Fiorella Anna Lombardi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Fiorella Anna Lombardi has a total of 24 co-authors. Here are the top co-authors by number of shared publications:
- Angelo Fassio
Rheumatology Unit, Department of Medicine, University of Verona, Verona, Italy
1 shared publication - Angelo Vacca
Department of Precision and Regenerative Medicine and Ionian Area, UOC Medicina Interna “Guido Baccelli”, University of Bari Aldo Moro, Policlinico, 70126 Bari, Italy
1 shared publication - Antonio Giovanni Solimando
Department of Precision and Regenerative Medicine and Ionian Area - DiMePRe-J, Guido Baccelli Unit of Internal Medicine, School of Medicine, University of Bari Aldo Moro, Bari, Italy
1 shared publication - Chiara Caletti
Nephrology Unit, University of Verona, 37134 Verona, Italy
1 shared publication - Claudia Maria Morelli
Unit of Internal Medicine “G. Baccelli”, Department of Precision and Regenerative Medicine and Ionian Area (DiMePRe-J), University of Bari Aldo Moro Medical School, 70124 Bari, Italy
1 shared publication - Davide Gatti
Rheumatology Unit, Department of Medicine, University of Verona, Verona, Italy
1 shared publication
Latest Publications
- Open Access
- 23 September 2024
- Published by MDPI AG in Diagnostics
- Vol. 14 (18) , 2106
Radiofrequency Echographic Multi Spectrometry (REMS) Technology for Bone Health Status Evaluation in Kidney Transplant Recipients
Background: A significant loss in bone density and strength occurs during the post-renal-transplant period with higher susceptibility to fracture. The study aims to compare the performance of the Radiofrequency Echographic Multi Spectrometry (REMS) in the bone mineral density assessment with the conventional dual-energy X-ray absorptiometry (DXA) in a cohort of kidney transplant recipients (KTR). Methods: A cohort of 40 patients underwent both DXA and REMS examinations on the lumbar spine and/or proximal femur. The paired t-test was used to compare DXA and REMS measurements; the chi-square test was used to compare the prevalence of osteoporosis/osteopenia. The agreement between the two techniques was assessed through Spearman’s correlation. Results: As expected, most KTR patients were osteopenic or osteoporotic with both REMS and DXA (86.5% and 81% for the femur; 88% and 65% for the lumbar spine p < 0.05). A modest correlation (r = 0.4, p < 0.01) was observed at the lumbar spine between the T-score measured by REMS and DXA. A strong correlation was defined between REMS and DXA in the femoral region (r = 0.7, p < 0.0001). Conclusions: The study demonstrates the exchangeability of the two techniques on the proximal femur in KTR and a higher diagnostic accuracy of REMS at the spine level than DXA.
- 23 September 2024
- Published by MDPI AG in Diagnostics
- Vol. 14 (18) , 2106
Open AccessRadiofrequency Echographic Multi Spectrometry (REMS) Technology for Bone Health Status Evaluation in Kidney Transplant Recipients
Background: A significant loss in bone density and strength occurs during the post-renal-transplant period with higher susceptibility to fracture. The study aims to compare the performance of the Radiofrequency Echographic Multi Spectrometry (REMS) in the bone mineral density assessment with the conventional dual-energy X-ray absorptiometry (DXA) in a cohort of kidney transplant recipients (KTR). Methods: A cohort of 40 patients underwent both DXA and REMS examinations on the lumbar spine and/or proximal femur. The paired t-test was used to compare DXA and REMS measurements; the chi-square test was used to compare the prevalence of osteoporosis/osteopenia. The agreement between the two techniques was assessed through Spearman’s correlation. Results: As expected, most KTR patients were osteopenic or osteoporotic with both REMS and DXA (86.5% and 81% for the femur; 88% and 65% for the lumbar spine p < 0.05). A modest correlation (r = 0.4, p < 0.01) was observed at the lumbar spine between the T-score measured by REMS and DXA. A strong correlation was defined between REMS and DXA in the femoral region (r = 0.7, p < 0.0001). Conclusions: The study demonstrates the exchangeability of the two techniques on the proximal femur in KTR and a higher diagnostic accuracy of REMS at the spine level than DXA.
- Open Access
- 10 January 2024
- Published by MDPI AG in Diagnostics
- Vol. 14 (2) , 155
A Novel Automatic Algorithm to Support Lung Ultrasound Non-Expert Physicians in Interstitial Pneumonia Evaluation: A Single-Center Study
Introduction: Lung ultrasound (LUS) is widely used in clinical practice for identifying interstitial lung diseases (ILDs) and assessing their progression. Although high-resolution computed tomography (HRCT) remains the gold standard for evaluating the severity of ILDs, LUS can be performed as a screening method or as a follow-up tool post-HRCT. Minimum training is needed to better identify typical lesions, and the integration of innovative artificial intelligence (AI) automatic algorithms may enhance diagnostic efficiency. Aim: This study aims to assess the effectiveness of a novel AI algorithm in automatic ILD recognition and scoring in comparison to an expert LUS sonographer. The “SensUS Lung” device, equipped with an automatic algorithm, was employed for the automatic recognition of the typical ILD patterns and to calculate an index grading of the interstitial involvement. Methods: We selected 33 Caucasian patients in follow-up for ILDs exhibiting typical HRCT patterns (honeycombing, ground glass, fibrosis). An expert physician evaluated all patients with LUS on twelve segments (six per side). Next, blinded to the previous evaluation, an untrained operator, a non-expert in LUS, performed the exam with the SensUS device equipped with the automatic algorithm (“SensUS Lung”) using the same protocol. Pulmonary functional tests (PFT) and DLCO were conducted for all patients, categorizing them as having reduced or preserved DLCO. The SensUS device indicated different grades of interstitial involvement named Lung Staging that were scored from 0 (absent) to 4 (peak), which was compared to the Lung Ultrasound Score (LUS score) by dividing it by the number of segments evaluated. Statistical analyses were done with Wilcoxon tests for paired values or Mann–Whitney for unpaired samples, and correlations were performed using Spearman analysis; p < 0.05 was considered significant. Results: Lung Staging was non-inferior to LUS score in identifying the risk of ILDs (median SensUS 1 [0–2] vs. LUS 0.67 [0.25–1.54]; p = 0.84). Furthermore, the grade of interstitial pulmonary involvement detected with the SensUS device is directly related to the LUS score (r = 0.607, p = 0.002). Lung Staging values were inversely correlated with forced expiratory volume at first second (FEV1%, r = −0.40, p = 0.027), forced vital capacity (FVC%, r = −0.39, p = 0.03) and forced expiratory flow (FEF) at 25th percentile (FEF25%, r = −0.39, p = 0.02) while results directly correlated with FEF25–75% (r = 0.45, p = 0.04) and FEF75% (r = 0.43, p = 0.01). Finally, in patients with reduced DLCO, the Lung Staging was significantly higher, overlapping the LUS (reduced median 1 [1–2] vs. preserved 0 [0–1], p = 0.001), and overlapping the LUS (reduced median 18 [4–20] vs. preserved 5.5 [2–9], p = 0.035). Conclusions: Our data suggest that the considered AI automatic algorithm may assist non-expert physicians in LUS, resulting in non-inferior-to-expert LUS despite a tendency to overestimate ILD lesions. Therefore, the AI algorithm has the potential to support physicians, particularly non-expert LUS sonographers, in daily clinical practice to monitor patients with ILDs. The adopted device is user-friendly, offering a fully automatic real-time analysis. However, it needs proper training in basic skills.
- 10 January 2024
- Published by MDPI AG in Diagnostics
- Vol. 14 (2) , 155
Open AccessA Novel Automatic Algorithm to Support Lung Ultrasound Non-Expert Physicians in Interstitial Pneumonia Evaluation: A Single-Center Study
Introduction: Lung ultrasound (LUS) is widely used in clinical practice for identifying interstitial lung diseases (ILDs) and assessing their progression. Although high-resolution computed tomography (HRCT) remains the gold standard for evaluating the severity of ILDs, LUS can be performed as a screening method or as a follow-up tool post-HRCT. Minimum training is needed to better identify typical lesions, and the integration of innovative artificial intelligence (AI) automatic algorithms may enhance diagnostic efficiency. Aim: This study aims to assess the effectiveness of a novel AI algorithm in automatic ILD recognition and scoring in comparison to an expert LUS sonographer. The “SensUS Lung” device, equipped with an automatic algorithm, was employed for the automatic recognition of the typical ILD patterns and to calculate an index grading of the interstitial involvement. Methods: We selected 33 Caucasian patients in follow-up for ILDs exhibiting typical HRCT patterns (honeycombing, ground glass, fibrosis). An expert physician evaluated all patients with LUS on twelve segments (six per side). Next, blinded to the previous evaluation, an untrained operator, a non-expert in LUS, performed the exam with the SensUS device equipped with the automatic algorithm (“SensUS Lung”) using the same protocol. Pulmonary functional tests (PFT) and DLCO were conducted for all patients, categorizing them as having reduced or preserved DLCO. The SensUS device indicated different grades of interstitial involvement named Lung Staging that were scored from 0 (absent) to 4 (peak), which was compared to the Lung Ultrasound Score (LUS score) by dividing it by the number of segments evaluated. Statistical analyses were done with Wilcoxon tests for paired values or Mann–Whitney for unpaired samples, and correlations were performed using Spearman analysis; p < 0.05 was considered significant. Results: Lung Staging was non-inferior to LUS score in identifying the risk of ILDs (median SensUS 1 [0–2] vs. LUS 0.67 [0.25–1.54]; p = 0.84). Furthermore, the grade of interstitial pulmonary involvement detected with the SensUS device is directly related to the LUS score (r = 0.607, p = 0.002). Lung Staging values were inversely correlated with forced expiratory volume at first second (FEV1%, r = −0.40, p = 0.027), forced vital capacity (FVC%, r = −0.39, p = 0.03) and forced expiratory flow (FEF) at 25th percentile (FEF25%, r = −0.39, p = 0.02) while results directly correlated with FEF25–75% (r = 0.45, p = 0.04) and FEF75% (r = 0.43, p = 0.01). Finally, in patients with reduced DLCO, the Lung Staging was significantly higher, overlapping the LUS (reduced median 1 [1–2] vs. preserved 0 [0–1], p = 0.001), and overlapping the LUS (reduced median 18 [4–20] vs. preserved 5.5 [2–9], p = 0.035). Conclusions: Our data suggest that the considered AI automatic algorithm may assist non-expert physicians in LUS, resulting in non-inferior-to-expert LUS despite a tendency to overestimate ILD lesions. Therefore, the AI algorithm has the potential to support physicians, particularly non-expert LUS sonographers, in daily clinical practice to monitor patients with ILDs. The adopted device is user-friendly, offering a fully automatic real-time analysis. However, it needs proper training in basic skills.