Sylwia M. Kolenderska
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Sylwia M. Kolenderska has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
Piotr Kolenderski
Institute of Physics, Faculty of Physics, Astronomy and Informatics, Nicolaus Copernicus University in Torun, Torun, Poland
6 shared publicationsKrzysztof A. Maliszewski
School of Mathematics and Statistics, University of Canterbury, Christchurch, New Zealand
3 shared publicationsVarvara Vetrova
School of Mathematics and Statistics, University of Canterbury, Christchurch, New Zealand
3 shared publicationsFrederique Vanholsbeeck
The Department of Physics The University of Auckland 1010 Auckland New Zealand
2 shared publications- Maciej Szkulmowski
Nicolaus Copernicus University in Torun
2 shared publications - Piotr Kolenderski
Nicolaus Copernicus University in Torun
2 shared publications
Latest Publications
- Open Access
- 29 July 2026
- Published by Springer Nature in Scientific Reports
- Vol. 16 (1)
Fast and dispersion-controllable quantum imaging with Fourier-domain Quantum Optical Coherence Tomography
- 29 July 2026
- Published by Springer Nature in Scientific Reports
- Vol. 16 (1)
Open AccessFast and dispersion-controllable quantum imaging with Fourier-domain Quantum Optical Coherence Tomography
- Open Access
Selective nonlinearities removal from digital signals
Many instruments performing optical and non-optical imaging and sensing, such as Optical Coherence Tomography (OCT), Magnetic Resonance Imaging or Fourier-transform spectrometry, produce digital signals containing modulations, sine-like components, which only after Fourier transformation give information about the structure or characteristics of the investigated object. Due to the fundamental physics-related limitations of such methods, the distribution of these signal components is often nonlinear and, when not properly compensated, leads to the resolution, precision or quality drop in the final image. Here, we propose an innovative approach that has the potential to allow cleaning of the signal from the nonlinearities but most of all, it now allows to switch the given order off, leaving all others intact. The latter provides a tool for more in-depth analysis of the nonlinearity-inducing properties of the investigated object, which can lead to applications in early disease detection or more sensitive sensing of chemical compounds. We consider OCT signals and nonlinearities up to the third order. In our approach, we propose two neural networks: one to remove solely the second-order nonlinearity and the other for removing solely the third-order nonlinearity. The input of the networks is a novel two-dimensional data structure with all the information needed for the network to infer a nonlinearity-free signal. We describe the developed networks and present the results for second-order and third-order nonlinearity removal in OCT data representing the images of various objects: a mirror, glass, and fruits.
Open AccessSelective nonlinearities removal from digital signals
Many instruments performing optical and non-optical imaging and sensing, such as Optical Coherence Tomography (OCT), Magnetic Resonance Imaging or Fourier-transform spectrometry, produce digital signals containing modulations, sine-like components, which only after Fourier transformation give information about the structure or characteristics of the investigated object. Due to the fundamental physics-related limitations of such methods, the distribution of these signal components is often nonlinear and, when not properly compensated, leads to the resolution, precision or quality drop in the final image. Here, we propose an innovative approach that has the potential to allow cleaning of the signal from the nonlinearities but most of all, it now allows to switch the given order off, leaving all others intact. The latter provides a tool for more in-depth analysis of the nonlinearity-inducing properties of the investigated object, which can lead to applications in early disease detection or more sensitive sensing of chemical compounds. We consider OCT signals and nonlinearities up to the third order. In our approach, we propose two neural networks: one to remove solely the second-order nonlinearity and the other for removing solely the third-order nonlinearity. The input of the networks is a novel two-dimensional data structure with all the information needed for the network to infer a nonlinearity-free signal. We describe the developed networks and present the results for second-order and third-order nonlinearity removal in OCT data representing the images of various objects: a mirror, glass, and fruits.
- 8 January 2024
- Published by Optica Publishing Group in Optics Letters
- Vol. 49 (2) , 363-366
Quantum-inspired optical coherence tomography using classical light in a single-photon counting regime
Quantum optical coherence tomography (Q-OCT) presents many advantages over its classical counterpart, optical coherence tomography (OCT), provides an increased axial resolution, and is immune to even orders of dispersion. The core of Q-OCT is the quantum interference of negatively correlated entangled photon pairs which, in the Fourier domain, are observed by means of a joint spectrum measurement. In this work, we explore the use of a spectral approach in a novel configuration where classical light pulses are employed instead of entangled photons. The intensity of these light pulses is reduced to a single photon level. We report theoretical analysis along with its experimental validation to show that although such a classical light is much easier to launch into an experimental system, it offers limited benefits compared to Q-OCT based on the entangled light. We analyze the differences in the characteristics of the joint spectrum obtained with entangled photons and with classical optical pulses and point out to the differences’ source: the lack of the advantage-bringing term in the signal.
- 8 January 2024
- Published by Optica Publishing Group in Optics Letters
- Vol. 49 (2) , 363-366
Quantum-inspired optical coherence tomography using classical light in a single-photon counting regime
Quantum optical coherence tomography (Q-OCT) presents many advantages over its classical counterpart, optical coherence tomography (OCT), provides an increased axial resolution, and is immune to even orders of dispersion. The core of Q-OCT is the quantum interference of negatively correlated entangled photon pairs which, in the Fourier domain, are observed by means of a joint spectrum measurement. In this work, we explore the use of a spectral approach in a novel configuration where classical light pulses are employed instead of entangled photons. The intensity of these light pulses is reduced to a single photon level. We report theoretical analysis along with its experimental validation to show that although such a classical light is much easier to launch into an experimental system, it offers limited benefits compared to Q-OCT based on the entangled light. We analyze the differences in the characteristics of the joint spectrum obtained with entangled photons and with classical optical pulses and point out to the differences’ source: the lack of the advantage-bringing term in the signal.
- Open Access
- 22 April 2023
- Published by Springer Nature in Scientific Reports
- Vol. 13 (1) , 1-10
Extracting Group Velocity Dispersion values using quantum-mimic Optical Coherence Tomography and Machine Learning
Quantum-mimic Optical Coherence Tomography (Qm-OCT) images are cluttered with artefacts - parasitic peaks which emerge as a by-product of the algorithm used in this method. However, the shape and behaviour of an artefact are uniquely related to Group Velocity Dispersion (GVD) of the layer this artefact corresponds to and consequently, the GVD values can be inferred by carefully analysing them. Since for multi-layered objects the number of artefacts is too high to enable layer-specific analysis, we employ a solution based on Machine Learning. We train a neural network with Qm-OCT data as an input and dispersion profiles, i.e. depth distribution of GVD within an A-scan, as an output. By accounting for noise during training, we process experimental data and estimate the GVD values of BK7 and sapphire as well as provide a qualitative GVD value distribution in a grape and cucumber. Compared to other GVD-retrieving methods, our solution does not require user input, automatically provides dispersion values for all the visualised layers and is scalable. We analyse the factors affecting the accuracy of determining GVD: noise in the experimental data as well as general physical limitations of the detection of GVD-induced changes, and suggest possible solutions.
- 22 April 2023
- Published by Springer Nature in Scientific Reports
- Vol. 13 (1) , 1-10
Open AccessExtracting Group Velocity Dispersion values using quantum-mimic Optical Coherence Tomography and Machine Learning
Quantum-mimic Optical Coherence Tomography (Qm-OCT) images are cluttered with artefacts - parasitic peaks which emerge as a by-product of the algorithm used in this method. However, the shape and behaviour of an artefact are uniquely related to Group Velocity Dispersion (GVD) of the layer this artefact corresponds to and consequently, the GVD values can be inferred by carefully analysing them. Since for multi-layered objects the number of artefacts is too high to enable layer-specific analysis, we employ a solution based on Machine Learning. We train a neural network with Qm-OCT data as an input and dispersion profiles, i.e. depth distribution of GVD within an A-scan, as an output. By accounting for noise during training, we process experimental data and estimate the GVD values of BK7 and sapphire as well as provide a qualitative GVD value distribution in a grape and cucumber. Compared to other GVD-retrieving methods, our solution does not require user input, automatically provides dispersion values for all the visualised layers and is scalable. We analyse the factors affecting the accuracy of determining GVD: noise in the experimental data as well as general physical limitations of the detection of GVD-induced changes, and suggest possible solutions.
- 1 December 2022
- Published by Optica Publishing Group in Optics Express
- Vol. 30 (25) , 45624-45634
Towards retrieving dispersion profiles using quantum-mimic optical coherence tomography and machine learning
Artefacts in quantum-mimic optical coherence tomography are considered detrimental because they scramble the images even for the simplest objects. They are a side effect of autocorrelation, which is used in the quantum entanglement mimicking algorithm behind this method. Interestingly, the autocorrelation imprints certain characteristics onto an artefact – it makes its shape and characteristics depend on the amount of dispersion exhibited by the layer that artefact corresponds to. In our method, a neural network learns the unique relationship between the artefacts’ shape and GVD, and consequently, it is able to provide a good qualitative representation of object’s dispersion profile for never-seen-before data: computer-generated single dispersive layers and experimental pieces of glass. We show that the autocorrelation peaks – additional peaks in the A-scan appearing due to the interference of light reflected from the object – affect the GVD profiles. Through relevant calculations, simulations and experimental testing, the mechanism leading to the observed GVD changes is identified and explained. Finally, the network performance is tested in the presence of noise in the data and with the experimental data representing single layers of quartz, sapphire and BK7.
- 1 December 2022
- Published by Optica Publishing Group in Optics Express
- Vol. 30 (25) , 45624-45634
Towards retrieving dispersion profiles using quantum-mimic optical coherence tomography and machine learning
Artefacts in quantum-mimic optical coherence tomography are considered detrimental because they scramble the images even for the simplest objects. They are a side effect of autocorrelation, which is used in the quantum entanglement mimicking algorithm behind this method. Interestingly, the autocorrelation imprints certain characteristics onto an artefact – it makes its shape and characteristics depend on the amount of dispersion exhibited by the layer that artefact corresponds to. In our method, a neural network learns the unique relationship between the artefacts’ shape and GVD, and consequently, it is able to provide a good qualitative representation of object’s dispersion profile for never-seen-before data: computer-generated single dispersive layers and experimental pieces of glass. We show that the autocorrelation peaks – additional peaks in the A-scan appearing due to the interference of light reflected from the object – affect the GVD profiles. Through relevant calculations, simulations and experimental testing, the mechanism leading to the observed GVD changes is identified and explained. Finally, the network performance is tested in the presence of noise in the data and with the experimental data representing single layers of quartz, sapphire and BK7.
- Open Access
Towards retrieving dispersion profiles using quantum-mimic Optical Coherence Tomography and Machine Learnin
Artefacts in quantum-mimic Optical Coherence Tomography are considered detrimental because they scramble the images even for the simplest objects. They are a side effect of autocorrelation which is used in the quantum entanglement mimicking algorithm behind this method. Interestingly, the autocorrelation imprints certain characteristics onto an artefact - it makes its shape and characteristics depend on the amount of dispersion exhibited by the layer that artefact corresponds to. This unique relationship between the artefact and the layer's dispersion can be used to determine Group Velocity Dispersion (GVD) values of object layers and, based on them, build a dispersion-contrasted depth profile. The retrieval of GVD profiles is achieved via Machine Learning. During training, a neural network learns the relationship between GVD and the artefacts' shape and characteristics, and consequently, it is able to provide a good qualitative representation of object's dispersion profile for never-seen-before data: computer-generated single dispersive layers and experimental pieces of glass.
Open AccessTowards retrieving dispersion profiles using quantum-mimic Optical Coherence Tomography and Machine Learnin
Artefacts in quantum-mimic Optical Coherence Tomography are considered detrimental because they scramble the images even for the simplest objects. They are a side effect of autocorrelation which is used in the quantum entanglement mimicking algorithm behind this method. Interestingly, the autocorrelation imprints certain characteristics onto an artefact - it makes its shape and characteristics depend on the amount of dispersion exhibited by the layer that artefact corresponds to. This unique relationship between the artefact and the layer's dispersion can be used to determine Group Velocity Dispersion (GVD) values of object layers and, based on them, build a dispersion-contrasted depth profile. The retrieval of GVD profiles is achieved via Machine Learning. During training, a neural network learns the relationship between GVD and the artefacts' shape and characteristics, and consequently, it is able to provide a good qualitative representation of object's dispersion profile for never-seen-before data: computer-generated single dispersive layers and experimental pieces of glass.
- Open Access
- 20 September 2021
- Published by Springer Nature in Scientific Reports
- Vol. 11 (1) , 1-8
Artefact-removal algorithms for Fourier domain quantum optical coherence tomography
Quantum Optical Coherence Tomography (Q-OCT) is a non-classical equivalent of Optical Coherence Tomography and is able to provide a twofold axial resolution increase and immunity to resolution-degrading dispersion. The main drawback of Q-OCT are artefacts which are additional elements that clutter an A-scan and lead to a complete loss of structural information for multilayered objects. Whereas there are very practical and successful methods for artefact removal in Time-domain Q-OCT, no such scheme has been devised for Fourier-domain Q-OCT (Fd-Q-OCT), although the latter modality—through joint spectrum detection—outputs a lot of useful information on both the system and the imaged object. Here, we propose two algorithms which process a Fd-Q-OCT joint spectrum into an artefact-free A-scan. We present the theoretical background of these algorithms and show their performance on computer-generated data. The limitations of both algorithms with regards to the experimental system and the imaged object are discussed.
- 20 September 2021
- Published by Springer Nature in Scientific Reports
- Vol. 11 (1) , 1-8
Open AccessArtefact-removal algorithms for Fourier domain quantum optical coherence tomography
Quantum Optical Coherence Tomography (Q-OCT) is a non-classical equivalent of Optical Coherence Tomography and is able to provide a twofold axial resolution increase and immunity to resolution-degrading dispersion. The main drawback of Q-OCT are artefacts which are additional elements that clutter an A-scan and lead to a complete loss of structural information for multilayered objects. Whereas there are very practical and successful methods for artefact removal in Time-domain Q-OCT, no such scheme has been devised for Fourier-domain Q-OCT (Fd-Q-OCT), although the latter modality—through joint spectrum detection—outputs a lot of useful information on both the system and the imaged object. Here, we propose two algorithms which process a Fd-Q-OCT joint spectrum into an artefact-free A-scan. We present the theoretical background of these algorithms and show their performance on computer-generated data. The limitations of both algorithms with regards to the experimental system and the imaged object are discussed.
- Open Access
- 31 May 2021
- Published by Springer Nature in Scientific Reports
- Vol. 11 (1) , 1-10
Intensity correlation OCT is a classical mimic of quantum OCT providing up to twofold resolution improvement
Quantum Optical Coherence Tomography (Q-OCT) uses quantum properties of light to provide several advantages over its classical counterpart, OCT: it achieves a twice better axial resolution with the same spectral bandwidth and it is immune to even orders of dispersion. Since these features are very sought-after in OCT imaging, many hardware and software techniques have been created to mimic the quantum behaviour of light and achieve these features using traditional OCT systems. The most recent, purely algorithmic scheme—an improved version of Intensity Correlation Spectral Domain OCT named ICA-SD-OCT—showed even-order dispersion cancellation and reduction of artefacts. The true capabilities of this method were unfortunately severely undermined, both in terms of its relation to Q-OCT and its main performance parameters. In this work, we provide experimental demonstrations as well as numerical and analytical arguments to show that ICA-SD-OCT is a true classical equivalent of Q-OCT, more specifically its Fourier domain version, and therefore it enables a true two-fold axial resolution improvement. We believe that clarification of all the misconceptions about this very promising algorithm will highlight the great value of this method for OCT and consequently lead to its practical applications for resolution- and quality-enhanced OCT imaging.
- 31 May 2021
- Published by Springer Nature in Scientific Reports
- Vol. 11 (1) , 1-10
Open AccessIntensity correlation OCT is a classical mimic of quantum OCT providing up to twofold resolution improvement
Quantum Optical Coherence Tomography (Q-OCT) uses quantum properties of light to provide several advantages over its classical counterpart, OCT: it achieves a twice better axial resolution with the same spectral bandwidth and it is immune to even orders of dispersion. Since these features are very sought-after in OCT imaging, many hardware and software techniques have been created to mimic the quantum behaviour of light and achieve these features using traditional OCT systems. The most recent, purely algorithmic scheme—an improved version of Intensity Correlation Spectral Domain OCT named ICA-SD-OCT—showed even-order dispersion cancellation and reduction of artefacts. The true capabilities of this method were unfortunately severely undermined, both in terms of its relation to Q-OCT and its main performance parameters. In this work, we provide experimental demonstrations as well as numerical and analytical arguments to show that ICA-SD-OCT is a true classical equivalent of Q-OCT, more specifically its Fourier domain version, and therefore it enables a true two-fold axial resolution improvement. We believe that clarification of all the misconceptions about this very promising algorithm will highlight the great value of this method for OCT and consequently lead to its practical applications for resolution- and quality-enhanced OCT imaging.
- Open Access
Artefact-removal algorithms for Fourier domain Quantum Optical Coherence Tomography
Quantum Optical Coherence Tomography (Q-OCT) is a non-classical equivalent of Optical Coherence Tomography and is able to provide a twofold axial resolution increase and immunity to resolution-degrading dispersion. The main drawback of Q-OCT are artefacts which are additional elements that clutter an A-scan and lead to a complete loss of structural information for multilayered objects. Whereas there are successful methods for artefact removal in Time-domain Q-OCT, no such scheme has been devised for Fourier-domain Q-OCT (Fd-Q-OCT), although the latter modality - through joint spectrum detection - outputs a lot of useful information on both the system and the imaged object. Here, we propose two algorithms which process a Fd-Q-OCT's joint spectrum into an artefact-free A-scan. We present the theoretical background of these algorithms and show their performance on computer-generated data. The limitations of both algorithms with regards to the experimental system and the imaged object are discussed.
Open AccessArtefact-removal algorithms for Fourier domain Quantum Optical Coherence Tomography
Quantum Optical Coherence Tomography (Q-OCT) is a non-classical equivalent of Optical Coherence Tomography and is able to provide a twofold axial resolution increase and immunity to resolution-degrading dispersion. The main drawback of Q-OCT are artefacts which are additional elements that clutter an A-scan and lead to a complete loss of structural information for multilayered objects. Whereas there are successful methods for artefact removal in Time-domain Q-OCT, no such scheme has been devised for Fourier-domain Q-OCT (Fd-Q-OCT), although the latter modality - through joint spectrum detection - outputs a lot of useful information on both the system and the imaged object. Here, we propose two algorithms which process a Fd-Q-OCT's joint spectrum into an artefact-free A-scan. We present the theoretical background of these algorithms and show their performance on computer-generated data. The limitations of both algorithms with regards to the experimental system and the imaged object are discussed.
- Open Access
Quantum Optical Coherence Tomography using two photon joint spectrum detection (JS-Q-OCT)
Quantum Optical Coherence Tomography (Q-OCT) is the non-classical counterpart of Optical Coherence Tomography (OCT) - a high-resolution 3D imaging technique based on white-light interferometry. Because Q-OCT uses a source of frequency-entangled photon pairs, not only is the axial resolution not affected by dispersion mismatch in the interferometer, but is also inherently improved by a factor of square root of two. Unfortunately, practical applications of Q-OCT are hindered by image-scrambling artefacts and slow acquisition times. Here, we present a theoretical analysis of a novel approach that is free of these problems: Q-OCT with joint spectrum detection (JS-Q-OCT). Based on a photon pair coincidence detection as in the standard Q-OCT configuration, it also discerns, each photon pair by their wavelength. We show that all the information about the internal structures of the object is encoded in the joint spectrum and can be easily retrieved through Fourier transformation. No depth scanning is required, making our technique potentially faster than standard Q-OCT. Finally, we show that the data available in the joint spectrum enables artefact removal and discuss prospective algorithms for doing so.
Open AccessQuantum Optical Coherence Tomography using two photon joint spectrum detection (JS-Q-OCT)
Quantum Optical Coherence Tomography (Q-OCT) is the non-classical counterpart of Optical Coherence Tomography (OCT) - a high-resolution 3D imaging technique based on white-light interferometry. Because Q-OCT uses a source of frequency-entangled photon pairs, not only is the axial resolution not affected by dispersion mismatch in the interferometer, but is also inherently improved by a factor of square root of two. Unfortunately, practical applications of Q-OCT are hindered by image-scrambling artefacts and slow acquisition times. Here, we present a theoretical analysis of a novel approach that is free of these problems: Q-OCT with joint spectrum detection (JS-Q-OCT). Based on a photon pair coincidence detection as in the standard Q-OCT configuration, it also discerns, each photon pair by their wavelength. We show that all the information about the internal structures of the object is encoded in the joint spectrum and can be easily retrieved through Fourier transformation. No depth scanning is required, making our technique potentially faster than standard Q-OCT. Finally, we show that the data available in the joint spectrum enables artefact removal and discuss prospective algorithms for doing so.