeing, social functioning, work). COP-Q instructions, items, and response scales were understood, and concepts were considered relevant. Feedback supported modifications to instruction/item wording and confirmed the most appropriate recall periods. Conclusions Findings support content validity of the COP-Q for use in COSP populations. Ongoing research to evaluate psychometric validity of the COP-Q will support future use of the instrument in clinical trial efficacy endpoints.
- 6 January 2024
- Published by Springer Nature in Ophthalmology and Therapy
- Vol. 13 (2) , 615-633
Open AccessQualitative Research to Understand the Patient Experience and Evaluate Content Validity of the Chronic Ocular Pain Questionnaire (COP-Q)
Introduction Chronic ocular surface pain (COSP) is described as a persistent, moderate-to-severe pain at the ocular surface lasting more than 3 months. Symptoms of COSP have a significant impact on patients’ vision-dependent activities of daily living (ADL) and distal health-related quality of life (HRQoL). To adequately capture patient perspectives in clinical trials, patient-reported outcome (PRO) measures must demonstrate sufficient evidence of content validity in the target population. This study aimed to explore the patient experience of living with COSP and evaluate content validity of the newly developed Chronic Ocular Pain Questionnaire (COP-Q) for use in COSP clinical trials. Methods Qualitative, combined concept elicitation (CE) and cognitive debriefing (CD) interviews were conducted with 24 patients experiencing COSP symptoms in the USA. Interviews were supplemented with real-time data collection via a daily diary app task in a subset of patients (n = 15) to explore the day-to-day patient experience. Three healthcare professionals (HCPs) from the USA, Canada, and France were also interviewed to provide a clinical perspective. CE results were used to further inform development of a conceptual model and to refine PRO items/response options. CD interviews assessed relevance and understanding of the COP-Q. Interviews were conducted across multiple rounds to allow item modifications and subsequent testing. Results Eye pain, eye itch, burning sensation, eye dryness, eye irritation, foreign body sensation, eye fatigue, and eye grittiness were the most frequently reported symptoms impacting vision-dependent ADL (e.g., reading, using digital devices, driving) and wider HRQoL (e.g., emotional wellbeing, social functioning, work). COP-Q instructions, items, and response scales were understood, and concepts were considered relevant. Feedback supported modifications to instruction/item wording and confirmed the most appropriate recall periods. Conclusions Findings support content validity of the COP-Q for use in COSP populations. Ongoing research to evaluate psychometric validity of the COP-Q will support future use of the instrument in clinical trial efficacy endpoints.