JSJana Schreuder

Jana Schreuder

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Jana Schreuder has a total of 15 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Distinction between Listeria species and L. monocytogenes serotypes with a handheld, VNIR hyperspectral imaging camera

    by Jana Schreuder, Diane Rip, Paul James Williams

    A handheld, visible near-infrared (VNIR) hyperspectral imaging (HSI) camera was used to differentiate between Listeria species ( L. monocytogenes , L. ivanovii and L. innocua ) and two L. monocytogenes serotypes: 1/2a and 4b. The results indicated that portable HSI cameras could effectively be used for pathogen detection and distinction applications, despite lower spectral resolution and higher sensitivity to noise when compared to benchtop CCD-based instruments. Five hundred and fifty-five hyperspectral images were collected from pure cultures on agar plates throughout seven sampling campaigns. Sixty-five percent of samples/isolates ( n =± 90 samples per class) were used to train Partial Least Squares Discriminant Analysis (PLS-DA) models and 35% of samples ( n =± 50 samples per class) were used for validation. An overall classification accuracy (validation) of 74.5% was achieved for species-level discrimination through a four-class model ( L. monocytogenes 1/2a, L. monocytogenes 4b, L. ivanovii and L. innocua ), which demonstrates moderate performance within the VNIR range. However, Species-level performance was uneven across classes, with lower validation accuracies for L. innocua (68.0%) and L. ivanovii (63.0%) compared to L. monocytogenes 1/2a (71.8%) and 4b (95.2%). In contrast, a two-class model achieved ~ 90% accuracy for serotype-level discrimination between L. monocytogenes serotypes 1/2a and 4b. This highlights a novel use of portable VNIR cameras as a rapid, non-destructive serotyping aid. Variable Importance in Projection (VIP) score plots were used to characterise valuable wavelengths in the visible range that were significant for discriminant analysis, for example, 690 nm was significant for the classification of L. innocua , whilst 871 nm was associated with L. ivanovii. Notably, all the significant absorption regions used to differentiate between the L. monocytogenes serotypes were in the visible range (480–525 nm, 540–560 nm, 610 nm and 690 nm) despite the colony morphology being virtually identical for these organisms on brain heart infusion agar. Key points: • A portable HSI camera was used to distinguish between Listeria colonies on agar • PLS-DA accuracy of 74.5% was obtained for classification between Listeria species • PLS-DA accuracy of 90% obtained for classification between L. monocytogenes serotypes

  • Open Access

    Predicting Egg Storage Time with a Portable Near-Infrared Instrument: Effects of Temperature and Production System

    by Daniel Cozzolino, Pooja Sanal, Jana Schreuder, Paul James Williams, Elham Assadi Soumeh, Milou Helene Dekkers, Molly Anderson, Sheree Boisen, Louwrens Christiaan Hoffman

    Determining egg freshness is critical for ensuring food safety and security and as such, different methods have been evaluated and implemented to accurately measure and predict it. In this study, a portable near-infrared (NIR) instrument combined with chemometrics was used to monitor and predict the storage time of eggs under two storage conditions—room temperature (RT) and cold (CT) storage—from two production systems: cage and free-range. A total of 700 egg samples were analyzed, using principal component analysis (PCA) and partial least squares (PLS) regression to analyze the NIR spectra. The PCA score plot did not show any clear separation between egg samples from the two production systems; however, some egg samples were grouped according to storage conditions. The cross-validation statistics for predicting storage time were as follows: for cage and RT eggs, the coefficient of determination in cross validation (R2CV) was 0.67, with a standard error in cross-validation (SECV) of 7.64 days and residual predictive deviation (RPD) of 1.8; for CT cage eggs, R2CV of 0.84, SECV of 5.38 days and RPD of 3.2; for CT free-range eggs, R2CV of 0.83, SECV of 5.52 days and RPD of 3.2; and for RT free-range eggs, R2CV of 0.82, SECV of 5.61 days, and RPD of 3.0. This study demonstrated that NIR spectroscopy can predict storage time non-destructively in intact egg samples. Even though the results of the present study are promising, further research is still needed to further extend these results to other production systems, as well as to explore the potential of this technique to predict other egg quality parameters associated with freshness.